메뉴 건너뛰기




Volumn 122, Issue , 2014, Pages 316-321

Electrochemical control of the standard potential of solid-contact ion-selective electrodes having a conducting polymer as ion-to-electron transducer

Author keywords

Chronoamperometry; Chronopotentiometry; Conducting polymer; Solid contact ion selective electrode; Standard potential

Indexed keywords

CHRONOPOTENTIOMETRY; ELECTROCHEMICAL CONTROL; ELECTROLYTE SOLUTIONS; OPEN-CIRCUIT POTENTIAL; POLY(3 ,4-ETHYLENEDIOXYTHIOPHENE); POLY(SODIUM 4-STYRENESULFONATE); PVC-BASED MEMBRANES; STANDARD POTENTIAL;

EID: 84897727993     PISSN: 00134686     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.electacta.2013.10.134     Document Type: Article
Times cited : (77)

References (25)
  • 1
    • 85004400305 scopus 로고
    • Calibration-free measurement of sodium and potassium in undiluted human serum with an electrically symmetric measuring system
    • G. Rumpf, U. Spichiger-Keller, H. Bühler, and W. Simon Calibration-free measurement of sodium and potassium in undiluted human serum with an electrically symmetric measuring system Anal. Sci. 8 1992 553
    • (1992) Anal. Sci. , vol.8 , pp. 553
    • Rumpf, G.1    Spichiger-Keller, U.2    Bühler, H.3    Simon, W.4
  • 3
    • 84861865706 scopus 로고    scopus 로고
    • All-solid-state ion selective and all-solid-state reference electrodes
    • A. Michalska All-solid-state ion selective and all-solid-state reference electrodes Electroanalysis 24 2012 1253
    • (2012) Electroanalysis , vol.24 , pp. 1253
    • Michalska, A.1
  • 4
    • 54249148419 scopus 로고    scopus 로고
    • Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes
    • E. Lindner, and R.E. Gyurcsányi Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes J. Solid State Electrochem. 13 2009 51
    • (2009) J. Solid State Electrochem. , vol.13 , pp. 51
    • Lindner, E.1    Gyurcsányi, R.E.2
  • 5
    • 84859402737 scopus 로고    scopus 로고
    • Effective solid contact for ion-selective electrodes: Tetrakis(4-chlorophenyl)borate (TB-) anions doped nanocluster films
    • M. Zhou, S. Gan, B. Cai, F. Li, W. Ma, D. Han, and L. Niu Effective solid contact for ion-selective electrodes: tetrakis(4-chlorophenyl)borate (TB-) anions doped nanocluster films Anal. Chem. 84 2012 3480
    • (2012) Anal. Chem. , vol.84 , pp. 3480
    • Zhou, M.1    Gan, S.2    Cai, B.3    Li, F.4    Ma, W.5    Han, D.6    Niu, L.7
  • 6
    • 77955421333 scopus 로고    scopus 로고
    • Experimental study on stability of different solid-contact arrangements of ion-selective electrodes
    • A. Michalska, M. Wojciechowski, E. Bulska, and K. Maksymiuk Experimental study on stability of different solid-contact arrangements of ion-selective electrodes Talanta 82 2010 151
    • (2010) Talanta , vol.82 , pp. 151
    • Michalska, A.1    Wojciechowski, M.2    Bulska, E.3    Maksymiuk, K.4
  • 7
    • 29544444766 scopus 로고    scopus 로고
    • Optimizing the analytical performance and construction of ion-selective electrodes
    • A. Michalska Optimizing the analytical performance and construction of ion-selective electrodes Anal. Bioanal. Chem. 384 2006 391
    • (2006) Anal. Bioanal. Chem. , vol.384 , pp. 391
    • Michalska, A.1
  • 8
    • 0033661549 scopus 로고    scopus 로고
    • Potential drifts of solid-contacted ion-selective electrodes due to zero-current ion fluxes through the sensor membrane
    • M. Fibbioli, W.E. Morf, M. Badertscher, N.F. de Rooij, and E. Pretsch Potential drifts of solid-contacted ion-selective electrodes due to zero-current ion fluxes through the sensor membrane Electroanalysis 12 2000 1286
    • (2000) Electroanalysis , vol.12 , pp. 1286
