메뉴 건너뛰기




Volumn 14, Issue , 2014, Pages

The practice of venous blood collection among laboratory and non-laboratory professionals working in Ethiopian Government Hospitals: A comparative study

Author keywords

Ethiopia; Pre analytical error; Venous blood collection

Indexed keywords

ADULT; BLOOD SAMPLING; COMPARATIVE STUDY; CROSS-SECTIONAL STUDY; EPIDEMIOLOGY; ETHIOPIA; FEMALE; HOSPITAL LABORATORY; HOSPITAL PERSONNEL; HUMAN; MALE; PROCEDURES; PUBLIC HOSPITAL; STANDARDS; STATISTICS AND NUMERICAL DATA; YOUNG ADULT;

EID: 84897640361     PISSN: None     EISSN: 14726963     Source Type: Journal    
DOI: 10.1186/1472-6963-14-88     Document Type: Article
Times cited : (10)

References (29)
  • 3
    • 74549191326 scopus 로고    scopus 로고
    • Evaluation of errors in a clinical laboratory: A one-year experience
    • 20047530
    • Evaluation of errors in a clinical laboratory: a one-year experience. Goswami B, Singh B, Chawla R, Mallika V, Clin Chem Lab Med 2010 48 1 63 66 20047530
    • (2010) Clin Chem Lab Med , vol.48 , Issue.1 , pp. 63-66
    • Goswami, B.1    Singh, B.2    Chawla, R.3    Mallika, V.4
  • 4
    • 33744786784 scopus 로고    scopus 로고
    • Errors in clinical laboratories or errors in laboratory medicine?
    • 16729864
    • Errors in clinical laboratories or errors in laboratory medicine? Plebani M, Clin Chem Lab Med 2006 44 6 750 759 16729864
    • (2006) Clin Chem Lab Med , vol.44 , Issue.6 , pp. 750-759
    • Plebani, M.1
  • 5
    • 10044282992 scopus 로고    scopus 로고
    • Errors in pathology and laboratory medicine: Consequences and prevention
    • 10.1002/jso.20125 15562462
    • Errors in pathology and laboratory medicine: consequences and prevention. Hollensead SC, Lockwood WB, Elin RJ, J Surg Oncol 2004 88 161 181 10.1002/jso.20125 15562462
    • (2004) J Surg Oncol , vol.88 , pp. 161-181
    • Hollensead, S.C.1    Lockwood, W.B.2    Elin, R.J.3
  • 6
    • 74049146302 scopus 로고    scopus 로고
    • Preanalytical variables and laboratory performance
    • 10.1007/s12291-009-0021-2 23105818
    • Preanalytical variables and laboratory performance. Sharma P, Indian J Clin Biochem 2009 24 2 109 110 10.1007/s12291-009-0021-2 23105818
    • (2009) Indian J Clin Biochem , vol.24 , Issue.2 , pp. 109-110
    • Sharma, P.1
  • 7
    • 0030797124 scopus 로고    scopus 로고
    • Mistakes in a stat laboratory: Types and frequency
    • 9267312
    • Mistakes in a stat laboratory: types and frequency. Plebani M, Carraro P, Clin Chem 1997 43 1348 1351 9267312
    • (1997) Clin Chem , vol.43 , pp. 1348-1351
    • Plebani, M.1    Carraro, P.2
  • 8
    • 56549100878 scopus 로고    scopus 로고
    • Frequency and type of preanalytical errors in a laboratory medicine department in India
    • 19012534
    • Frequency and type of preanalytical errors in a laboratory medicine department in India. Rattan A, Lippi G, Clin Chem Lab Med 2008 46 11 1657 1659 19012534
    • (2008) Clin Chem Lab Med , vol.46 , Issue.11 , pp. 1657-1659
    • Rattan, A.1    Lippi, G.2
  • 9
    • 34347402441 scopus 로고    scopus 로고
    • Errors in a stat laboratory: Types and frequencies 10 years later
    • 10.1373/clinchem.2007.088344 17525103
    • Errors in a stat laboratory: types and frequencies 10 years later. Carraro P, Plebani M, Clin Chem 2007 53 7 1338 1342 10.1373/clinchem.2007.088344 17525103
    • (2007) Clin Chem , vol.53 , Issue.7 , pp. 1338-1342
    • Carraro, P.1    Plebani, M.2
  • 10
    • 33745875319 scopus 로고    scopus 로고
    • Phlebotomy issues and quality improvement in results of laboratory testing
    • 16812947
    • Phlebotomy issues and quality improvement in results of laboratory testing. Lippi G, Salvagno GL, Montagnana M, Franchini M, Guidi GC, Clin Lab 2006 52 217 230 16812947
    • (2006) Clin Lab , vol.52 , pp. 217-230
    • Lippi, G.1    Salvagno, G.L.2    Montagnana, M.3    Franchini, M.4    Guidi, G.C.5
  • 11
    • 28444436955 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute (CLSI) CLSI, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898 USA: CLSI document H3-A6 (ISBN 1-56238-650-6)
