메뉴 건너뛰기




Volumn 28, Issue 3, 2014, Pages 651-658

Combination of flow reversal and distal filter for cerebral protection during carotid artery stenting

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN BLOOD FLOW; BRAIN HEMORRHAGE; BRAIN PERFUSION; BRAIN PROTECTION; CAROTID ARTERY OBSTRUCTION; CAROTID ARTERY STENTING; CEREBROVASCULAR ACCIDENT; CLINICAL EFFECTIVENESS; DEVICE SAFETY; DIFFUSION WEIGHTED IMAGING; DISTAL FILTER; EMBOLIC PROTECTION FILTER; EXTERNAL CAROTID ARTERY; EXTERNAL CAROTID ARTERY OCCLUSION; FEMALE; FEMORAL HEMATOMA; FLOW REVERSAL FILTER; GUIDING CATHETER; HEART INFARCTION; HEMATOMA; HUMAN; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; MORTALITY; OCCLUSION BALLOON CATHETER; OUTCOME ASSESSMENT; PRIORITY JOURNAL; VENOUS CIRCULATION; VERY ELDERLY; ADVERSE EFFECTS; BALLOON OCCLUSION; BLOOD FLOW; BRAIN ISCHEMIA; CAROTID STENOSIS; COMMON CAROTID ARTERY; COMPLICATION; DEVICES; EMBOLIC PROTECTION DEVICE; INTRACRANIAL EMBOLISM; PATHOPHYSIOLOGY; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; RADIOGRAPHY; RETROSPECTIVE STUDY; STENT; TREATMENT OUTCOME;

EID: 84897092873     PISSN: 08905096     EISSN: 16155947     Source Type: Journal    
DOI: 10.1016/j.avsg.2013.04.032     Document Type: Article
Times cited : (12)

