메뉴 건너뛰기




Volumn 7, Issue 3, 2014, Pages 289-303

Numerical multi-physical approach for the assessment of coupled heat and moisture transfer combined with people movements in historical buildings

Author keywords

air quality; CFD FEM; cultural heritage; historical buildings; indoor microclimatic conditions; transient simulation

Indexed keywords


EID: 84897706590     PISSN: 19963599     EISSN: 19968744     Source Type: Journal    
DOI: 10.1007/s12273-013-0146-3     Document Type: Article
Times cited : (13)

References (31)
  • 1
    • 55549131892 scopus 로고    scopus 로고
    • Moisture performance of building materials: From material characterization to building simulation using the Moisture Buffer Value concept
    • Abadie MO, Mendonça KC (2009). Moisture performance of building materials: From material characterization to building simulation using the Moisture Buffer Value concept. Building and Environment, 44: 388-401.
    • (2009) Building and Environment , vol.44 , pp. 388-401
    • Abadie, M.O.1    Mendonça, K.C.2
  • 2
    • 79951954217 scopus 로고    scopus 로고
    • Contribution to analytical and numerical study of combined heat and moisture transfer in porous building materials
    • Abahari K, Belarbi R, Trabelsi A (2011). Contribution to analytical and numerical study of combined heat and moisture transfer in porous building materials. Building and Environment, 46: 1354-1360.
    • (2011) Building and Environment , vol.46 , pp. 1354-1360
    • Abahari, K.1    Belarbi, R.2    Trabelsi, A.3
  • 5
    • 84940763212 scopus 로고    scopus 로고
    • Museums, libraries and archives
    • ASHRAE
    • ASHRAE (2003). Museums, libraries and archives. Chapter 21 in ASHRAE Handbook.
    • (2003) Chapter 21 in ASHRAE Handbook
  • 9
    • 84864762018 scopus 로고    scopus 로고
    • Assessing the effects of sliding doors on an operating theatre climate
    • Balocco C, Petrone G, Cammarata G (2012). Assessing the effects of sliding doors on an operating theatre climate. Building Simulation, 5: 73-83.
    • (2012) Building Simulation , vol.5 , pp. 73-83
    • Balocco, C.1    Petrone, G.2    Cammarata, G.3
  • 12
    • 0000763833 scopus 로고
    • A modified Newton method for the solution of ill-conditioned systems of nonlinear equations with application to multiple shooting
    • Deuflhard P (1974). A modified Newton method for the solution of ill-conditioned systems of nonlinear equations with application to multiple shooting. Numerical Mathematics, 22: 289-315.
    • (1974) Numerical Mathematics , vol.22 , pp. 289-315
    • Deuflhard, P.1
  • 14
    • 0036135315 scopus 로고    scopus 로고
    • Effect of moisture transfer across building components on room temperature
    • Gaur RC, Bansal NK (2002). Effect of moisture transfer across building components on room temperature. Building and Environment, 37: 11-17.
    • (2002) Building and Environment , vol.37 , pp. 11-17
    • Gaur, R.C.1    Bansal, N.K.2
  • 18
    • 0021141934 scopus 로고
    • Transient analysis of the thermal and moisture physical behaviour of building construction
    • Kohonen R (1984). Transient analysis of the thermal and moisture physical behaviour of building construction. Building and Environment, 19: 1-11.
    • (1984) Building and Environment , vol.19 , pp. 1-11
    • Kohonen, R.1
  • 19
    • 84857048024 scopus 로고    scopus 로고
    • An analytical solution of a moisture transfer problem for coupled room and building component
    • Korjenic A, Bednar T (2012). An analytical solution of a moisture transfer problem for coupled room and building component. Energy and Buildings, 47: 254-259.
    • (2012) Energy and Buildings , vol.47 , pp. 254-259
    • Korjenic, A.1    Bednar, T.2
  • 20
    • 84864912438 scopus 로고    scopus 로고
    • A quasi-steady state implementation of air convection in a transient heat and moisture building component model
    • Langmans J, Nicolai A, Klein R, Roels S (2012). A quasi-steady state implementation of air convection in a transient heat and moisture building component model. Building and Environment, 58: 208-218.
    • (2012) Building and Environment , vol.58 , pp. 208-218
    • Langmans, J.1    Nicolai, A.2    Klein, R.3    Roels, S.4
  • 21
    • 0036837016 scopus 로고    scopus 로고
    • Modelling of heat and moisture transfer in buildings. Model program
    • Lu X (2002). Modelling of heat and moisture transfer in buildings. Model program. Energy and Buildings, 34: 1033-1043.
    • (2002) Energy and Buildings , vol.34 , pp. 1033-1043
    • Lu, X.1
  • 26
    • 78049473464 scopus 로고    scopus 로고
    • Numerical analysis of air flow, heat transfer, moisture transport and thermal comfort in a room heated by two-panel radiators
    • Selvilgen G, Kilic K (2011). Numerical analysis of air flow, heat transfer, moisture transport and thermal comfort in a room heated by two-panel radiators. Energy and Buildings, 43: 137-146.
    • (2011) Energy and Buildings , vol.43 , pp. 137-146
    • Selvilgen, G.1    Kilic, K.2
  • 27
    • 77953291155 scopus 로고    scopus 로고
    • Transient model for coupled heat, air and moisture transfer through multilayered porous media
    • Tariku F, Kumaran K, Fazio P (2010). Transient model for coupled heat, air and moisture transfer through multilayered porous media. International Journal of Heat and Mass Transfer, 53: 3035-3044.
    • (2010) International Journal of Heat and Mass Transfer , vol.53 , pp. 3035-3044
    • Tariku, F.1    Kumaran, K.2    Fazio, P.3
  • 31
    • 60249083740 scopus 로고    scopus 로고
    • Model-based moisture sorption stabilization in historical buildings
    • Zitek P, Vyhlidal T (2009). Model-based moisture sorption stabilization in historical buildings. Building and Environment, 44: 1181-1187.
    • (2009) Building and Environment , vol.44 , pp. 1181-1187
    • Zitek, P.1    Vyhlidal, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.