메뉴 건너뛰기




Volumn 90, Issue , 2014, Pages 125-132

Disentangling the frequency and intensity dimensions of nuisance odour, and implications for jurisdictional odour impact criteria

Author keywords

Frequency; Intensity; Modelling criteria; Nuisance odour; Percentile

Indexed keywords

ATMOSPHERICS; EARTH ATMOSPHERE;

EID: 84897562160     PISSN: 13522310     EISSN: 18732844     Source Type: Journal    
DOI: 10.1016/j.atmosenv.2014.03.022     Document Type: Article
Times cited : (26)

References (30)
  • 1
    • 84897517178 scopus 로고    scopus 로고
    • Wiley, V. Belgiorno, V. Nadeo, T. Zarra (Eds.)
    • Odour Assessment Handbook 2012, Wiley. V. Belgiorno, V. Nadeo, T. Zarra (Eds.).
    • (2012) Odour Assessment Handbook
  • 4
    • 84897473648 scopus 로고    scopus 로고
    • Tech. Rep. 1509, Environmental Protection Authority of Victoria, Australia EPA of Victoria
    • EPA of Victoria Broiler Farm Odour Environmental Risk Assessment November 2012, Tech. Rep. 1509, Environmental Protection Authority of Victoria, Australia.
    • (2012) Broiler Farm Odour Environmental Risk Assessment
  • 8
    • 84897476900 scopus 로고    scopus 로고
    • Patterns in odour criterion percentiles and their implications for odour regulation
    • Clean Air Society of Australia and New Zealand (CASANZ), Perth, Australia, URL
    • Griffiths D. Patterns in odour criterion percentiles and their implications for odour regulation. 19th International Clean Air and Environment Conference 2009, Clean Air Society of Australia and New Zealand (CASANZ), Perth, Australia, URL. http://casanz.org.au.
    • (2009) 19th International Clean Air and Environment Conference
    • Griffiths, D.1
  • 9
    • 30644462222 scopus 로고    scopus 로고
    • Parameters for the assessment of odour impacts on communities
    • Henshaw P., Nicell J., Sikdar A. Parameters for the assessment of odour impacts on communities. Atmospheric Environment 2006, 40(6):1016-1029.
    • (2006) Atmospheric Environment , vol.40 , Issue.6 , pp. 1016-1029
    • Henshaw, P.1    Nicell, J.2    Sikdar, A.3
  • 11
    • 84897512689 scopus 로고    scopus 로고
    • Climate and Seismology - Average Windspeed Map 1971-2000.URL KNMI
    • KNMI Dutch National Database for Weather 2009, Climate and Seismology - Average Windspeed Map 1971-2000.URL. http://www.knmi.nl/klimatologie/normalen1971-2000/wind_jaargemiddelde.html.
    • (2009) Dutch National Database for Weather
  • 13
    • 0033626767 scopus 로고    scopus 로고
    • Exposure-annoyance relationships for odour from industrial sources
    • Miedema H.M., Walpot J., Vos H., Steunenberg C. Exposure-annoyance relationships for odour from industrial sources. Atmospheric Environment 2000, 34(18):2927-2936.
    • (2000) Atmospheric Environment , vol.34 , Issue.18 , pp. 2927-2936
    • Miedema, H.M.1    Walpot, J.2    Vos, H.3    Steunenberg, C.4
  • 14
    • 56449116045 scopus 로고    scopus 로고
    • Assessment and regulation of odour impacts
    • Nicell J.A. Assessment and regulation of odour impacts. Atmospheric Environment 2009, 43(1):196-206.
    • (2009) Atmospheric Environment , vol.43 , Issue.1 , pp. 196-206
    • Nicell, J.A.1
  • 15
    • 51349121835 scopus 로고    scopus 로고
    • Development and validating procedure of a formula to calculate a minimum separation distance from piggeries and poultry facilities to sensitive receptors
    • Nicolas J., Delva J., Cobut P., Romain A.-C. Development and validating procedure of a formula to calculate a minimum separation distance from piggeries and poultry facilities to sensitive receptors. Atmospheric Environment 2008, 42(30):7087-7095.
    • (2008) Atmospheric Environment , vol.42 , Issue.30 , pp. 7087-7095
    • Nicolas, J.1    Delva, J.2    Cobut, P.3    Romain, A.-C.4
  • 17
    • 84875265410 scopus 로고    scopus 로고