    • Clinical and Laboratory Standards Institute (CLSI), Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard CLSI, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898 USA: CLSI document H3-A6 (ISBN 1-56238-650-6) 2007
    • (2007) Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard
  • 12
    • 77955730068 scopus 로고    scopus 로고
    • Blood sample collection and patient identification demand improvement: A questionnaire study of preanalytical practices in hospital wards and laboratories
    • 10.1111/j.1471-6712.2009.00753.x 21050248
    • Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories. Wallin O, Söderberg J, Van Guelpen B, Stenlund H, Grankvist K, Brulin C, Scand J Caring Sci 2010 24 581 591 10.1111/j.1471-6712.2009.00753.x 21050248
    • (2010) Scand J Caring Sci , vol.24 , pp. 581-591
    • Wallin, O.1    Söderberg, J.2    Van Guelpen, B.3    Stenlund, H.4    Grankvist, K.5    Brulin, C.6
  • 13
    • 3042740322 scopus 로고    scopus 로고
    • Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 - Month monitoring
    • 11696253
    • Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6-month monitoring. Wiwanitkit V, BMC Clin Pathol 2001 1 5 5 11696253
    • (2001) BMC Clin Pathol , vol.1 , Issue.5 , pp. 5
    • Wiwanitkit, V.1
  • 14
    • 0027212252 scopus 로고
    • Wristband identification error reporting in 712 hospitals. A College of American Pathologists' Q-Probes study of quality issues in transfusion practice
    • 8503724
    • Wristband identification error reporting in 712 hospitals. A College of American Pathologists' Q-Probes study of quality issues in transfusion practice. Renner SW, Howanitz PJ, Bachner P, Arch Pathol Lab Med 1993 117 573 577 8503724
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 573-577
    • Renner, S.W.1    Howanitz, P.J.2    Bachner, P.3
  • 16
    • 0028864787 scopus 로고
    • Redistribution of body fluids during postural manipulations
    • 10.1111/j.1748-1716.1995.tb09960.x 8669288
    • Redistribution of body fluids during postural manipulations. Maw GJ, Mackenzie IL, Taylor NA, Acta Physiol Scand 1995 155 157 163 10.1111/j.1748-1716.1995.tb09960.x 8669288
    • (1995) Acta Physiol Scand , vol.155 , pp. 157-163
    • Maw, G.J.1    Mackenzie, I.L.2    Taylor, N.A.3
  • 18
    • 77951965160 scopus 로고    scopus 로고
    • Identification of the types of preanalytical errors in the clinical chemistry laboratory: 1-year study at G.B. Pant hospital
    • 10.1309/LM9JXZBMLSVJT9RK
    • Identification of the types of preanalytical errors in the clinical chemistry laboratory: 1-year study at G.B. Pant hospital. Chawla R, Goswami B, Tayal D, Mallika V, Lab Medicine 2010 41 2 89 92 10.1309/LM9JXZBMLSVJT9RK
    • (2010) Lab Medicine , vol.41 , Issue.2 , pp. 89-92
    • Chawla, R.1    Goswami, B.2    Tayal, D.3    Mallika, V.4
  • 19
    • 77953868631 scopus 로고    scopus 로고
    • The prevalence of preanalytical errors in a Croatian ISO 15189 accredited laboratory
    • 20441481
    • The prevalence of preanalytical errors in a Croatian ISO 15189 accredited laboratory. Simundic AM, Nikolac N, Vukasovic I, Vrkic N, Clin Chem Lab Med 2010 48 7 1009 1014 20441481
    • (2010) Clin Chem Lab Med , vol.48 , Issue.7 , pp. 1009-1014
    • Simundic, A.M.1    Nikolac, N.2    Vukasovic, I.3    Vrkic, N.4
  • 20
    • 33746764438 scopus 로고    scopus 로고
    • Identification errors involving clinical laboratories: A College of American Pathologists Q-Probes study of patient and specimen identification errors at 120 institutions
    • 16879009
    • Identification errors involving clinical laboratories: a College of American Pathologists Q-Probes study of patient and specimen identification errors at 120 institutions. Valenstein PN, Raab SS, Walsh MK, Arch Pathol Lab Med 2006 130 1106 1113 16879009
    • (2006) Arch Pathol Lab Med , vol.130 , pp. 1106-1113
    • Valenstein, P.N.1    Raab, S.S.2    Walsh, M.K.3
  • 21
    • 0034938879 scopus 로고    scopus 로고
    • Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories
    • 11408751
    • Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories. Polack B, Schved JF, Boneu B, Haemostasis 2001 31 61 68 11408751
