메뉴 건너뛰기




Volumn 41, Issue 1, 2014, Pages 45-51

Improving detection of ischemic lesions at 3 Tesla with optimized diffusion-weighted magnetic resonance imaging

Author keywords

Diffusion; DWI; MRI; Stroke

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; BRAIN ISCHEMIA; BRAIN STEM INJURY; CLINICAL ARTICLE; DIAGNOSTIC TEST ACCURACY STUDY; DIFFUSION WEIGHTED IMAGING; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; INTERMETHOD COMPARISON; MALE; OBSERVER VARIATION; POSTERIOR FOSSA; PREDICTIVE VALUE; PROCESS OPTIMIZATION; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; RECEIVER OPERATING CHARACTERISTIC; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SIGNAL DETECTION; TRANSIENT ISCHEMIC ATTACK; VERY ELDERLY; BRAIN; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; IMAGE ENHANCEMENT; MIDDLE AGED; PATHOLOGY; PROCEDURES;

EID: 84897654208     PISSN: 01509861     EISSN: 17730406     Source Type: Journal    
DOI: 10.1016/j.neurad.2013.04.003     Document Type: Article
Times cited : (11)

References (22)
  • 1
    • 33748523428 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging versus computed tomography in the diagnosis of acute ischemic stroke
    • Davis D.P., Robertson T., Imbesi S.G. Diffusion-weighted magnetic resonance imaging versus computed tomography in the diagnosis of acute ischemic stroke. J Emerg Med 2006, 31:269-277.
    • (2006) J Emerg Med , vol.31 , pp. 269-277
    • Davis, D.P.1    Robertson, T.2    Imbesi, S.G.3
  • 2
    • 77954749308 scopus 로고    scopus 로고
    • Evidence-based guideline: the role of diffusion and perfusion MRI for the diagnosis of acute ischemic stroke: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology
    • Schellinger P.D., Bryan R.N., Caplan L.R., et al. Evidence-based guideline: the role of diffusion and perfusion MRI for the diagnosis of acute ischemic stroke: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Neurology 2010, 75:177-185.
    • (2010) Neurology , vol.75 , pp. 177-185
    • Schellinger, P.D.1    Bryan, R.N.2    Caplan, L.R.3
  • 3
    • 0036794913 scopus 로고    scopus 로고
    • Quantitative diffusion-weighted MR imaging in transient ischemic attacks
    • Kamal A.K., Segal A.Z., Ulug A.M. Quantitative diffusion-weighted MR imaging in transient ischemic attacks. AJNR Am J Neuroradiol 2002, 23:1533-1538.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1533-1538
    • Kamal, A.K.1    Segal, A.Z.2    Ulug, A.M.3
  • 4
    • 16444378858 scopus 로고    scopus 로고
    • [Quantitative relationships between ADC and perfusion changes in acute ischemic stroke using combined diffusion-weighted imaging and perfusion MR (DWI/PMR)]
    • Hamon M., Marie R.M., Clochon P., et al. [Quantitative relationships between ADC and perfusion changes in acute ischemic stroke using combined diffusion-weighted imaging and perfusion MR (DWI/PMR)]. J Neuroradiol 2005, 32:118-124.
    • (2005) J Neuroradiol , vol.32 , pp. 118-124
    • Hamon, M.1    Marie, R.M.2    Clochon, P.3
  • 5
    • 0031658306 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging in acute stroke
    • van Everdingen K.J., van der Grond J., Kappelle L.J., et al. Diffusion-weighted magnetic resonance imaging in acute stroke. Stroke 1998, 29:1783-1790.
    • (1998) Stroke , vol.29 , pp. 1783-1790
    • van Everdingen, K.J.1    van der Grond, J.2    Kappelle, L.J.3
  • 6
    • 0036656564 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of cerebral infarctions: are higher B values better?