    • Fibbioli, M.1    Morf, W.E.2    Badertscher, M.3    De Rooij, N.F.4    Pretsch, E.5
  • 9
    • 79959193691 scopus 로고    scopus 로고
    • Hyphenated FT-IR-attenuated total reflection and electrochemical impedance spectroscopy technique to study the water uptake and potential stability of polymeric solid contact ion-selective electrodes
    • T. Lindfors, L. Höfler, G. Jágerszki, and R.E. Gyurcsányi Hyphenated FT-IR-attenuated total reflection and electrochemical impedance spectroscopy technique to study the water uptake and potential stability of polymeric solid contact ion-selective electrodes Anal. Chem. 83 2011 4902
    • (2011) Anal. Chem. , vol.83 , pp. 4902
    • Lindfors, T.1    Höfler, L.2    Jágerszki, G.3    Gyurcsányi, R.E.4
  • 10
    • 80054717698 scopus 로고    scopus 로고
    • Important aspects influencing stability of the electrochemical potential of conductive polymer-based electrodes
    • T.V. Shishkanova, G. Broncova, M. Krondak, D. Sykora, and V. Kral Important aspects influencing stability of the electrochemical potential of conductive polymer-based electrodes J. Mater. Sci. 46 2011 7594
    • (2011) J. Mater. Sci. , vol.46 , pp. 7594
    • Shishkanova, T.V.1    Broncova, G.2    Krondak, M.3    Sykora, D.4    Kral, V.5
  • 12
    • 0033230919 scopus 로고    scopus 로고
    • Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers
    • J. Bobacka Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers Anal. Chem. 71 1999 4932
    • (1999) Anal. Chem. , vol.71 , pp. 4932
    • Bobacka, J.1
  • 13
    • 34347235836 scopus 로고    scopus 로고
    • Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact
    • C-Z. Lai, M.A. Fierke, A. Stein, and P. Bühlmann Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact Anal. Chem. 79 2007 4621
    • (2007) Anal. Chem. , vol.79 , pp. 4621
    • Lai, C.-Z.1    Fierke, M.A.2    Stein, A.3    Bühlmann, P.4
  • 14
    • 39449110385 scopus 로고    scopus 로고
    • Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers
    • G.A. Crespo, S. Macho, and F.X. Rius Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers Anal. Chem. 80 2008 1316
    • (2008) Anal. Chem. , vol.80 , pp. 1316
    • Crespo, G.A.1    Macho, S.2    Rius, F.X.3
  • 15
    • 81355161376 scopus 로고    scopus 로고
    • Impedance study of the ion-to-electron transduction process for carbon cloth as solid-contact material in potentiometric ion sensors
    • U. Mattinen, S. Rabiej, A. Lewenstam, and J. Bobacka Impedance study of the ion-to-electron transduction process for carbon cloth as solid-contact material in potentiometric ion sensors Electrochim. Acta 56 2011 10683
    • (2011) Electrochim. Acta , vol.56 , pp. 10683
    • Mattinen, U.1    Rabiej, S.2    Lewenstam, A.3    Bobacka, J.4
  • 16
    • 0001270359 scopus 로고
    • All-solid-state sodium-selective electrode based on a calixarene ionophore in a poly(vinyl chloride) membrane with a polypyrrole solid contact
    • A. Cadogan, Z. Gao, A. Lewenstam, A. Ivaska, and D. Diamond All-solid-state sodium-selective electrode based on a calixarene ionophore in a poly(vinyl chloride) membrane with a polypyrrole solid contact Anal. Chem. 64 1992 2496
    • (1992) Anal. Chem. , vol.64 , pp. 2496
    • Cadogan, A.1    Gao, Z.2    Lewenstam, A.3    Ivaska, A.4    Diamond, D.5
  • 17
    • 84861339305 scopus 로고    scopus 로고
    • Disposable solid-contact ion-selective electrodes for environmental monitoring of lead with ppb limit-of-detection
    • S. Anastasova, A. Radu, G. Matzeu, C. Zuliani, U. Mattinen, J. Bobacka, and D. Diamond Disposable solid-contact ion-selective electrodes for environmental monitoring of lead with ppb limit-of-detection Electrochim. Acta 73 2012 93
