Volumn 213, Issue , 2014, Pages 1-8

Design and implementation of an industrial C4D sensor for conductivity detection

Author keywords

Contactless conductivity detection; Fluid; Series resonance; Shield configuration

Indexed keywords

CAPACITANCE; EXPERIMENTS; FLUIDS; INDUSTRIAL APPLICATIONS; INDUSTRY;

EID: 84898929709     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2014.03.024     Document Type: Article
Times cited : (13)

References (24)
  • 3
    • 0035150587 scopus 로고    scopus 로고
    • Application of the electrical conductivity of concentrated electrolyte solutions to industrial process control and design: From experimental measurement towards prediction through modelling
    • DOI 10.1016/S0165-9936(00)00081-9, PII S0165993600000819
    • A. de Diego, A. Usobiaga, L.A. Fernandez, and J.M. Madariaga Application of the electrical conductivity of concentrated electrolyte solutions to industrial process control and design: from experimental measurement towards prediction through modeling Trends Anal. Chem. 20 2001 65 78 (Pubitemid 32124870)
    • (2001) TrAC - Trends in Analytical Chemistry , vol.20 , Issue.2 , pp. 65-78
    • De Diego, A.1    Usobiaga, A.2    Fernandez, L.A.3    Madariaga, J.M.4
  • 4
    • 0036811393 scopus 로고    scopus 로고
    • Optimization of the high-frequency contactless conductivity detector for capillary electrophoresis
    • DOI 10.1002/1522-2683(200210)23:20<3520::AID-ELPS3520>3.0.CO;2-G
    • B. Gas, J. Zuska, P. Coufal, and T. van de Goor Optimization of the high-frequency contactless conductivity detector for capillary electrophoresis Electrophoresis 23 2002 3520 3527 (Pubitemid 35363895)
    • (2002) Electrophoresis , vol.23 , Issue.20 , pp. 3520-3527
    • Gas, B.1    Zuska, J.2    Coufal, P.3    Van De Goor, T.4
  • 5
    • 37449034019 scopus 로고    scopus 로고
    • A review of the recent achievements in capacitively coupled contactless conductivity detection
    • DOI 10.1016/j.aca.2007.11.045, PII S0003267007019587
    • P. Kuban, and P.C. Hauser A review of the recent achievements in capacitively coupled contactless conductivity detection Anal. Chim. Acta 607 2008 15 29 (Pubitemid 50012737)
    • (2008) Analytica Chimica Acta , vol.607 , Issue.1 , pp. 15-29
    • Kuban, P.1    Hauser, P.C.2
  • 6
    • 0019152921 scopus 로고
    • High frequency contactless conductivity detection in isotachophoresis
    • B. Gas, M. Demjanenko, and J. Vacik High-frequency contactless conductivity detection in isotachophoresis J. Chromatogr. 192 1980 253 257 (Pubitemid 10054184)
    • (1980) Journal of Chromatography , vol.192 , Issue.2 , pp. 253-257
    • Gas, B.1    Demjanenko, M.2    Vacik, J.3
  • 7
    • 0000776775 scopus 로고    scopus 로고
    • Contactless conductivity detection for capillary electrophoresis
    • A.J. Zemann, E. Schnell, D. Volgger, and G.K. Bonn Contactless conductivity detection for capillary electrophoresis Anal. Chem. 70 1998 563 567
    • (1998) Anal. Chem. , vol.70 , pp. 563-567
    • Zemann, A.J.1    Schnell, E.2    Volgger, D.3    Bonn, G.K.4
  • 8
    • 0542397711 scopus 로고    scopus 로고
    • An oscillometric detector for capillary electrophoresis
    • J.A.F. da Silva, and C.L. do Lago An oscillometric detector for capillary electrophoresis Anal. Chem. 70 1998 4339 4343
    • (1998) Anal. Chem. , vol.70 , pp. 4339-4343
    • Da Silva, J.A.F.1    Do Lago, C.L.2
  • 9
    • 0037178383 scopus 로고    scopus 로고
    • Application of a contactless conductometric detector for the simultaneous determination of small anions and cations by capillary electrophoresis with dual-opposite end injection
    • DOI 10.1016/S0021-9673(02)00656-8, PII S0021967302006568
    • P. Kuban, B. Karlberg, P. Kuban, and V. Kuban Application of a contactless conductometric detector for the simultaneous determination of small anions and cations by capillary electrophoresis with dual-opposite end injection J. Chromatogr. A 964 2002 227 241 (Pubitemid 34718020)
