메뉴 건너뛰기




Volumn 33, Issue 4, 2014, Pages 422-428

Extended in vivo evaluation of a miniaturized axial flow pump with a novel inflow cannula for a minimal invasive implantation procedure

Author keywords

atrial cannulation; LVAD; miniaturized; minimal invasive

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; AUTOPSY; BLOOD CLOTTING; CANNULA; IN VIVO STUDY; LEFT VENTRICULAR ASSIST DEVICE; MINIMALLY INVASIVE PROCEDURE; MITRAL VALVE DISEASE; NONHUMAN; POSTOPERATIVE COMPLICATION; POSTOPERATIVE HEMORRHAGE; PRIORITY JOURNAL; PULMONARY VEIN; SHEEP; ULTRASOUND; ANIMAL; CATHETER; DEVICE FAILURE ANALYSIS; ELECTRONICS; FEMALE; HEART ASSIST DEVICE; HEART ATRIUM; HEMODYNAMICS; HUMAN; MATERIALS TESTING; MINIMALLY INVASIVE SURGERY; MITRAL VALVE; PATHOLOGY; PHYSIOLOGY; PROSTHESIS; SURGERY; THORACOTOMY;

EID: 84897075704     PISSN: 10532498     EISSN: 15573117     Source Type: Journal    
DOI: 10.1016/j.healun.2013.10.032     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 84863393498 scopus 로고    scopus 로고
    • The Fourth INTERMACS Annual Report: 4,000 implants and counting
    • J.K. Kirklin, D.C. Naftel, and R.L. Kormos et al. The Fourth INTERMACS Annual Report: 4,000 implants and counting J Heart Lung Transplant 31 2012 117 126
    • (2012) J Heart Lung Transplant , vol.31 , pp. 117-126
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3
  • 2
    • 78049287188 scopus 로고    scopus 로고
    • Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial
    • G.M. Wieselthaler, OD G, P. Jansz, A. Khaghani, and M. Strueber Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial J Heart Lung Transplant 29 2010 1218 1225
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1218-1225
    • Wieselthaler, G.M.1    Op, D.G.2    Jansz, P.3    Khaghani, A.4    Strueber, M.5
  • 3
    • 77950897411 scopus 로고    scopus 로고
    • Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients
    • J.G. Rogers, K.D. Aaronson, and A.J. Boyle et al. Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients J Am Coll Cardiol 55 2010 1826 1834
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1826-1834
    • Rogers, J.G.1    Aaronson, K.D.2    Boyle, A.J.3
  • 4
    • 84863195802 scopus 로고    scopus 로고
    • Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation
    • K.D. Aaronson, M.S. Slaughter, and L.W. Miller et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation Circulation 125 2012 3191 3200
    • (2012) Circulation , vol.125 , pp. 3191-3200
    • Aaronson, K.D.1    Slaughter, M.S.2    Miller, L.W.3
  • 6
    • 79953070598 scopus 로고    scopus 로고
    • Off-pump implantation of the HeartWare HVAD left ventricular assist device through minimally invasive incisions
    • A. Cheung, Y. Lamarche, and A. Kaan et al. Off-pump implantation of the HeartWare HVAD left ventricular assist device through minimally invasive incisions Ann Thorac Surg 91 2011 1294 1296
    • (2011) Ann Thorac Surg , vol.91 , pp. 1294-1296
    • Cheung, A.1    Lamarche, Y.2    Kaan, A.3
  • 7
    • 33646162657 scopus 로고    scopus 로고
    • Initial experience with non-thoracic, extraperitoneal, off-pump insertion of the Jarvik 2000 Heart in patients with previous median sternotomy
    • O.H. Frazier, I.D. Gregoric, and W.E. Cohn Initial experience with non-thoracic, extraperitoneal, off-pump insertion of the Jarvik 2000 Heart in patients with previous median sternotomy J Heart Lung Transplant 25 2006 499 503
    • (2006) J Heart Lung Transplant , vol.25 , pp. 499-503
    • Frazier, O.H.1    Gregoric, I.D.2    Cohn, W.E.3
  • 9
    • 33845803269 scopus 로고    scopus 로고
    • Hemodynamic effects of partial ventricular support in chronic heart failure: Results of simulation validated with in vivo data
    • D. Morley, K. Litwak, and P. Ferber et al. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data J Thorac Cardiovasc Surg 133 2007 21 28
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 21-28
    • Morley, D.1    Litwak, K.2    Ferber, P.3
  • 10
    • 65749118734 scopus 로고    scopus 로고
    • HeartWare miniature axial-flow ventricular assist device: Design and initial feasibility test
    • M.S. Slaughter, M.A. Sobieski 2nd, and D. Tamez et al. HeartWare miniature axial-flow ventricular assist device: design and initial feasibility test Tex Heart Inst J 36 2009 12 16
    • (2009) Tex Heart Inst J , vol.36 , pp. 12-16
    • Slaughter, M.S.1    Sobieski II, M.A.2    Tamez, D.3
  • 11
    • 79954589537 scopus 로고    scopus 로고
    • Clinical benefits of partial circulatory support in New York Heart Association class IIIB and early class IV patients
    • B.P. Meyns, A. Simon, and S. Klotz et al. Clinical benefits of partial circulatory support in New York Heart Association class IIIB and early class IV patients Eur J Cardiothorac Surg 39 2011 693 698
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 693-698
    • Meyns, B.P.1    Simon, A.2    Klotz, S.3
  • 12
    • 80051799841 scopus 로고    scopus 로고
    • Transapical miniaturized ventricular assist device: Design and initial testing
    • M.S. Slaughter, G.A. Giridharan, and D. Tamez et al. Transapical miniaturized ventricular assist device: design and initial testing J Thorac Cardiovasc Surg 142 2011 668 674
    • (2011) J Thorac Cardiovasc Surg , vol.142 , pp. 668-674
    • Slaughter, M.S.1    Giridharan, G.A.2    Tamez, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.