메뉴 건너뛰기




Volumn 8150 LNCS, Issue PART 2, 2013, Pages 336-344

Measurement of myelin in the preterm brain: Multi-compartment diffusion imaging and multi-component T2 relaxometry

Author keywords

[No Author keywords available]

Indexed keywords

ACCURATE ESTIMATION; ALGORITHMIC MODELLING; DIFFUSION IMAGING; MULTI-COMPONENT DIFFUSION; MYELIN WATER FRACTIONS; QUANTITATIVE IMAGING; SPATIAL ARRANGEMENTS; SPATIAL PATTERNS;

EID: 84897572587     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-40763-5_42     Document Type: Conference Paper
Times cited : (12)

References (10)
  • 1
    • 57149118216 scopus 로고    scopus 로고
    • Brain injury in premature infants: A complex amalgam of destructive and developmental disturbances
    • Volpe, J.J.: Brain injury in premature infants: a complex amalgam of destructive and developmental disturbances. Lancet Neurol. 8(1), 110-124 (2009)
    • (2009) Lancet Neurol. , vol.8 , Issue.1 , pp. 110-124
    • Volpe, J.J.1
  • 2
    • 0023177515 scopus 로고
    • Sequence of central nervous system myelination in human infancy. I. An autopsy study of myelination
    • Brody, B.A., Kinney, H.C., Kloman, A.S., Gilles, F.H.: Sequence of central nervous system myelination in human infancy. i. an autopsy study of myelination. J. Neuropathol Exp. Neurol. 46(3), 283-301 (1987)
    • (1987) J. Neuropathol Exp. Neurol. , vol.46 , Issue.3 , pp. 283-301
    • Brody, B.A.1    Kinney, H.C.2    Kloman, A.S.3    Gilles, F.H.4
  • 4
    • 67650033377 scopus 로고    scopus 로고
    • T2 at MR imaging is an objective quantitative measure of cerebral white matter signal intensity abnormality in preterm infants at term-equivalent age
    • Hagmann, C.F., Vita, E.D., Bainbridge, A., Gunny, R., Kapetanakis, A.B., Chong, W.K., Cady, E.B., Gadian, D.G., Robertson, N.J.: T2 at MR imaging is an objective quantitative measure of cerebral white matter signal intensity abnormality in preterm infants at term-equivalent age. Radiology 252(1), 209-217 (2009)
    • (2009) Radiology , vol.252 , Issue.1 , pp. 209-217
    • Hagmann, C.F.1    Vita, E.D.2    Bainbridge, A.3    Gunny, R.4    Kapetanakis, A.B.5    Chong, W.K.6    Cady, E.B.7    Gadian, D.G.8    Robertson, N.J.9
  • 6
    • 33846312869 scopus 로고    scopus 로고
    • Myelin water imaging in multiple sclerosis: Quantitative correlations with histopathology
    • Laule, C., Leung, E., Li, D., Traboulsee, A., Patya, D., MacKay, A., Moore, G.: Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology. Multiple Sclerosis 12, 747-753 (2006)
    • (2006) Multiple Sclerosis , vol.12 , pp. 747-753
    • Laule, C.1    Leung, E.2    Li, D.3    Traboulsee, A.4    Patya, D.5    MacKay, A.6    Moore, G.7
  • 8
    • 84861332834 scopus 로고    scopus 로고
    • Noddi: Practical in vivo neurite orientation dispersion and density imaging of the human brain
    • Zhang, H., Schneider, T., Wheeler-Kingshott, C.A., Alexander, D.C.: Noddi: practical in vivo neurite orientation dispersion and density imaging of the human brain. Neuroimage 61(4), 1000-1016 (2012)
    • (2012) Neuroimage , vol.61 , Issue.4 , pp. 1000-1016
    • Zhang, H.1    Schneider, T.2    Wheeler-Kingshott, C.A.3    Alexander, D.C.4
  • 9
    • 84861227345 scopus 로고    scopus 로고
    • Applications of stimulated echo correction to multicomponent T2 analysis
    • Prasloski, T., Maedler, B., Xiang, Q.-S., MacKay, A., Jones, C.: Applications of stimulated echo correction to multicomponent T2 analysis. Magn. Reson. Med. 67(6), 1803-1814 (2012)
    • (2012) Magn. Reson. Med. , vol.67 , Issue.6 , pp. 1803-1814
    • Prasloski, T.1    Maedler, B.2    Xiang, Q.-S.3    MacKay, A.4    Jones, C.5
  • 10
    • 77957322539 scopus 로고    scopus 로고
    • Transverse relaxometry with stimulated echo compensation
    • Lebel, R.M., Wilman, A.H.: Transverse relaxometry with stimulated echo compensation. Magn. Reson. Med. 64(4), 1005-1014 (2010)
    • (2010) Magn. Reson. Med. , vol.64 , Issue.4 , pp. 1005-1014
    • Lebel, R.M.1    Wilman, A.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.