    • (2002) Journal of Chromatography A , vol.964 , Issue.1-2 , pp. 227-241
    • Kuban, P.1    Karlberg, B.2    Kuba, P.3    Kuba, V.4
  • 10
    • 50149093106 scopus 로고    scopus 로고
    • A resonance-induced sensitivity enhancement method for conductivity sensors
    • EXCO, Daegu, Korea, October 22-25
    • C.-Y. Shih, W. Li, S.Y. Zheng, and Y.-C. Tai A resonance-induced sensitivity enhancement method for conductivity sensors Proceedings of Fifth IEEE Conference on Sensors EXCO, Daegu, Korea, October 22-25 2006 271 274
    • (2006) Proceedings of Fifth IEEE Conference on Sensors , pp. 271-274
    • Shih, C.-Y.1    Li, W.2    Zheng, S.Y.3    Tai, Y.-C.4
  • 11
    • 9144259579 scopus 로고    scopus 로고
    • Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part I: Frequency behavior and cell geometry
    • DOI 10.1002/elps.200406059
    • P. Kuban, and P.C. Hauser Fundamental aspects of contactless conductivity detection for capillary electrophoresis, Part I. Frequency behavior and cell geometry Electrophoresis 25 2004 3387 3397 (Pubitemid 39545255)
    • (2004) Electrophoresis , vol.25 , Issue.20 , pp. 3387-3397
    • Kuban, P.1    Hauser, P.C.2
  • 12
    • 9144231964 scopus 로고    scopus 로고
    • Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part II: Signal-to-noise ratio and stray capacitance
    • DOI 10.1002/elps.200406060
    • P. Kuban, and P.C. Hauser Fundamental aspects of contactless conductivity detection for capillary electrophoresis, Part II. Signal-to-noise ratio and stray capacitance Electrophoresis 25 2004 3398 3405 (Pubitemid 39545256)
    • (2004) Electrophoresis , vol.25 , Issue.20 , pp. 3398-3405
    • Kuban, P.1    Hauser, P.C.2
  • 13
    • 36549062555 scopus 로고    scopus 로고
    • Contactless conductivity detection for microfluidics: Designs and applications
    • DOI 10.1016/j.talanta.2007.05.058, PII S0039914007005255, Micro- and Nanotechnology in Electrochemical Detection Science - dedicated to Professor Joseph Wang on the occasion of his 60th birthday MNED 2007 SI
    • M. Pumera Contactless conductivity detection for microfluidics: designs and applications Talanta 74 2007 358 364 (Pubitemid 350192527)
    • (2007) Talanta , vol.74 , Issue.3 , pp. 358-364
    • Pumera, M.1
  • 14
    • 60949109716 scopus 로고    scopus 로고
    • Ten years of axial capacitively coupled contactless conductivity detection for CZE - A review
    • P. Kuban, and P.C. Hauser Ten years of axial capacitively coupled contactless conductivity detection for CZE - a review Electrophoresis 30 2008 176 188
    • (2008) Electrophoresis , vol.30 , pp. 176-188
    • Kuban, P.1    Hauser, P.C.2
  • 15
    • 71849106681 scopus 로고    scopus 로고
    • A new method of capacitively coupled contactless conductivity detection based on series resonance
    • Z.Y. Huang, W.W. Jiang, X.M. Zhou, B.L. Wang, H.F. Ji, and H.Q. Li A new method of capacitively coupled contactless conductivity detection based on series resonance Sens. Actuators, B: Chem. 143 2009 239 245
    • (2009) Sens. Actuators, B: Chem. , vol.143 , pp. 239-245
    • Huang, Z.Y.1    Jiang, W.W.2    Zhou, X.M.3    Wang, B.L.4    Ji, H.F.5    Li, H.Q.6
  • 16
    • 78650280038 scopus 로고    scopus 로고
    • Capacitively coupled contactless conductivity detection for microseparation techniques - Recent developments
    • P. Kuban, and P.C. Hauser Capacitively coupled contactless conductivity detection for microseparation techniques - recent developments Electrophoresis 32 2011 30 42
    • (2011) Electrophoresis , vol.32 , pp. 30-42
    • Kuban, P.1    Hauser, P.C.2
  • 17
    • 0036863536 scopus 로고    scopus 로고
    • A contactless conductivity detector for capillary electrophoresis: Effects of the detection cell geometry on the detector performance
    • DOI 10.1002/1522-2683(200211)23:21<3718::AID-ELPS3718>3.0.CO;2-U
    • P. Tuma, F. Opekar, and K. Stulik A contactless conductivity detector for capillary electrophoresis: effects of the detection cell geometry on the detector performance Electrophoresis 23 2002 3718 3724 (Pubitemid 35469555)
