메뉴 건너뛰기




Volumn 198, Issue , 2014, Pages 388-394

Simultaneous voltammetric determination of dihydroxybenzene isomers at single-walled carbon nanohorn modified glassy carbon electrode

Author keywords

Accumulation; Dihydroxybenzene isomers; Electrochemistry; Simultaneous determination; Single walled carbon nanohorns

Indexed keywords

ANODIC OXIDATION; CARBON NANOTUBES; ELECTROCHEMISTRY; GLASS; GLASS MEMBRANE ELECTRODES; NANOHORNS; PHENOLS;

EID: 84898857242     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.03.082     Document Type: Article
Times cited : (39)

References (28)
  • 1
    • 20444477617 scopus 로고    scopus 로고
    • Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    • H.L. Qi, and C.X. Zhang Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes Electroanalysis 17 2005 832 838
    • (2005) Electroanalysis , vol.17 , pp. 832-838
    • Qi, H.L.1    Zhang, C.X.2
  • 2
    • 0032854903 scopus 로고    scopus 로고
    • Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection
    • DOI 10.1016/S0021-9673(99)00670-6, PII S0021967399006706
    • H. Cui, C.X. He, and G.W. Zhao Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection J. Chromatogr. A 855 1999 171 179 (Pubitemid 29413096)
    • (1999) Journal of Chromatography A , vol.855 , Issue.1 , pp. 171-179
    • Cui, H.1    He, C.2    Zhao, G.3
  • 3
    • 0037458496 scopus 로고    scopus 로고
    • Determination of major phenolic compounds in water by reversed-phase liquid chromatrography after pre-column derivation with benzoyl chloride
    • A. Asan, and I. Isildak Determination of major phenolic compounds in water by reversed-phase liquid chromatrography after pre-column derivation with benzoyl chloride J. Chromatogr. A 988 2003 145 149
    • (2003) J. Chromatogr. A , vol.988 , pp. 145-149
    • Asan, A.1    Isildak, I.2
  • 4
    • 0035017412 scopus 로고    scopus 로고
    • A new sensitive and selective spectrophotometric method for the determination of catechol derivatives and its pharmaceutical preparations
    • DOI 10.1016/S0731-7085(00)00504-5, PII S0731708500005045
    • P. Nagarajia, R.A. Vasantha, and K.R. Sunitha A new sensitive and selective spectrometric method for the determination of catechol derivatives and its pharmaceutical preparations J. Pharm. Biomed. Anal. 25 2001 417 424 (Pubitemid 32493898)
    • (2001) Journal of Pharmaceutical and Biomedical Analysis , vol.25 , Issue.3-4 , pp. 417-424
    • Nagaraja, P.1    Vasantha, R.A.2    Sunitha, K.R.3
  • 5
    • 33745003897 scopus 로고    scopus 로고
    • Determination of phenol, resorcinol and hydroquinone in air samples by synchronous fluorescence using partial least-squares (PLS)
    • DOI 10.1016/j.talanta.2005.12.050, PII S0039914006000154
    • M.F. Pistonesi, M.S.D. Nezio, M.E. Centurión, M.E. Palomeque, A.G. Lista, and B.S.F. Band Determination of phenol, resorcinol and hydroquinone in air samples by synchronous fluorescence using partial least-squares (PLS) Talanta 69 2006 1265 1268 (Pubitemid 43866182)
    • (2006) Talanta , vol.69 , Issue.5 , pp. 1265-1268
    • Pistonesi, M.F.1    Di Nezio, M.S.2    Centurion, M.E.3    Palomeque, M.E.4    Lista, A.G.5    Fernandez Band, B.S.6
  • 6
    • 2942517695 scopus 로고    scopus 로고
    • Electrochemical sensors
    • DOI 10.1021/ac049580z
    • E. Bakker Electrochemical sensors Anal. Chem. 76 2004 3285 3298 (Pubitemid 38747271)
    • (2004) Analytical Chemistry , vol.76 , Issue.12 , pp. 3285-3298
    • Bakker, E.1
  • 7
    • 41549120541 scopus 로고    scopus 로고
    • Voltammetric determination of dihydroxybenzenes at a mechanically renewed electrode made from a graphite-epoxy composite
    • DOI 10.1007/s10809-008-3012-1
    • L.I. Skvortsova, V.N. Kiryushov, T.P. Aleksandrova, and O.V. Karunina Voltammtric determination of dihydrobenzenes at a mechanically renewed electrode made from a graphite-epoxy composite J. Anal. Chem. 63 2008 258 264 (Pubitemid 351464376)
    • (2008) Journal of Analytical Chemistry , vol.63 , Issue.3 , pp. 258-264
    • Skvortsova, L.I.1    Kiryushov, V.N.2    Aleksandrova, T.P.3    Karunina, O.V.4
  • 8