    • Assessment of separation distances to avoid odour annoyance: interaction between odour impact criteria and peak-to-mean factors
    • Schauberger G., Piringer M. Assessment of separation distances to avoid odour annoyance: interaction between odour impact criteria and peak-to-mean factors. Chemical Engineering Transactions 01 2012, 30.
    • (2012) Chemical Engineering Transactions , vol.30
    • Schauberger, G.1    Piringer, M.2
  • 18
    • 84897550583 scopus 로고    scopus 로고
    • Omnidirectional separation distance due to odour emission of livestock buildings calculated by the Austrian odour dispersion model (AODM)
    • American Society of Agricultural Engineers
    • Schauberger G., Piringer M., Petz E. Omnidirectional separation distance due to odour emission of livestock buildings calculated by the Austrian odour dispersion model (AODM). American Society of Agricultural Engineers Annual International Meeting 2000, American Society of Agricultural Engineers.
    • (2000) American Society of Agricultural Engineers Annual International Meeting
    • Schauberger, G.1    Piringer, M.2    Petz, E.3
  • 19
    • 33645236002 scopus 로고    scopus 로고
    • Odour episodes in the vicinity of livestock buildings: a qualitative comparison of odour complaint statistics with model calculations
    • Schauberger G., Piringer M., Petz E. Odour episodes in the vicinity of livestock buildings: a qualitative comparison of odour complaint statistics with model calculations. Agriculture, Ecosystems & Environment 2006, 114(24):185-194.
    • (2006) Agriculture, Ecosystems & Environment , vol.114 , Issue.24 , pp. 185-194
    • Schauberger, G.1    Piringer, M.2    Petz, E.3
  • 20
    • 84897482362 scopus 로고    scopus 로고
    • Weighting of odour sensation by the time of the day and time of the year to improve the reliability of the calculated separation distance
    • International Water Association, Barcelona
    • Schauberger G., Piringer M., Petz E. Weighting of odour sensation by the time of the day and time of the year to improve the reliability of the calculated separation distance. The 3rd International Water Association Odour and VOC Conference 2008, International Water Association, Barcelona.
    • (2008) The 3rd International Water Association Odour and VOC Conference
    • Schauberger, G.1    Piringer, M.2    Petz, E.3
  • 22
    • 0033854856 scopus 로고    scopus 로고
    • Odour nuisance and dispersion modelling: an objective approach to a very subjective problem
    • Simms K., Wilkinson S., Bethan S. Odour nuisance and dispersion modelling: an objective approach to a very subjective problem. Water Science and Technology 1999, 41(6):89-96.
    • (1999) Water Science and Technology , vol.41 , Issue.6 , pp. 89-96
    • Simms, K.1    Wilkinson, S.2    Bethan, S.3
  • 24
    • 40349116653 scopus 로고    scopus 로고
    • Odor frequency and odor annoyance. Part I: assessment of frequency, intensity and hedonic tone of environmental odors in the field
    • URL
    • Sucker K., Both R., Bischoff M., Guski R., Winneke G. Odor frequency and odor annoyance. Part I: assessment of frequency, intensity and hedonic tone of environmental odors in the field. International Archives of Occupational and Environmental Health 2008, 81:671-682. URL. 10.1007/s00420-007-0259-z.
    • (2008) International Archives of Occupational and Environmental Health , vol.81 , pp. 671-682
    • Sucker, K.1    Both, R.2    Bischoff, M.3    Guski, R.4    Winneke, G.5
  • 25
  • 29
    • 77954499980 scopus 로고    scopus 로고
    • Odour exposure criteria and odour modelling in western Australia
    • Wallis I., Cadee K. Odour exposure criteria and odour modelling in western Australia. Water 2008, 35(2):144-148.
    • (2008) Water , vol.35 , Issue.2 , pp. 144-148
    • Wallis, I.1    Cadee, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.