메뉴 건너뛰기




Volumn , Issue , 2007, Pages

Sensitive, real-time interband cascade laser based sensor for ethane monitoring

Author keywords

[No Author keywords available]

Indexed keywords

ETHANE; MOLECULAR SPECTROSCOPY; SEMICONDUCTOR LASERS;

EID: 84899031525     PISSN: None     EISSN: 21622701     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 1
    • 0029168316 scopus 로고
    • The Tropospheric distribution and budget of ethane
    • J. Rudolph, "The Tropospheric distribution and budget of ethane", J. Geophys. Res., 100, 11369-11381 (1995).
    • (1995) J. Geophys. Res. , vol.100 , pp. 11369-11381
    • Rudolph, J.1
  • 2
    • 0033589866 scopus 로고    scopus 로고
    • Northern and Southern hemisphere ground-based infrared spectroscopic measurements of tropospheric carbon monoxide and ethane
    • C.P. Rinsland, N.B. Jones, B.J. Connor, et al., Northern and Southern hemisphere ground-based infrared spectroscopic measurements of tropospheric carbon monoxide and ethane", J. Geophys. Res., 103, 28197-28217 (1998).
    • (1998) J. Geophys. Res. , vol.103 , pp. 28197-28217
    • Rinsland, C.P.1    Jones, N.B.2    Connor, B.J.3
  • 3
    • 0037283927 scopus 로고    scopus 로고
    • Laser-based trace gas detection of ethane as a result of photo-oxidative damage in chilled cucumber leaves (Invited)
    • I.E. Santosa, L.J.J. Laarhoven, J. Harbinson, S. Driscoll, F. J. M. Harren, "Laser-based trace gas detection of ethane as a result of photo-oxidative damage in chilled cucumber leaves (Invited)", Review of Scientific Instruments, 74, 680-683 (2003).
    • (2003) Review of Scientific Instruments , vol.74 , pp. 680-683
    • Santosa, I.E.1    Laarhoven, L.J.J.2    Harbinson, J.3    Driscoll, S.4    Harren, F.J.M.5
  • 7
    • 0028090710 scopus 로고
    • Evidence for free radical-mediated lipid peroxidation at reperfusion of human orthotopic liver transplants
    • T.H. Risby, W. Maley, R.P. Scott, et al., "Evidence for free radical-mediated lipid peroxidation at reperfusion of human orthotopic liver transplants." Surgery, 115, 94-101 (1994).
    • (1994) Surgery , vol.115 , pp. 94-101
    • Risby, T.H.1    Maley, W.2    Scott, R.P.3
  • 9
    • 1942424116 scopus 로고    scopus 로고
    • Parts per trillion sensitivity for ethane in air with an optical parametric cavity leak-out spectrometer
    • G. von Basum, D. Halmer, P. Hering, M. Muertz, S. Schiller, F. Mueller, A. Popp, and F. Kuehnemann, "Parts per trillion sensitivity for ethane in air with an optical parametric cavity leak-out spectrometer", Opt. Lett., 29, 797-799 (2004).
    • (2004) Opt. Lett. , vol.29 , pp. 797-799
    • von Basum, G.1    Halmer, D.2    Hering, P.3    Muertz, M.4    Schiller, S.5    Mueller, F.6    Popp, A.7    Kuehnemann, F.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.