    • 34347355499 scopus 로고    scopus 로고
    • Electrochemical determination of dihydroxybenzene isomers at the carbon-atom-wire-modified electrode
    • K.H. Xue, W. Xu, and S.Y. Yin Electrochemical determination of dihydroxybenzene isomers at the carbon-atom-wire-modified electrode J. Electrochem. Soc. 154 2007 F147 F151
    • (2007) J. Electrochem. Soc. , vol.154
    • Xue, K.H.1    Xu, W.2    Yin, S.Y.3
  • 9
    • 58149508649 scopus 로고    scopus 로고
    • Simultaneous voltammetry determination of dihydroxybenzene isomers by nanogold modified electrode
    • L. Han, and X.L. Zhang Simultaneous voltammetry determination of dihydroxybenzene isomers by nanogold modified electrode Electroanalysis 21 2009 124 129
    • (2009) Electroanalysis , vol.21 , pp. 124-129
    • Han, L.1    Zhang, X.L.2
  • 10
    • 70849119419 scopus 로고    scopus 로고
    • Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode
    • J. Bai, L.P. Guo, J.C. Ndamanisha, and B. Qi Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode J. Appl. Electrochem. 39 2009 2497 2503
    • (2009) J. Appl. Electrochem. , vol.39 , pp. 2497-2503
    • Bai, J.1    Guo, L.P.2    Ndamanisha, J.C.3    Qi, B.4
  • 11
    • 11444260930 scopus 로고    scopus 로고
    • Direct simultaneous determination of dihyroxybeneze isomers at C-nanotube-modified electrodes by derivative voltammetry
    • Y.P. Ding, W.L. Liu, Q.S. Wu, and X.G. Wang Direct simultaneous determination of dihyroxybeneze isomers at C-nanotube-modified electrodes by derivative voltammetry J. Electroanal. Chem. 575 2005 275 280
    • (2005) J. Electroanal. Chem. , vol.575 , pp. 275-280
    • Ding, Y.P.1    Liu, W.L.2    Wu, Q.S.3    Wang, X.G.4
  • 12
    • 77951470841 scopus 로고    scopus 로고
    • Simultaneous determination of dihydroxybenzene isomers at MWCNTs/β-cyclodextrin modified carbon ionic liquid electrode in the presence of cetylpyridinium bromide
    • Q. Yu, Y. Liu, X.Y. Liu, X.D. Zeng, S.L. Luo, and W.Z. Wei Simultaneous determination of dihydroxybenzene isomers at MWCNTs/β-cyclodextrin modified carbon ionic liquid electrode in the presence of cetylpyridinium bromide Electroanalysis 22 2010 1012 1018
    • (2010) Electroanalysis , vol.22 , pp. 1012-1018
    • Yu, Q.1    Liu, Y.2    Liu, X.Y.3    Zeng, X.D.4    Luo, S.L.5    Wei, W.Z.6
  • 13
    • 77954932456 scopus 로고    scopus 로고
    • Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles
    • D.W. Li, Y.T. Li, W. Song, and Y.T. Long Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles Anal. Methods 2 2010 837 843
    • (2010) Anal. Methods , vol.2 , pp. 837-843
    • Li, D.W.1    Li, Y.T.2    Song, W.3    Long, Y.T.4
  • 14
    • 33847677974 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of dihydroxybenzene isomers using poly(acid chrome blue K)/carbon nanotube composite electrode
    • P.H. Yang, W.Z. Wei, and L. Yang Simultaneous voltammetric determination of dihydroxybenzene isomers using poly(acid chrome blue K)/carbon nanotube composite electrode Microchim. Acta 157 2007 229 235
    • (2007) Microchim. Acta , vol.157 , pp. 229-235
    • Yang, P.H.1    Wei, W.Z.2    Yang, L.3
  • 15
    • 34548119498 scopus 로고    scopus 로고
    • Simultaneous voltammetry determination of dihydroxybenzene isomers by poly-bromophenol blue/carbon nanotubes composite modified electrode
    • P.H. Yang, W.Z. Wei, C.Y. Tao, and J.X. Zeng Simultaneous voltammetry determination of dihydroxybenzene isomers by poly-bromophenol blue/carbon nanotubes composite modified electrode Bull. Environ. Contam. Toxicol. 79 2007 5 10
    • (2007) Bull. Environ. Contam. Toxicol. , vol.79 , pp. 5-10
    • Yang, P.H.1    Wei, W.Z.2    Tao, C.Y.3    Zeng, J.X.4
  • 16
    • 35348949036 scopus 로고    scopus 로고
    • Simultaneous determination of dihydroxybenzene isomers at single-wall carbon nanotube electrode
    • Z.H. Wang, S.J. Li, and Q.Z. Lv Simultaneous determination of dihydroxybenzene isomers at single-wall carbon nanotube electrode Sens. Actuators, B 127 2007 420 425
    • (2007) Sens. Actuators, B , vol.127 , pp. 420-425
    • Wang, Z.H.1    Li, S.J.2    Lv, Q.Z.3