    • Burdette J.H., Elster A.D. Diffusion-weighted imaging of cerebral infarctions: are higher B values better?. J Comput Assist Tomogr 2002, 26:622-627.
    • (2002) J Comput Assist Tomogr , vol.26 , pp. 622-627
    • Burdette, J.H.1    Elster, A.D.2
  • 7
    • 0036238190 scopus 로고    scopus 로고
    • Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischemic stroke
    • Pereira R.S., Harris A.D., Sevick R.J., et al. Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischemic stroke. J Magn Reson Imaging 2002, 15:591-596.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 591-596
    • Pereira, R.S.1    Harris, A.D.2    Sevick, R.J.3
  • 8
    • 30144443409 scopus 로고    scopus 로고
    • High-b-value diffusion-weighted MR imaging of hyperacute ischemic stroke at 1.5T
    • Kim H.J., Choi C.G., Lee D.H., et al. High-b-value diffusion-weighted MR imaging of hyperacute ischemic stroke at 1.5T. AJNR Am J Neuroradiol 2005, 26:208-215.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 208-215
    • Kim, H.J.1    Choi, C.G.2    Lee, D.H.3
  • 9
    • 34247868130 scopus 로고    scopus 로고
    • Usefulness of high-b-value diffusion-weighted imaging in acute cerebral infarction
    • Toyoda K., Kitai S., Ida M., et al. Usefulness of high-b-value diffusion-weighted imaging in acute cerebral infarction. Eur Radiol 2007, 17:1212-1220.
    • (2007) Eur Radiol , vol.17 , pp. 1212-1220
    • Toyoda, K.1    Kitai, S.2    Ida, M.3
  • 10
    • 79951598263 scopus 로고    scopus 로고
    • The utility of high b-value DWI in evaluation of ischemic stroke at 3T
    • Cihangiroglu M., Citci B., Kilickesmez O., et al. The utility of high b-value DWI in evaluation of ischemic stroke at 3T. Eur J Radiol 2011, 78:75-81.
    • (2011) Eur J Radiol , vol.78 , pp. 75-81
    • Cihangiroglu, M.1    Citci, B.2    Kilickesmez, O.3
  • 11
    • 33644923780 scopus 로고    scopus 로고
    • Accident vasculaire cérébral ischémique et tenseur de diffusion
    • Rodrigo S., Oppenheim C., Touze E., et al. Accident vasculaire cérébral ischémique et tenseur de diffusion. J Neuroradiol 2006, 33:51-56.
    • (2006) J Neuroradiol , vol.33 , pp. 51-56
    • Rodrigo, S.1    Oppenheim, C.2    Touze, E.3
  • 12
    • 39649103898 scopus 로고    scopus 로고
    • Comparison of optimized and standard diffusion-weighted imaging at 1.5T for the detection of acute lesions in patients with transient ischemic attack
    • Bertrand A., Oppenheim C., Lamy C., et al. Comparison of optimized and standard diffusion-weighted imaging at 1.5T for the detection of acute lesions in patients with transient ischemic attack. AJNR Am J Neuroradiol 2008, 29:363-365.
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 363-365
    • Bertrand, A.1    Oppenheim, C.2    Lamy, C.3
  • 13
    • 12344336382 scopus 로고    scopus 로고
    • Acute and subacute ischemic stroke at high-field-strength (3.0-T) diffusion-weighted MR imaging: intraindividual comparative study
    • Kuhl C.K., Textor J., Gieseke J., et al. Acute and subacute ischemic stroke at high-field-strength (3.0-T) diffusion-weighted MR imaging: intraindividual comparative study. Radiology 2005, 234:509-516.
    • (2005) Radiology , vol.234 , pp. 509-516
    • Kuhl, C.K.1    Textor, J.2    Gieseke, J.3
  • 14
    • 77953808745 scopus 로고    scopus 로고
    • Diffusion-weighted MRI in acute stroke within the first 6hours: 1.5 or 3.0Tesla?
    • Rosso C., Drier A., Lacroix D., et al. Diffusion-weighted MRI in acute stroke within the first 6hours: 1.5 or 3.0Tesla?. Neurology 2010, 74:1946-1953.