    • (2002) Electrophoresis , vol.23 , Issue.21 , pp. 3718-3724
    • Tuma, P.1    Opekar, F.2    Stulik, K.3
  • 18
    • 0033199254 scopus 로고    scopus 로고
    • Capillary electrophoresis and contactless conductivity detection of ions in narrow inner diameter capillaries
    • K. Mayrhofer, A.J. Zemann, E. Schnell, and G.K. Bonn Capillary electrophoresis and contactless conductivity detection of ions in narrow inner diameter capillaries Anal. Chem. 71 1999 3828 3833
    • (1999) Anal. Chem. , vol.71 , pp. 3828-3833
    • Mayrhofer, K.1    Zemann, A.J.2    Schnell, E.3    Bonn, G.K.4
  • 19
    • 0037086153 scopus 로고    scopus 로고
    • Design of an electronic interface for capacitively coupled four-electrode conductivity detection in capillary electrophoresis microchip
    • DOI 10.1016/S0925-4005(01)01051-6, PII S0925400501010516
    • F. Laugere, G.W. Lubking, J. Bastemeijer, and M.J. Vellekoop Design of an electronic interface for capacitively coupled four-electrode conductivity detection in capillay electrophoresisi microchip Sens. Actuators, B: Chem. 83 2002 104 108 (Pubitemid 34232233)
    • (2002) Sensors and Actuators, B: Chemical , vol.83 , Issue.1-3 , pp. 104-108
    • Laugere, F.1    Lubking, G.W.2    Bastemeijer, J.3    Vellekoop, M.J.4
  • 20
    • 0035426096 scopus 로고    scopus 로고
    • Downscaling aspects of a conductivity detector for application in on-chip capillary electrophoresis
    • DOI 10.1016/S0924-4247(01)00547-7, PII S0924424701005477
    • F. Laugere, G.W. Lubking, J. Bastemeijer, and M.J. Vellekoop Downscaling aspects of a conductivity detector for application in on-chip calillary electrophoresis Sens. Actuators, A: Phys. 92 2001 109 114 (Pubitemid 32697885)
    • (2001) Sensors and Actuators, A: Physical , vol.92 , Issue.1-3 , pp. 109-114
    • Laugere, F.1    Lubking, G.W.2    Berthold, A.3    Bastemeijer, J.4    Vellekoop, M.J.5
  • 21
    • 47749096016 scopus 로고    scopus 로고
    • Development of a contactless conductivity detector cell for 1.6 mm O.D. (1/16th inch) HPLC tubing and micro-bore columns with on-column detection
    • DOI 10.1039/b803038c
    • E. Gillespie, D. Connolly, M. Macka, P. Hauser, and B. Paull Development of a contactless conductivity detector cell for 1.6 mm OD (1/16th inch) HPLC tubing and micro-bore columns with on-column detection Analyst 133 2008 1104 1110 (Pubitemid 352033092)
    • (2008) Analyst , vol.133 , Issue.8 , pp. 1104-1110
    • Gillespie, E.1    Connolly, D.2    Macka, M.3    Hauser, P.4    Paull, B.5
  • 22
    • 84865963078 scopus 로고    scopus 로고
    • Desigen of capacitively coupled contactless conductivity detection sensor
    • Z.Y. Huang, J. long, W.B. Xu, H.F. Ji, B.L. Wang, and H.Q. Li Desigen of capacitively coupled contactless conductivity detection sensor Flow Meas. Instrum. 27 2012 67 70
    • (2012) Flow Meas. Instrum. , vol.27 , pp. 67-70
    • Huang, Z.Y.1    Long, J.2    Xu, W.B.3    Ji, H.F.4    Wang, B.L.5    Li, H.Q.6
  • 23
    • 77957680387 scopus 로고    scopus 로고
    • A capacitive sensor system for the analysis of two-phase flows of oil and conductive water
    • M. Demori, V. Ferrari, D. Strazza, and P. Poesio A capacitive sensor system for the analysis of two-phase flows of oil and conductive water Sens. Actuators, A: Phys. 163 2010 172 179
    • (2010) Sens. Actuators, A: Phys. , vol.163 , pp. 172-179
    • Demori, M.1    Ferrari, V.2    Strazza, D.3    Poesio, P.4
  • 24
    • 80052841250 scopus 로고    scopus 로고
    • Capacitance sensor for hold-up measurement in high-viscous-oil/ conductive-water core-annular flows
    • D. Strazza, M. Demori, V. Ferrari, and P. Poesio Capacitance sensor for hold-up measurement in high-viscous-oil/conductive-water core-annular flows Flow Meas. Instrum. 22 2011 360 369
    • (2011) Flow Meas. Instrum. , vol.22 , pp. 360-369
    • Strazza, D.1    Demori, M.2    Ferrari, V.3    Poesio, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.