  • 17
    • 58249128335 scopus 로고    scopus 로고
    • Application of multielectrode array modified with carbon nanotubes to simultaneous amperometric determination of dihydroxybenzene isomers
    • D.D. Zhang, Y.G. Peng, H.L. Qi, Q. Gao, and C.X. Zhang Application of multielectrode array modified with carbon nanotubes to simultaneous amperometric determination of dihydroxybenzene isomers Sens. Actuators, B 136 2009 113 121
    • (2009) Sens. Actuators, B , vol.136 , pp. 113-121
    • Zhang, D.D.1    Peng, Y.G.2    Qi, H.L.3    Gao, Q.4    Zhang, C.X.5
  • 18
    • 79955527015 scopus 로고    scopus 로고
    • 3 micro-particles modified by multi-walled carbon nanotubes enhance the ethanol gas sensing property
    • 3 micro-particles modified by multi-walled carbon nanotubes enhance the ethanol gas sensing property J. Nanosci. Nanotechnol. 10 2010 7045 7049
    • (2010) J. Nanosci. Nanotechnol. , vol.10 , pp. 7045-7049
    • Jia, X.1    Fan, H.2
  • 19
    • 33745663406 scopus 로고    scopus 로고
    • Carbon nanotubes contain metal impurities which are responsible for the "electrocatalysis" seen at some nanotube-modified electrodes
    • DOI 10.1002/anie.200600033
    • C.E. Banks, A. Crossley, C. Salter, S.J. Wilkins, and R.G. Compton Carbon nanotubes contain metal impurities which are responsible for the "electrocatalysis" seen at some nanotube-modified electrodes Angew. Chem. Int. Ed. 45 2006 2533 2537 (Pubitemid 44105751)
    • (2006) Angewandte Chemie - International Edition , vol.45 , Issue.16 , pp. 2533-2537
    • Banks, C.E.1    Crossley, A.2    Salter, C.3    Wilkins, S.J.4    Compton, R.G.5
  • 20
    • 43749100910 scopus 로고    scopus 로고
    • Copper oxide nanoparticle impurities are responsible for the electroanalytical detection of glucose seen using multiwalled carbon nanotubes
    • DOI 10.1016/j.snb.2008.01.049, PII S0925400508000865
    • C. Batchelor-McAuley, G.G. Wildgoose, R.G. Compton, L.D. Shao, and M.L.H. Green Copper oxide nanoparticle impurities are responsible for the electroanalytical detection of glucose seen using multiwalled carbon nanotubes Sens. Actuators, B 132 2008 356 360 (Pubitemid 351694439)
    • (2008) Sensors and Actuators, B: Chemical , vol.132 , Issue.1 , pp. 356-360
    • Batchelor-McAuley, C.1    Wildgoose, G.G.2    Compton, R.G.3    Shao, L.4    Green, M.L.H.5
  • 25
    • 78649921882 scopus 로고    scopus 로고
    • Single-walled carbon nanohorns and their applications
    • S.Y. Zhu, and G.B. Xu Single-walled carbon nanohorns and their applications Nanoscale 2 2010 2538 2549
    • (2010) Nanoscale , vol.2 , pp. 2538-2549
    • Zhu, S.Y.1    Xu, G.B.2
  • 26
    • 25144443639 scopus 로고    scopus 로고
    • Electrochemical oxidation of hydroquinone, resorcinol, and catechol on boron-doped diamond anodes
    • DOI 10.1021/es0500660
    • B. Nasr, G. Abdellatif, P. Canizares, C. Saez, J. Lobato, and M.A. Rodrigo Electrochemical oxidation of hydroquinone, resorcinol, and catechol on boron-doped diamond anodes Environ. Sci. Technol. 39 2005 7234 7239 (Pubitemid 41339090)
    • (2005) Environmental Science and Technology , vol.39 , Issue.18 , pp. 7234-7239
    • Nasr, B.1    Abdellatif, G.2    Canizares, P.3    Saez, C.4    Lobato, J.5    Rodrigo, M.A.6
  • 27
    • 67649994025 scopus 로고    scopus 로고
    • Simultaneous determination of hydroquinone and catechol using poly(p-aminobenzonic acid) modified glassy carbon electrode
    • P. Yang, Q.Y. Zhu, Y.H. Chen, and F.G. Wang Simultaneous determination of hydroquinone and catechol using poly(p-aminobenzonic acid) modified glassy carbon electrode J. Appl. Polym. Sci. 113 2009 2281 2286
    • (2009) J. Appl. Polym. Sci. , vol.113 , pp. 2281-2286
    • Yang, P.1    Zhu, Q.Y.2    Chen, Y.H.3    Wang, F.G.4
  • 28
    • 0002824580 scopus 로고    scopus 로고
    • Innovations in the study of the adsorbed reactants by chronocoulometry
    • F.C. Anson Innovations in the study of the adsorbed reactants by chronocoulometry Anal. Chem. 38 1996 54 57
    • (1996) Anal. Chem. , vol.38 , pp. 54-57
    • Anson, F.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.