메뉴 건너뛰기




Volumn 9, Issue 3, 2014, Pages

Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL RADIOGRAPHY; ADULT; AGED; ARTICLE; ARTIFACT REDUCTION; BREATHING MECHANICS; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; FEASIBILITY STUDY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; INTERMETHOD COMPARISON; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PANCREATOGRAPHY; PARALLEL TRANSMIT ARRAY; RADIATION EQUIPMENT; RADIOFREQUENCY RADIATION; RETROSPECTIVE STUDY; SINGLE SHOT ECHO PLANAR IMAGING; WHOLE BODY SCANNER; ZOOMED DIFFUSION WEIGHTED ECHO PLANAR IMAGING; PANCREAS; PATHOLOGY;

EID: 84897086228     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0089468     Document Type: Article
Times cited : (50)

References (23)
  • 1
    • 61349123591 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging as a cancer biomarker: Consensus and recommendations
    • Padhani AR, Liu G, Koh DM, Chenevert TL, Thoeny HC, et al. (2009) Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11: 102-125.
    • (2009) Neoplasia , vol.11 , pp. 102-125
    • Padhani, A.R.1    Liu, G.2    Koh, D.M.3    Chenevert, T.L.4    Thoeny, H.C.5
  • 3
    • 44449177080 scopus 로고    scopus 로고
    • Renal masses: Characterization with diffusion-weighted MR imaging - A preliminary experience
    • Zhang J, Tehrani YM, Wang L, Ishill NM, Schwartz LH, et al. (2008) Renal masses: characterization with diffusion-weighted MR imaging - a preliminary experience. Radiology 247: 458-464.
    • (2008) Radiology , vol.247 , pp. 458-464
    • Zhang, J.1    Tehrani, Y.M.2    Wang, L.3    Ishill, N.M.4    Schwartz, L.H.5
  • 4
    • 61749088918 scopus 로고    scopus 로고
    • Short- and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen
    • Braithwaite AC, Dale BM, Boll DT, Merkle EM (2009) Short- and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen. Radiology 250: 459-465.
    • (2009) Radiology , vol.250 , pp. 459-465
    • Braithwaite, A.C.1    Dale, B.M.2    Boll, D.T.3    Merkle, E.M.4
  • 5
    • 84895844229 scopus 로고    scopus 로고
    • Characterization of focal pancreatic lesions using normalized apparent diffusion coefficient at 1.5-Tesla: Preliminary experience
    • Barral M, Sebbag-Sfez D, Hoeffel C, Chaput U, Dohan A, et al. (2013) Characterization of focal pancreatic lesions using normalized apparent diffusion coefficient at 1.5-Tesla: preliminary experience. Diagn Interv Imaging 94: 619-627.
    • (2013) Diagn Interv Imaging , vol.94 , pp. 619-627
    • Barral, M.1    Sebbag-Sfez, D.2    Hoeffel, C.3    Chaput, U.4    Dohan, A.5
  • 6
    • 58149359590 scopus 로고    scopus 로고
    • Assessment of chronic pancreatitis: Utility of diffusion-weighted MR imaging with secretin enhancement
    • Akisik MF, Aisen AM, Sandrasegaran K, Jennings SG, Lin C, et al. (2009) Assessment of chronic pancreatitis: utility of diffusion-weighted MR imaging with secretin enhancement. Radiology 250: 103-109.
    • (2009) Radiology , vol.250 , pp. 103-109
    • Akisik, M.F.1    Aisen, A.M.2    Sandrasegaran, K.3    Jennings, S.G.4    Lin, C.5
  • 7
    • 78650662638 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging of pancreatic adenocarcinomas: Association with histopathology and tumor grade
    • Wang Y, Chen ZE, Nikolaidis P, McCarthy RJ, Merrick L, et al. (2011) Diffusion-weighted magnetic resonance imaging of pancreatic adenocarcinomas: association with histopathology and tumor grade. J Magn Reson Imaging 33: 136-142.
    • (2011) J Magn Reson Imaging , vol.33 , pp. 136-142
    • Wang, Y.1    Chen, Z.E.2    Nikolaidis, P.3    McCarthy, R.J.4    Merrick, L.5
  • 9
    • 78650694093 scopus 로고    scopus 로고
    • Intravoxel incoherent motion MRI for the differentiation between mass forming chronic pancreatitis and pancreatic carcinoma
    • Klauss M, Lemke A, Grunberg K, Simon D, Re TJ, et al. (2011) Intravoxel incoherent motion MRI for the differentiation between mass forming chronic pancreatitis and pancreatic carcinoma. Invest Radiol 46: 57-63.
    • (2011) Invest Radiol , vol.46 , pp. 57-63
    • Klauss, M.1    Lemke, A.2    Grunberg, K.3    Simon, D.4    Re, T.J.5
  • 10
    • 0032875761 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: Preliminary clinical experience in 61 patients
    • DOI 10.1007/s002619900539
    • Ichikawa T, Haradome H, Hachiya J, Nitatori T, Araki T (1999) Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients. Abdom Imaging 24: 456-461. (Pubitemid 29411497)
    • (1999) Abdominal Imaging , vol.24 , Issue.5 , pp. 456-461
    • Ichikawa, T.1    Haradome, H.2    Hachiya, J.3    Nitatori, T.4    Araki, T.5
  • 11
    • 55749097922 scopus 로고    scopus 로고
    • Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver
    • Kwee TC, Takahara T, Koh DM, Nievelstein RA, Luijten PR (2008) Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver. J Magn Reson Imaging 28: 1141-1148.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1141-1148