References (19)
  • 1
    • 37849033524 scopus 로고    scopus 로고
    • Safety of carotid artery stenting for symptomatic carotid artery disease: A metaanalysis
    • Gurm HS, Nallamothu BK, Yadav J. Safety of carotid artery stenting for symptomatic carotid artery disease: a metaanalysis. Eur Heart J 2008;29:113-9.
    • (2008) Eur Heart J , vol.29 , pp. 113-119
    • Gurm, H.S.1    Nallamothu, B.K.2    Yadav, J.3
  • 2
    • 35348972924 scopus 로고    scopus 로고
    • In vitro performance assessment of distal protection devices for carotid artery stenting: Effect of physiological anatomy on vascular resistance
    • DOI 10.1583/1545-1550(2007)14[712:IVPAOD]2.0.CO;2
    • Siewiorek GM, Wholey MH, Finol EA. In vitro performance assessment of distal protection devices for carotid artery stenting: effect of physiological anatomy on vascular resistance. J Endovasc Ther 2007;14:712-24. (Pubitemid 47598199)
    • (2007) Journal of Endovascular Therapy , vol.14 , Issue.5 , pp. 712-724
    • Siewiorek, G.M.1    Wholey, M.H.2    Finol, E.A.3
  • 4
    • 84865775819 scopus 로고    scopus 로고
    • Significance of combining distal filter protection and a guiding catheter with temporary balloon occlusion for carotid artery stenting: Clinical results and evaluation of debris capture
    • Harada K, Morioka J, Higa T, et al. Significance of combining distal filter protection and a guiding catheter with temporary balloon occlusion for carotid artery stenting: clinical results and evaluation of debris capture. Ann Vasc Surg 2012;26:929-36.
    • (2012) Ann Vasc Surg , vol.26 , pp. 929-936
    • Harada, K.1    Morioka, J.2    Higa, T.3
  • 6
    • 34447308782 scopus 로고    scopus 로고
    • Periprocedural embolic events related to carotid artery stenting detected by diffusion-weighted MRI: Comparison between proximal and distal embolus protection devices
    • DOI 10.1583/06-1990.1
    • El-Koussy M, Schroth G, Do DD, et al. Periprocedural embolic events related to carotid artery stenting detected by diffusion-weighted MRI: comparison between proximal and distal embolus protection devices. J Endovasc Ther 2007;14:293-303. (Pubitemid 47057911)
    • (2007) Journal of Endovascular Therapy , vol.14 , Issue.3 , pp. 293-303
    • El-Koussy, M.1    Schroth, G.2    Do, D.-D.3    Gralla, J.4    Nedeltchev, K.5    Von Bredow, F.6    Remonda, L.7    Brekenfeld, C.8
  • 7
    • 80053632721 scopus 로고    scopus 로고
    • Microembolization during carotid artery stenting in patients with high-risk, lipid-rich plaque. A randomized trial of proximal versus distal cerebral protection
    • Montorsi P, Caputi L, Galli S, et al. Microembolization during carotid artery stenting in patients with high-risk, lipid-rich plaque. A randomized trial of proximal versus distal cerebral protection. J Am Coll Cardiol 2011;58:1656-63.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1656-1663
    • Montorsi, P.1    Caputi, L.2    Galli, S.3
  • 8
    • 84859435746 scopus 로고    scopus 로고
    • The PROFI study (Prevention of Cerebral Embolization by Proximal Balloon Occlusion Compared to Filter Protection During Carotid Artery Stenting): A prospective randomized trial
    • Bijuklic K, Wandler A, Hazizi F, et al. The PROFI study (Prevention of Cerebral Embolization by Proximal Balloon Occlusion Compared to Filter Protection During Carotid Artery Stenting): a prospective randomized trial. J Am Coll Cardiol 2012;59:1383-9.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1383-1389
    • Bijuklic, K.1    Wandler, A.2    Hazizi, F.3
  • 9
    • 27644511321 scopus 로고    scopus 로고
    • Silent cerebral ischemia detected with diffusion-weighted imaging in patients treated with protected and unprotected carotid artery stenting
    • DOI 10.1161/01.STR.0000185676.05358.f2
    • Cosottini M, Michelassi MC, Puglioli M, et al. Silent cerebral ischemia detected with diffusion-weighted imaging in patients treated with protected and unprotected carotid artery stenting. Stroke 2005;36:2389-93. (Pubitemid 41566964)
    • (2005) Stroke , vol.36 , Issue.11 , pp. 2389-2393
    • Cosottini, M.1    Michelassi, M.C.2    Puglioli, M.3    Lazzarotti, G.4    Orlandi, G.5    Marconi, F.6    Parenti, G.7    Bartolozzi, C.8
  • 10
    • 79952110448 scopus 로고    scopus 로고
    • Atherosclerotic plaque composition assessed by virtual histology intravascular ultrasound and cerebral embolization after carotid stenting
    • Timaran CH, Rosero EB, Martinez AE, et al. Atherosclerotic plaque composition assessed by virtual histology intravascular ultrasound and cerebral embolization after carotid stenting. J Vasc Surg 2010;52:1188-94.
    • (2010) J Vasc Surg , vol.52 , pp. 1188-1194
    • Timaran, C.H.1    Rosero, E.B.2    Martinez, A.E.3
  • 11
    • 77954255716 scopus 로고    scopus 로고
    • Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: Results from the ARMOUR pivotal trial
    • Ansel GM, Hopkins LN, Jaff MR, et al. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial. Catheter Cardiovasc Interv 2010;76:1-8.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 1-8
    • Ansel, G.M.1    Hopkins, L.N.2    Jaff, M.R.3
  • 14
    • 79951919875 scopus 로고    scopus 로고
    • Neuroprotection during carotid artery stenting using the GORE flow reversal system: 30-day outcomes in the EMPiRE Clinical Study
    • Clair DG, Hopkins LN, Mehta M, et al. Neuroprotection during carotid artery stenting using the GORE flow reversal system: 30-day outcomes in the EMPiRE Clinical Study. Catheter Cardiovasc Interv 2011;77:420-9.
    • (2011) Catheter Cardiovasc Interv , vol.77 , pp. 420-429
    • Clair, D.G.1    Hopkins, L.N.2    Mehta, M.3
  • 15
    • 8144220852 scopus 로고    scopus 로고
    • Effect of two different neuroprotection systems on microembolization during carotid artery stenting
    • Schmidt A, Diederich KW, Scheinert S, et al. Effect of two different neuroprotection systems on microembolization during carotid artery stenting. J Am Coll Cardiol 2004;44: 1966-9.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 1966-1969
    • Schmidt, A.1    Diederich, K.W.2    Scheinert, S.3
  • 16
    • 0035940384 scopus 로고    scopus 로고
    • Effect of the distal-balloon protection system on microembolization during carotid stenting
    • Al-Mubarak N, Roubin GS, Vitek JJ, et al. Effect of the distal-balloon protection system on microembolization during carotid stenting. Circulation 2001;104:1999-2002.
    • (2001) Circulation , vol.104 , pp. 1999-2002
    • Al-Mubarak, N.1    Roubin, G.S.2    Vitek, J.J.3
  • 17
    • 33748864628 scopus 로고    scopus 로고
    • Transcranial Doppler monitoring during stenting of the carotid bifurcation: Evaluation of two different distal protection devices in preventing embolization
    • Rubartelli P, Brusa G, Arrigo A, et al. Transcranial Doppler monitoring during stenting of the carotid bifurcation: evaluation of two different distal protection devices in preventing embolization. J Endovasc Ther 2006;13:436-42.
    • (2006) J Endovasc Ther , vol.13 , pp. 436-442
    • Rubartelli, P.1    Brusa, G.2    Arrigo, A.3
  • 18
    • 33750961663 scopus 로고    scopus 로고
    • Transcranial Doppler monitoring of transcervical carotid stenting with flow reversal protection: A novel carotid revascularization technique
    • Ribo M, Molina CA, Alvarez B, et al. Transcranial Doppler monitoring of transcervical carotid stenting with flow reversal protection: a novel carotid revascularization technique. Stroke 2006;37:2846-9.
    • (2006) Stroke , vol.37 , pp. 2846-2849
    • Ribo, M.1    Molina, C.A.2    Alvarez, B.3
  • 19
    • 77958484649 scopus 로고    scopus 로고
    • Routine use of debris aspiration before retrieval of distal filter protection devices in carotid arterial stenting: Analysis of captured debris and evaluation of clinical results
    • Sorimachi T, Nishino K, Shimbo J, et al. Routine use of debris aspiration before retrieval of distal filter protection devices in carotid arterial stenting: analysis of captured debris and evaluation of clinical results. Neurosurg 2010;67:1260-7.
    • (2010) Neurosurg , vol.67 , pp. 1260-1267
    • Sorimachi, T.1    Nishino, K.2    Shimbo, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.