메뉴 건너뛰기




Volumn 30, Issue 3, 2014, Pages 485-494

Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: Comparison with intravascular ultrasound-derived reconstructions

Author keywords

Bioresorbable scaffold; Endothelial shear stress; Neointimal formation; Optical coherence tomography

Indexed keywords

ADULT; ANGIOCARDIOGRAPHY; ANGIOGRAPHY DEVICE; ARTERIAL WALL THICKNESS; ARTICLE; BIORESORBABLE SCAFFOLD; BIORESORBABLE VASCULAR SCAFFOLD; BLOOD FLOW; CATHETER; CORONARY ARTERY DISEASE; ENDOTHELIAL SHEAR STRESS; FEMALE; FOLLOW UP; HUMAN; IMAGE RECONSTRUCTION; IMAGING; INTRAVASCULAR ULTRASOUND; INTRAVASCULAR ULTRASOUND SYSTEM; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; NEOINTIMA; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL COHERENCE TOMOGRAPHY DEVICE; PROSPECTIVE STUDY; SHEAR STRESS; SIMULATION; BIODEGRADABLE IMPLANT; BIOPROSTHESIS; CLINICAL TRIAL; COHORT ANALYSIS; COMPARATIVE STUDY; ECHOGRAPHY; ENDOSCOPIC ECHOGRAPHY; EVALUATION STUDY; MECHANICAL STRESS; MIDDLE AGED; PROCEDURES; PROSTHESIS; RADIOGRAPHY; REPRODUCIBILITY; STENT; TISSUE SCAFFOLD; TREATMENT OUTCOME; VASCULAR ENDOTHELIUM;

EID: 84899105915     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-014-0374-3     Document Type: Article
Times cited : (39)