    • (2010) Neurology , vol.74 , pp. 1946-1953
    • Rosso, C.1    Drier, A.2    Lacroix, D.3
  • 15
    • 77953807824 scopus 로고    scopus 로고
    • Less could be more when it comes to diffusion imaging of acute stroke
    • Kosior R.K., Hill M.D., Frayne R. Less could be more when it comes to diffusion imaging of acute stroke. Neurology 2010, 74:1936-1937.
    • (2010) Neurology , vol.74 , pp. 1936-1937
    • Kosior, R.K.1    Hill, M.D.2    Frayne, R.3
  • 16
    • 29444460978 scopus 로고    scopus 로고
    • Acute ischemic stroke: accuracy of diffusion-weighted MR imaging-effects of b value and cerebrospinal fluid suppression
    • Chen P.E., Simon J.E., Hill M.D., et al. Acute ischemic stroke: accuracy of diffusion-weighted MR imaging-effects of b value and cerebrospinal fluid suppression. Radiology 2006, 238:232-239.
    • (2006) Radiology , vol.238 , pp. 232-239
    • Chen, P.E.1    Simon, J.E.2    Hill, M.D.3
  • 17
    • 77956561560 scopus 로고    scopus 로고
    • Quality-evaluation scheme for cerebral time-resolved 3D contrast-enhanced MR angiography techniques
    • Raoult H., Ferre J.C., Morandi X., et al. Quality-evaluation scheme for cerebral time-resolved 3D contrast-enhanced MR angiography techniques. AJNR Am J Neuroradiol 2010, 31:1480-1487.
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 1480-1487
    • Raoult, H.1    Ferre, J.C.2    Morandi, X.3
  • 18
    • 62849092155 scopus 로고    scopus 로고
    • High b-value diffusion-weighted MR imaging of normal brain at 3T
    • Cihangiroglu M., Ulug A.M., Firat Z., et al. High b-value diffusion-weighted MR imaging of normal brain at 3T. Eur J Radiol 2009, 69:454-458.
    • (2009) Eur J Radiol , vol.69 , pp. 454-458
    • Cihangiroglu, M.1    Ulug, A.M.2    Firat, Z.3
  • 19
    • 84867863893 scopus 로고    scopus 로고
    • 3-T high-b-value diffusion-weighted MR imaging of hyperacute ischemic stroke in the vertebrobasilar territory
    • Lettau M., Laible M. 3-T high-b-value diffusion-weighted MR imaging of hyperacute ischemic stroke in the vertebrobasilar territory. J Neuroradiol 2012, 39:243-253.
    • (2012) J Neuroradiol , vol.39 , pp. 243-253
    • Lettau, M.1    Laible, M.2
  • 20
    • 33645756562 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging in transient ischaemic attacks
    • Lamy C., Oppenheim C., Calvet D., et al. Diffusion-weighted MR imaging in transient ischaemic attacks. Eur Radiol 2006, 16:1090-1095.
    • (2006) Eur Radiol , vol.16 , pp. 1090-1095
    • Lamy, C.1    Oppenheim, C.2    Calvet, D.3
  • 21
    • 0035173399 scopus 로고    scopus 로고
    • Is there an apparent diffusion coefficient threshold in predicting tissue viability in hyperacute stroke?
    • Oppenheim C., Grandin C., Samson Y., et al. Is there an apparent diffusion coefficient threshold in predicting tissue viability in hyperacute stroke?. Stroke 2001, 32:2486-2491.
    • (2001) Stroke , vol.32 , pp. 2486-2491
    • Oppenheim, C.1    Grandin, C.2    Samson, Y.3
  • 22
    • 67449168637 scopus 로고    scopus 로고
    • Does diffusion-weighted imaging represent the ischemic core? An evidence-based systematic review
    • Kranz P.G., Eastwood J.D. Does diffusion-weighted imaging represent the ischemic core? An evidence-based systematic review. AJNR Am J Neuroradiol 2009, 30:1206-1212.
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 1206-1212
    • Kranz, P.G.1    Eastwood, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.