    • (2012) Electrochim. Acta , vol.73 , pp. 93
    • Anastasova, S.1    Radu, A.2    Matzeu, G.3    Zuliani, C.4    Mattinen, U.5    Bobacka, J.6    Diamond, D.7
  • 18
    • 13544261406 scopus 로고    scopus 로고
    • The influence of spontaneous charging/discharging of conducting polymer ion-to-electron transducer on potentiometric response of all-solid-state calcium-selective electrodes
    • A. Michalska, and K. Maksymiuk The influence of spontaneous charging/discharging of conducting polymer ion-to-electron transducer on potentiometric response of all-solid-state calcium-selective electrodes J. Electroanal. Chem. 576 2005 339
    • (2005) J. Electroanal. Chem. , vol.576 , pp. 339
    • Michalska, A.1    Maksymiuk, K.2
  • 19
    • 0034993930 scopus 로고    scopus 로고
    • Studies on spontaneous charging/discharging processes of polypyrrole in aqueous electrolyte solutions
    • J. Dumańska, and K. Maksymiuk Studies on spontaneous charging/discharging processes of polypyrrole in aqueous electrolyte solutions Electroanalysis 13 2001 567
    • (2001) Electroanalysis , vol.13 , pp. 567
    • Dumańska, J.1    Maksymiuk, K.2
  • 20
    • 0141924478 scopus 로고    scopus 로고
    • Lowering the detection limit of ion-selective plastic membrane electrodes with conducting polymer potentiometric sensors
    • A. Michalska, J. Dumańska, and K. Maksymiuk Lowering the detection limit of ion-selective plastic membrane electrodes with conducting polymer potentiometric sensors Anal. Chem. 75 2003 4964
    • (2003) Anal. Chem. , vol.75 , pp. 4964
    • Michalska, A.1    Dumańska, J.2    Maksymiuk, K.3
  • 21
    • 0041471000 scopus 로고
    • Mechanism of ionic and redox sensitivity of p-type conducting polymers, Part 1. Theory
    • A. Lewenstam, J. Bobacka, and A. Ivaska Mechanism of ionic and redox sensitivity of p-type conducting polymers, Part 1. Theory J. Electroanal. Chem. 368 1994 23
    • (1994) J. Electroanal. Chem. , vol.368 , pp. 23
    • Lewenstam, A.1    Bobacka, J.2    Ivaska, A.3
  • 22
    • 0002708985 scopus 로고
    • Mechanism of ionic and redox sensitivity of p-type conducting polymers, Part 2. Experimental study of polypyrrole
    • J. Bobacka, Z. Gao, A. Ivaska, and A. Lewenstam Mechanism of ionic and redox sensitivity of p-type conducting polymers, Part 2. Experimental study of polypyrrole J. Electroanal. Chem. 368 1994 33
    • (1994) J. Electroanal. Chem. , vol.368 , pp. 33
    • Bobacka, J.1    Gao, Z.2    Ivaska, A.3    Lewenstam, A.4
  • 23
    • 20444489282 scopus 로고    scopus 로고
    • Improvement of analytical characteristic of calcium selective electrode with conducting polymer contact. The role of conducting polymer spontaneous charge transfer processes and their galvanostatic compensation
    • A. Michalska Improvement of analytical characteristic of calcium selective electrode with conducting polymer contact. The role of conducting polymer spontaneous charge transfer processes and their galvanostatic compensation Electroanalysis 17 2005 400
    • (2005) Electroanalysis , vol.17 , pp. 400
    • Michalska, A.1
  • 24
    • 0035838837 scopus 로고    scopus 로고
    • Equilibrium potential of potentiometric ion sensors under steady-state current by using current-reversal chronopotentiometry
    • J. Bobacka, A. Lewenstam, and A. Ivaska Equilibrium potential of potentiometric ion sensors under steady-state current by using current-reversal chronopotentiometry J. Electroanal. Chem. 509 2001 27
    • (2001) J. Electroanal. Chem. , vol.509 , pp. 27
    • Bobacka, J.1    Lewenstam, A.2    Ivaska, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.