    • (2001) Haemostasis , vol.31 , pp. 61-68
    • Polack, B.1    Schved, J.F.2    Boneu, B.3
  • 22
    • 2442490113 scopus 로고    scopus 로고
    • Current performance of patient sample collection in the UK
    • 10.1111/j.0958-7578.2004.0488.x 15113376
    • Current performance of patient sample collection in the UK. Murphy MF, Stearn BE, Dzik WH, Transfus Med 2004 14 113 121 10.1111/j.0958-7578.2004.0488.x 15113376
    • (2004) Transfus Med , vol.14 , pp. 113-121
    • Murphy, M.F.1    Stearn, B.E.2    Dzik, W.H.3
  • 23
    • 79959315519 scopus 로고    scopus 로고
    • Preanalytical errors: Some common errors in blood specimen collection for routine investigations in hospital patients
    • Preanalytical errors: some common errors in blood specimen collection for routine investigations in hospital patients. Nigam PK, Journal of Clinical and Diagnostic Research 2011 5 3 659 661
    • (2011) Journal of Clinical and Diagnostic Research , vol.5 , Issue.3 , pp. 659-661
    • Nigam, P.K.1
  • 24
    • 84897651089 scopus 로고    scopus 로고
    • Magee. Preanalytical variables in the chemistry laboratory
    • Accessed on February 14th 2012
    • Magee. Preanalytical variables in the chemistry laboratory. Leslie S, LabNotes 2005 15 1 Available at http://www.bd.com/vacutainer/labnotes/ Volume15Number1/. Accessed on February 14th 2012
    • (2005) LabNotes , vol.15 , Issue.1
    • Leslie, S.1
  • 25
    • 0036239525 scopus 로고    scopus 로고
    • Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists
    • 10.1309/PGM4-4F8L-2P1M-LKPB
    • Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists. Burns ER, Yoshikawa N, Lab Med 2002 33 378 380 10.1309/PGM4-4F8L-2P1M-LKPB
    • (2002) Lab Med , vol.33 , pp. 378-380
    • Burns, E.R.1    Yoshikawa, N.2
  • 26
    • 66249123892 scopus 로고    scopus 로고
    • A prospective study of causes of hemolysis during venipuncture: Tourniquet time should be kept to a minimum
    • 10.1258/acb.2009.008228 19389888
    • A prospective study of causes of hemolysis during venipuncture: tourniquet time should be kept to a minimum. Saleem S, Mani V, Chadwick MA, Creanor S, Ayling RM, Ann Clin Biochem 2009 46 244 246 10.1258/acb.2009.008228 19389888
    • (2009) Ann Clin Biochem , vol.46 , pp. 244-246
    • Saleem, S.1    Mani, V.2    Chadwick, M.A.3    Creanor, S.4    Ayling, R.M.5
  • 27
    • 79960130914 scopus 로고    scopus 로고
    • New ways to deal with known preanalytical issues: Use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry
    • 22135855
    • New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Manguera CLP, Sumita NM, Picheth G, Guidi GC, Scartezini M, Biochemia Medica 2011 21 2 152 159 22135855
    • (2011) Biochemia Medica , vol.21 , Issue.2 , pp. 152-159
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Manguera, C.L.P.5    Sumita, N.M.6    Picheth, G.7    Guidi, G.C.8    Scartezini, M.9
  • 28
    • 66249091255 scopus 로고    scopus 로고
    • Tourniquet application time during phlebotomy and the influence on clinical chemistry testing; Is it negligible?
    • Tourniquet application time during phlebotomy and the influence on clinical chemistry testing; is it negligible? Serdar MA, Kenar L, Haşim A, Koçu L, Türkmen YH, Kurt İ Akman Ş Erbil MK, Turk J Biochem 2008 33 3 85 88
    • (2008) Turk J Biochem , vol.33 , Issue.3 , pp. 85-88
    • Serdar, M.A.1    Kenar, L.2    Haşim, A.3    Koçu, L.4    Türkmen, Y.H.5    Kurt, I.6    Akman, S.7    Erbil, M.K.8
  • 29
    • 84897652105 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute (CLSI) CLSI, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898 USA: CLSI document H18-A4 (ISBN 1-56238-724-3)
    • Clinical and Laboratory Standards Institute (CLSI), Procedures for the Handling and Processing of Blood Specimens; Approved Guideline-Forth Edition CLSI, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898 USA: CLSI document H18-A4 (ISBN 1-56238-724-3) 2010
    • (2010) Procedures for the Handling and Processing of Blood Specimens; Approved Guideline - Forth Edition


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.