메뉴 건너뛰기




Volumn 96, Issue , 2014, Pages 220-223

Automated isotope dilution liquid chromatography-tandem mass spectrometry with on-line dilution and solid phase extraction for the measurement of cortisol in human serum sample

Author keywords

Cortisol; Isotope dilution mass spectrometry; Liquid chromatography tandem mass spectrometry (LC MS MS); On line dilution; On line solid phase extraction (SPE)

Indexed keywords

HYDROCORTISONE; METHANOL; ISOTOPE;

EID: 84899072745     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2014.03.015     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 1242316209 scopus 로고    scopus 로고
    • Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry
    • Tai S.S.-C., Welch M.J. Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. Anal. Chem. 2004, 76:1008-1014.
    • (2004) Anal. Chem. , vol.76 , pp. 1008-1014
    • Tai, S.S.-C.1    Welch, M.J.2
  • 2
    • 0028829445 scopus 로고
    • 3 routine methods for serum cortisol evaluated by comparison with an isotope-dilution gas-chromatography mass-spectrometry method
    • De Brabandere V.I., Veronique I., Thienpont L.M., Stöckl D., De Leenheer A.P. 3 routine methods for serum cortisol evaluated by comparison with an isotope-dilution gas-chromatography mass-spectrometry method. Clin. Chem. 1995, 41:1781-1783.
    • (1995) Clin. Chem. , vol.41 , pp. 1781-1783
    • De Brabandere, V.I.1    Veronique, I.2    Thienpont, L.M.3    Stöckl, D.4    De Leenheer, A.P.5
  • 4
    • 0020540170 scopus 로고
    • External quality assessment of assays for cortisol in plasma: use of target data obtained by gas chromatography/mass spectrometry
    • Gaskell S.J., Collins C.J., Thorne G.C., Groom G.V. External quality assessment of assays for cortisol in plasma: use of target data obtained by gas chromatography/mass spectrometry. Clin. Chem. 1983, 29:862-867.
    • (1983) Clin. Chem. , vol.29 , pp. 862-867
    • Gaskell, S.J.1    Collins, C.J.2    Thorne, G.C.3    Groom, G.V.4
  • 6
    • 0030058559 scopus 로고    scopus 로고
    • Candidate reference method for determining serum cortisol based on isotope dilution-gas chromatography/mass spectrometry using heptafluorobutyrilation as derivatization method
    • Thienpont L.M., Veronique I., De Brabandere V.I., Stöckl D., De Leenheer A.P. Candidate reference method for determining serum cortisol based on isotope dilution-gas chromatography/mass spectrometry using heptafluorobutyrilation as derivatization method. Anal. Biochem. 1996, 234:204-209.
    • (1996) Anal. Biochem. , vol.234 , pp. 204-209
    • Thienpont, L.M.1    Veronique, I.2    De Brabandere, V.I.3    Stöckl, D.4    De Leenheer, A.P.5
  • 7
    • 71749097611 scopus 로고    scopus 로고
    • Development of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry
    • Kawaguchi M., Takatsu A. Development of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry. Anal. Sci. 2009, 25:989-992.
    • (2009) Anal. Sci. , vol.25 , pp. 989-992
    • Kawaguchi, M.1    Takatsu, A.2
  • 8
    • 11244340625 scopus 로고    scopus 로고
    • Determination of serum cortisol using isotope dilution-liquid chromatography-mass spectrometry as a candidate reference method
    • Jung P.G., Kim B., Park S.-R., So H.-Y., Shi L.H., Kim Y. Determination of serum cortisol using isotope dilution-liquid chromatography-mass spectrometry as a candidate reference method. Anal. Bioanal. Chem. 2004, 380:782-788.
    • (2004) Anal. Bioanal. Chem. , vol.380 , pp. 782-788
    • Jung, P.G.1    Kim, B.2    Park, S.-R.3    So, H.-Y.4    Shi, L.H.5    Kim, Y.6
  • 9
    • 0032858854 scopus 로고    scopus 로고
    • Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography
    • Hennion M.C. Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography. J. Chromatogr. A 1999, 856:3-54.
    • (1999) J. Chromatogr. A , vol.856 , pp. 3-54
    • Hennion, M.C.1
  • 10
    • 23744507267 scopus 로고    scopus 로고
    • Automated on-line column- switching HPLC-MS/MS method with peak focusing for the determination of nine environmental phenols in urine
    • Ye X., Kuklenyik Z., Needham L.L., Calafat A.M. Automated on-line column- switching HPLC-MS/MS method with peak focusing for the determination of nine environmental phenols in urine. Anal. Chem. 2005, 77:5407-5413.
    • (2005) Anal. Chem. , vol.77 , pp. 5407-5413
    • Ye, X.1    Kuklenyik, Z.2    Needham, L.L.3    Calafat, A.M.4
  • 11
    • 49849083844 scopus 로고    scopus 로고
    • On-line liquid chromatography-mass spectrometry with dilution line to achieve large volume urine injection for the improvement of sensitivity
    • Liu M., Yan W., Lin J.-M., Hashi Y., Liu L., Wei Y. On-line liquid chromatography-mass spectrometry with dilution line to achieve large volume urine injection for the improvement of sensitivity. J. Chromatogr. A 2008, 1198-1199:87-94.
    • (2008) J. Chromatogr. A , pp. 87-94
    • Liu, M.1    Yan, W.2    Lin, J.-M.3    Hashi, Y.4    Liu, L.5    Wei, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.