메뉴 건너뛰기




Volumn , Issue , 2013, Pages 618-622

Wearable textile sensor sock for gait analysis

Author keywords

gait; plantar pressure; textile sensor sock

Indexed keywords

CONDUCTIVE THREADS; DAILY LIFE ACTIVITIES; FOOT PLANTAR PRESSURES; FUTURE APPLICATIONS; GAIT; PLANTAR PRESSURES; TEST-RETEST RELIABILITY; TEXTILE SENSORS;

EID: 84897825426     PISSN: 21568065     EISSN: 21568073     Source Type: Conference Proceeding    
DOI: 10.1109/ICSensT.2013.6727727     Document Type: Conference Paper
Times cited : (24)

References (12)
  • 1
    • 77953160299 scopus 로고    scopus 로고
    • In-shoe plantar pressure measurement and analysis system based on fabric pressure sensing array
    • L. Shu, T. Hua, Y. Wang, L.Q. Qiao, D.D. Feng, X. Tao, "In-shoe plantar pressure measurement and analysis system based on fabric pressure sensing array," IEEE Trans Inf Technol Biomed, vol. 14, pp.767-75, 2010.
    • (2010) IEEE Trans Inf Technol Biomed , vol.14 , pp. 767-775
    • Shu, L.1    Hua, T.2    Wang, Y.3    Qiao, L.Q.4    Feng, D.D.5    Tao, X.6
  • 2
    • 34047139472 scopus 로고    scopus 로고
    • Plantar pressure parameters for dynamic gait stability analysis
    • E.D. Lemaire, A. Biswas, J. Kofman, "Plantar pressure parameters for dynamic gait stability analysis," Conf Proc IEEE Eng Med Biol Soc, vol. 1, pp. 4465-4468, 2006.
    • (2006) Conf Proc IEEE Eng Med Biol Soc , vol.1 , pp. 4465-4468
    • Lemaire, E.D.1    Biswas, A.2    Kofman, J.3
  • 3
    • 0031127592 scopus 로고    scopus 로고
    • A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data
    • Z.O. Abu-Faraj, G.F. Harris, J.H. Abler, J.J Wertsch, "A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data," J Rehabil Res Dev, vol. 34, pp. 187-194, 1997.
    • (1997) J Rehabil Res Dev , vol.34 , pp. 187-194
    • Abu-Faraj, Z.O.1    Harris, G.F.2    Abler, J.H.3    Wertsch, J.J.4
  • 4
    • 0027006831 scopus 로고
    • A portable insole plantar pressure measurement system
    • J.J. Wertsch, J.G. Webster, W.J. Tompkins, "A portable insole plantar pressure measurement system," J Rehabil Res Dev, vol. 29, pp.13-8, 1992.
    • (1992) J Rehabil Res Dev , vol.29 , pp. 13-18
    • Wertsch, J.J.1    Webster, J.G.2    Tompkins, W.J.3
  • 8
    • 0034866316 scopus 로고    scopus 로고
    • Plantar pressure distribution during barefoot standing, walking and landing in preschool boys
    • E. Kellis, "Plantar pressure distribution during barefoot standing, walking and landing in preschool boys," Gait Posture, vol. 14, no. 2, pp. 92-97, 2001.
    • (2001) Gait Posture , vol.14 , Issue.2 , pp. 92-97
    • Kellis, E.1
  • 9
    • 23044446688 scopus 로고    scopus 로고
    • Foot pressure distribution during walking in young and old adults
    • M.J. Hessert, M. Vyas, J. Leach, K. Hu, L. , A. Lipsitz, and V. Novak, "Foot pressure distribution during walking in young and old adults," BMC Geriatr., vol. 5, pp. 8, 2005.
    • (2005) BMC Geriatr. , vol.5 , pp. 8
    • Hessert, M.J.1    Vyas, M.2    Leach, J.3    Hu, K.4    Lipsitz, A.5    Novak, V.6
  • 10
    • 34249934403 scopus 로고    scopus 로고
    • Agreement between footswitch and ground reaction force techniques for identifying gait events: Intersession repeatability and the effect of walking speed
    • P.M. Mills, R.S. Barrett, S. Morrison, "Agreement between footswitch and ground reaction force techniques for identifying gait events: intersession repeatability and the effect of walking speed," Gait Posture., vol 26, pp. 323-326, 2007.
    • (2007) Gait Posture. , vol.26 , pp. 323-326
    • Mills, P.M.1    Barrett, R.S.2    Morrison, S.3
  • 11
    • 0029256487 scopus 로고
    • Footswitch system for measurement of the temporal parameters of gait
    • J.M. Hausdorff, Z. Ladin, J.Y. Wei, "Footswitch system for measurement of the temporal parameters of gait," J Biomech. Vol 28, pp. 347-351, 1995.
    • (1995) J Biomech. , vol.28 , pp. 347-351
    • Hausdorff, J.M.1    Ladin, Z.2    Wei, J.Y.3
  • 12
    • 34047139472 scopus 로고    scopus 로고
    • Plantar pressure parameters for dynamic gait stability analysis
    • E.D. Lemaire, A. Biswas, J. Kofman, "Plantar Pressure Parameters for Dynamic Gait Stability Analysis," Conf Proc IEEE Eng Med Biol Soc., vol 1, pp. 4465-8, 2006.
    • (2006) Conf Proc IEEE Eng Med Biol Soc. , vol.1 , pp. 4465-4468
    • Lemaire, E.D.1    Biswas, A.2    Kofman, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.