    • Kwee, T.C.1    Takahara, T.2    Koh, D.M.3    Nievelstein, R.A.4    Luijten, P.R.5
  • 12
    • 84864686885 scopus 로고    scopus 로고
    • Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values
    • Bilgili MY (2012) Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values. Eur J Radiol 81: 2066-2068.
    • (2012) Eur J Radiol , vol.81 , pp. 2066-2068
    • Bilgili, M.Y.1
  • 13
    • 33745331084 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of the liver: Technical challenges and prospects for the future
    • Naganawa S, Kawai H, Fukatsu H, Sakurai Y, Aoki I, et al. (2005) Diffusion-weighted imaging of the liver: technical challenges and prospects for the future. Magn Reson Med Sci 4: 175-186.
    • (2005) Magn Reson Med Sci , vol.4 , pp. 175-186
    • Naganawa, S.1    Kawai, H.2    Fukatsu, H.3    Sakurai, Y.4    Aoki, I.5
  • 14
    • 0023678634 scopus 로고
    • Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging
    • Le Bihan D, Breton E, Lallemand D, Aubin ML, Vignaud J, et al. (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168: 497-505.
    • (1988) Radiology , vol.168 , pp. 497-505
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3    Aubin, M.L.4    Vignaud, J.5
  • 15
    • 84877929164 scopus 로고    scopus 로고
    • Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T
    • Morelli J, Porter D, Ai F, Gerdes C, Saettele M, et al. (2013) Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T. Acta Radiol.
    • (2013) Acta Radiol
    • Morelli, J.1    Porter, D.2    Ai, F.3    Gerdes, C.4    Saettele, M.5
  • 16
    • 0036260582 scopus 로고    scopus 로고
    • Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging
    • DOI 10.1002/mrm.10157
    • Rieseberg S, Frahm J, Finsterbusch J (2002) Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging. Magn Reson Med 47: 1186-1193. (Pubitemid 34587410)
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.6 , pp. 1186-1193
    • Rieseberg, S.1    Frahm, J.2    Finsterbusch, J.3
  • 17
    • 0036743788 scopus 로고    scopus 로고
    • Zoomed functional imaging in the human brain at 7 Tesla with simultaneous high spatial and high temporal resolution
    • Pfeuffer J, van de Moortele PF, Yacoub E, Shmuel A, Adriany G, et al. (2002) Zoomed functional imaging in the human brain at 7 Tesla with simultaneous high spatial and high temporal resolution. Neuroimage 17: 272-286.
    • (2002) Neuroimage , vol.17 , pp. 272-286
    • Pfeuffer, J.1    Van De Moortele, P.F.2    Yacoub, E.3    Shmuel, A.4    Adriany, G.5
  • 19
    • 1842586446 scopus 로고    scopus 로고
    • Parallel excitation with an array of transmit coils
    • Zhu Y (2004) Parallel excitation with an array of transmit coils. Magn Reson Med 51: 775-784.
    • (2004) Magn Reson Med , vol.51 , pp. 775-784
    • Zhu, Y.1
  • 20
    • 84883397571 scopus 로고    scopus 로고
    • Added value of diffusion-weighted imaging to MR cholangiopancreatography with unenhanced MR imaging for predicting malignancy or invasiveness of intraductal papillary mucinous neoplasm of the pancreas
    • Kang KM, Lee JM, Shin CI, Baek JH, Kim SH, et al. (2013) Added value of diffusion-weighted imaging to MR cholangiopancreatography with unenhanced MR imaging for predicting malignancy or invasiveness of intraductal papillary mucinous neoplasm of the pancreas. J Magn Reson Imaging.
    • (2013) J Magn Reson Imaging
    • Kang, K.M.1    Lee, J.M.2    Shin, C.I.3    Baek, J.H.4    Kim, S.H.5
  • 21
    • 84875463805 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of the healthy pancreas: ADC values are age and gender dependent
    • Herrmann J, Schoennagel BP, Roesch M, Busch JD, Derlin T, et al. (2013) Diffusion-weighted imaging of the healthy pancreas: ADC values are age and gender dependent. J Magn Reson Imaging 37: 886-891.
    • (2013) J Magn Reson Imaging , vol.37 , pp. 886-891
    • Herrmann, J.1    Schoennagel, B.P.2    Roesch, M.3    Busch, J.D.4    Derlin, T.5
  • 22
    • 84857677935 scopus 로고    scopus 로고
    • Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen
    • Rao RK, Riffel P, Meyer M, Kettnaker PJ, Lemke A, et al. (2012) Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen. PLoS One 7: e32613.
    • (2012) PLoS One , vol.7
    • Rao, R.K.1    Riffel, P.2    Meyer, M.3    Kettnaker, P.J.4    Lemke, A.5
  • 23
    • 84878187987 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging of the normal pancreas: Reproducibility and variations of apparent diffusion coefficient measurement at 1.5- and 3.0-Tesla
    • Barral M, Soyer P, Ben Hassen W, Gayat E, Aout M, et al. (2013) Diffusion-weighted MR imaging of the normal pancreas: reproducibility and variations of apparent diffusion coefficient measurement at 1.5- and 3.0-Tesla. Diagn Interv Imaging 94: 418-427.
    • (2013) Diagn Interv Imaging , vol.94 , pp. 418-427
    • Barral, M.1    Soyer, P.2    Ben Hassen, W.3    Gayat, E.4    Aout, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.