References (22)
  • 2
    • 78449244724 scopus 로고    scopus 로고
    • The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans
    • doi:10.1016/j.jcin.2010.08.018
    • Papafaklis MI, Bourantas CV, Theodorakis PE, Katsouras CS, Naka KK, Fotiadis DI, Michalis LK (2010) The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans. JACC Cardiovasc Interv 3(11):1181-1189. doi:10.1016/j.jcin.2010.08.018
    • (2010) JACC Cardiovasc Interv , vol.3 , Issue.11 , pp. 1181-1189
    • Papafaklis, M.I.1    Bourantas, C.V.2    Theodorakis, P.E.3    Katsouras, C.S.4    Naka, K.K.5    Fotiadis, D.I.6    Michalis, L.K.7
  • 3
    • 41149135557 scopus 로고    scopus 로고
    • Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus
    • doi:10.1007/s10554-007-9274-
    • Suzuki N, Nanda H, Angiolillo DJ, Bezerra H, Sabate M, Jimenez-Quevedo P, Alfonso F, Macaya C, Bass TA, Ilegbusi OJ, Costa MA (2008) Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus. Int J Cardiovasc Imaging 24(4):357-364. doi:10.1007/s10554- 007-9274-
    • (2008) Int J Cardiovasc Imaging , vol.24 , Issue.4 , pp. 357-364
    • Suzuki, N.1    Nanda, H.2    Angiolillo, D.J.3    Bezerra, H.4    Sabate, M.5    Jimenez-Quevedo, P.6    Alfonso, F.7    Macaya, C.8    Bass, T.A.9    Ilegbusi, O.J.10    Costa, M.A.11
  • 4
    • 0035799342 scopus 로고    scopus 로고
    • Relationship between neointimal thickness and shear stress after wallstent implantation in human coronary arteries
    • Wentzel JJ, Krams R, Schuurbiers JC, Oomen JA, Kloet J, van Der Giessen WJ, Serruys PW, Slager CJ (2001) Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries. Circulation 103(13):1740-1745 (Pubitemid 32291410)
    • (2001) Circulation , vol.103 , Issue.13 , pp. 1740-1745
    • Wentzel, J.J.1    Krams, R.2    Schuurbiers, J.C.H.3    Oomen, J.A.4    Kloet, J.5    Van Der, G.W.J.6    Serruys, P.W.7    Slager, C.J.8
  • 5
    • 50849143477 scopus 로고    scopus 로고
    • Optical coherence tomography: High resolution intravascular imaging to evaluate vascular healing after coronary stenting
    • doi:10.1002/ccd.21606
    • Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72(2):237-247. doi:10.1002/ccd.21606
    • (2008) Catheter Cardiovasc Interv , vol.72 , Issue.2 , pp. 237-247
    • Guagliumi, G.1    Sirbu, V.2
  • 10
    • 84884737180 scopus 로고    scopus 로고
    • A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: Implications for widespread assessment of endothelial shear stress in humans
    • doi:10.4244/EIJV9I5A94
    • Bourantas CV, Papafaklis MI, Athanasiou L, Kalatzis FG, Naka KK, Siogkas PK, Takahashi S, Saito S, Fotiadis DI, Feldman CL, Stone PH, Michalis LK (2013) A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans. EuroIntervention 9(5):582-93. doi:10.4244/EIJV9I5A94
    • (2013) EuroIntervention , vol.9 , Issue.5 , pp. 582-593
    • Bourantas, C.V.1    Papafaklis, M.I.2    Athanasiou, L.3    Kalatzis, F.G.4    Naka, K.K.5    Siogkas, P.K.6    Takahashi, S.7    Saito, S.8    Fotiadis, D.I.9    Feldman, C.L.10    Stone, P.H.11    Michalis, L.K.12
  • 11
    • 64149107846 scopus 로고    scopus 로고
    • Relationship of shear stress with instent restenosis: Baremetal stenting and the effect of brachytherapy
    • doi:10.1016/j.ijcard.2008.02.006
    • Papafaklis MI, Bourantas CV, Theodorakis PE, Katsouras CS, Fotiadis DI, Michalis LK (2009) Relationship of shear stress with instent restenosis: baremetal stenting and the effect of brachytherapy. Int J Cardiol 134(1):25-32. doi:10.1016/j.ijcard.2008.02.006
    • (2009) Int J Cardiol , vol.134 , Issue.1 , pp. 25-32
    • Papafaklis, M.I.1    Bourantas, C.V.2    Theodorakis, P.E.3    Katsouras, C.S.4    Fotiadis, D.I.5    Michalis, L.K.6
  • 14
    • 23644444112 scopus 로고    scopus 로고
    • Blood flow in stented arteries: A parametric comparison of strut design patterns in three dimensions
    • DOI 10.1115/1.1934122
    • He Y, Duraiswamy N, Frank AO, Moore JE Jr (2005) Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng 127(4):637-647 (Pubitemid 41116923)
    • (2005) Journal of Biomechanical Engineering , vol.127 , Issue.4 , pp. 637-647
    • He, Y.1    Duraiswamy, N.2    Frank, A.O.3    Moore Jr., J.E.4
  • 15
    • 40249089858 scopus 로고    scopus 로고
    • Effects of different stent designs on local hemodynamics in stented arteries
    • doi:10.1016/j.jbiomech.2007.12.005
    • Balossino R, Gervaso F, Migliavacca F, Dubini G (2008) Effects of different stent designs on local hemodynamics in stented arteries. J Biomech 41(5):1053-1061. doi:10.1016/j.jbiomech.2007.12.005
    • (2008) J Biomech , vol.41 , Issue.5 , pp. 1053-1061
    • Balossino, R.1    Gervaso, F.2    Migliavacca, F.3    Dubini, G.4
  • 16
    • 68149150511 scopus 로고    scopus 로고
    • Comparison of near-wall hemodynamic parameters in stented artery models
    • doi:10.1115/1.3118764
    • Duraiswamy N, Schoephoerster RT, Moore JE Jr (2009) Comparison of near-wall hemodynamic parameters in stented artery models. J Biomech Eng 131(6):061006. doi:10.1115/1.3118764
    • (2009) J Biomech Eng , vol.131 , Issue.6 , pp. 061006
    • Duraiswamy, N.1    Schoephoerster, R.T.2    Moore Jr., J.E.3
  • 17
    • 70349579182 scopus 로고    scopus 로고
    • Hemodynamically driven stent strut design
    • doi:10.1007/s10439-009-9719-9
    • Jimenez JM, Davies PF (2009) Hemodynamically driven stent strut design. Ann Biomed Eng 37(8):1483-1494. doi:10.1007/s10439-009-9719-9
    • (2009) Ann Biomed Eng , vol.37 , Issue.8 , pp. 1483-1494
    • Jimenez, J.M.1    Davies, P.F.2
  • 18
    • 67650708197 scopus 로고    scopus 로고
    • Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments
    • doi:10.1186/1475-925X-8-8
    • Mejia J, Ruzzeh B, Mongrain R, Leask R, Bertrand OF (2009) Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments. Biomed Eng Online 8:8. doi:10.1186/1475-925X-8-8
    • (2009) Biomed Eng Online , vol.8 , pp. 8
    • Mejia, J.1    Ruzzeh, B.2    Mongrain, R.3    Leask, R.4    Bertrand, O.F.5
  • 19
    • 14144250735 scopus 로고    scopus 로고
    • Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models
    • doi:10.1152/japplphysiol.0 0872.2004
    • LaDisa JF Jr, Olson LE, Guler I, Hettrick DA, Kersten JR, Warltier DC, Pagel PS (2005) Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. J Appl Physiol 98(3):947-957. doi:10.1152/japplphysiol.0 0872.2004
    • (2005) J Appl Physiol , vol.98 , Issue.3 , pp. 947-957
    • LaDisa Jr., J.F.1    Olson, L.E.2    Guler, I.3    Hettrick, D.A.4    Kersten, J.R.5    Warltier, D.C.6    Pagel, P.S.7
  • 20
    • 77952009983 scopus 로고    scopus 로고
    • The influence of strut-connectors in stented vessels: A comparison of pulsatile flow through five coronary stents
    • doi:10.1007/s10439-010-9962-0
    • Pant S, Bressloff NW, Forrester AI, Curzen N (2010) The influence of strut-connectors in stented vessels: a comparison of pulsatile flow through five coronary stents. Ann Biomed Eng 38(5):1893-1907. doi:10.1007/s10439-010-9962-0
    • (2010) Ann Biomed Eng , vol.38 , Issue.5 , pp. 1893-1907
    • Pant, S.1    Bressloff, N.W.2    Forrester, A.I.3    Curzen, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.