메뉴 건너뛰기




Volumn 5, Issue 4, 2014, Pages 1124-1135

Robust efficient estimation of heart rate pulse from video

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; OXIMETERS;

EID: 84896993587     PISSN: None     EISSN: 21567085     Source Type: Journal    
DOI: 10.1364/BOE.5.001124     Document Type: Article
Times cited : (81)

References (20)
  • 1
    • 0028044634 scopus 로고
    • A review of the principles of pulse oximetry and accuracy of pulse oximeter estimates during exercise
    • L. J. Mengelkoch, D. Martin, and J. Lawler, A review of the principles of pulse oximetry and accuracy of pulse oximeter estimates during exercise, Phys. Ther. 74, 40-49 (1994).
    • (1994) Phys. Ther , vol.74 , pp. 40-49
    • Mengelkoch, L.J.1    Martin, D.2    Lawler, J.3
  • 3
    • 84896948428 scopus 로고    scopus 로고
    • Https://play.google.com/store/apps/details?id=si.modula.android.instantheartrate&feature=relatedapps.
  • 4
    • 34250201117 scopus 로고    scopus 로고
    • Heart rate measurement based on a time-lapse image
    • C. Takano and Y. Ohta, Heart rate measurement based on a time-lapse image, Med. Engin. Phys. 29, 853-857 (2007).
    • (2007) Med. Engin. Phys , vol.29 , pp. 853-857
    • Takano, C.1    Ohta, Y.2
  • 5
    • 34247566713 scopus 로고    scopus 로고
    • Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetry
    • K. Humphreys, T. Ward, and C. Markham, Noncontact simultaneous dual wavelength photoplethysmography: a further step toward noncontact pulse oximetry, Rev. Sci. Instrum. 78, 044304 (2007).
    • (2007) Rev. Sci. Instrum , vol.78 , pp. 044304
    • Humphreys, K.1    Ward, T.2    Markham, C.3
  • 7
    • 77952701951 scopus 로고    scopus 로고
    • Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
    • M.-Z. Poh, D. J. McDuff, and R. W. Picard, Non-contact, automated cardiac pulse measurements using video imaging and blind source separation, Optics Express 18, 10762-10774 (2010).
    • (2010) Optics Express , vol.18 , pp. 10762-10774
    • Poh, M.-Z.1    McDuff, D.J.2    Picard, R.W.3
  • 8
    • 79551572458 scopus 로고    scopus 로고
    • Advancements in noncontact, multiparameter physiological measure- ments using a webcam
    • M.-Z. Poh, D. J. McDuff, and R. Picard, Advancements in noncontact, multiparameter physiological measure- ments using a webcam, IEEE Trans. Biomed. Eng. 58, 7-11 (2011).
    • (2011) IEEE Trans. Biomed. Eng , vol.58 , pp. 7-11
    • Poh, M.-Z.1    McDuff, D.J.2    Picard, R.3
  • 10
    • 84897014359 scopus 로고    scopus 로고
    • Https://play.google.com/store/apps/details?id=com.vitrox.facion.gui&hl=en.
  • 16
    • 58149112508 scopus 로고    scopus 로고
    • Remote plethysmographic imaging using ambient light
    • W. Verkruysse, L. O. Svaasand, and J. S. Nelson, Remote plethysmographic imaging using ambient light, Opt. Express 16, 21434-21445 (2008).
    • (2008) Opt. Express , vol.16 , pp. 21434-21445
    • Verkruysse, W.1    Svaasand, L.O.2    Nelson, J.S.3
  • 18
    • 84896948124 scopus 로고    scopus 로고
    • Http://www.santamedical.net/servlet/the-243/Finger-Pulse-Oximeter-SM-dsh-110/Detail.
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J. Martin Bland and D. Altman, Statistical methods for assessing agreement between two methods of clinical measurement, The lancet 327, 307-310 (1986).
    • (1986) The Lancet , vol.327 , pp. 307-310
    • Martin Bland, J.1    Altman, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.