-
1
-
-
0022559358
-
An X-band microwave life-detection system
-
Jul.
-
K. M. Chen, D. Misra, H. Wang, H. R. Chuang, and E. Postow, "An X-band microwave life-detection system, " IEEE Trans. Biomed. Eng., vol. BME-33, no. 7, pp. 697-702, Jul. 1986.
-
(1986)
IEEE Trans. Biomed. Eng.
, vol.BME-33
, Issue.7
, pp. 697-702
-
-
Chen, K.M.1
Misra, D.2
Wang, H.3
Chuang, H.R.4
Postow, E.5
-
2
-
-
79955732195
-
Recent advances in Doppler radar sensors for pervasive healthcare monitoring
-
Yokohama, Japan, Dec.
-
C. Li and J. Lin, "Recent advances in Doppler radar sensors for pervasive healthcare monitoring, " in Proc. 22nd Asia-Pacific Microw. Conf., Yokohama, Japan, Dec. 2010, pp. 283-290.
-
(2010)
Proc. 22nd Asia-Pacific Microw. Conf
, pp. 283-290
-
-
Li, C.1
Lin, J.2
-
3
-
-
0033962823
-
Microwave life-detection systems for searching human subjects under earthquake rubble and behind barrier
-
Jan.
-
K. M. Chen, Y. Huang, J. Zhang, and A. Norman, "Microwave life-detection systems for searching human subjects under earthquake rubble and behind barrier, " IEEE Trans. Biomed. Eng., vol. 47, no. 1, pp. 106-114, Jan. 2000.
-
(2000)
IEEE Trans. Biomed. Eng.
, vol.47
, Issue.1
, pp. 106-114
-
-
Chen, K.M.1
Huang, Y.2
Zhang, J.3
Norman, A.4
-
4
-
-
1842527440
-
Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring
-
Mar.
-
A. D. Droitcour, O. Boric-Lubecke, V. M. Lubecke, J. Lin, and G. T. A. Kovacs, "Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring, " IEEE Trans. Microw. Theory Tech., vol. 52, no. 3, pp. 838-848, Mar. 2004.
-
(2004)
IEEE Trans. Microw. Theory Tech.
, vol.52
, Issue.3
, pp. 838-848
-
-
Droitcour, A.D.1
Boric-Lubecke, O.2
Lubecke, V.M.3
Lin, J.4
Kovacs, G.T.A.5
-
5
-
-
77955088059
-
A remote compact sensor for the real-time monitoring of human heartbeat and respiration rate
-
Jun.
-
J. H. Choi and D. K. Kim, "A remote compact sensor for the real-time monitoring of human heartbeat and respiration rate, " IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 3, pp. 181-188, Jun. 2009.
-
(2009)
IEEE Trans. Biomed. Circuits Syst.
, vol.3
, Issue.3
, pp. 181-188
-
-
Choi, J.H.1
Kim, D.K.2
-
6
-
-
67650514267
-
System level integration of handheld wireless non-contact vital sign detectors
-
Jan.
-
X. Yu, C. Li, and J. Lin, "System level integration of handheld wireless non-contact vital sign detectors, " in Proc. IEEE Radio Wireless Symp., Jan. 2009, pp. 514-517.
-
(2009)
Proc. IEEE Radio Wireless Symp
, pp. 514-517
-
-
Yu, X.1
Li, C.2
Lin, J.3
-
7
-
-
57849157376
-
Random body movement cancellation in Doppler radar vital sign detection
-
Dec.
-
C. Li and J. Lin, "Random body movement cancellation in Doppler radar vital sign detection, " IEEE Trans. Microw. Theory Tech., vol. 56, no. 12, pp. 3143-3152, Dec. 2008.
-
(2008)
IEEE Trans. Microw. Theory Tech.
, vol.56
, Issue.12
, pp. 3143-3152
-
-
Li, C.1
Lin, J.2
-
8
-
-
79956365095
-
A real-time heart rate analysis for a remote millimeter wave I-Q sensor
-
Jun.
-
S. Bakhtiari, S. Liao, T. W. Elmer, N. Gopalsami, and A. C. Raptis, "A real-time heart rate analysis for a remote millimeter wave I-Q sensor, " IEEE Trans. Biomed. Eng., vol. 58, no. 6, pp. 1839-1845, Jun. 2011.
-
(2011)
IEEE Trans. Biomed. Eng.
, vol.58
, Issue.6
, pp. 1839-1845
-
-
Bakhtiari, S.1
Liao, S.2
Elmer, T.W.3
Gopalsami, N.4
Raptis, A.C.5
-
9
-
-
76849109848
-
Accurate Doppler radar non-contact vital sign detection using the RELAX algorithm
-
Mar.
-
C. Li, J. Ling, J. Li, and J. Lin, "Accurate Doppler radar non-contact vital sign detection using the RELAX algorithm, " IEEE Trans. Instrum. Meas., vol. 59, no. 3, pp. 687-695, Mar. 2010.
-
(2010)
IEEE Trans. Instrum. Meas.
, vol.59
, Issue.3
, pp. 687-695
-
-
Li, C.1
Ling, J.2
Li, J.3
Lin, J.4
-
10
-
-
52149102960
-
Novel signal processing techniques for Doppler radar cardiopulmonary sensing
-
Jan.
-
D. R. Morgan and M. G. Zierdt, "Novel signal processing techniques for Doppler radar cardiopulmonary sensing, " Signal Process., vol. 89, no. 1, pp. 45-66, Jan. 2009.
-
(2009)
Signal Process.
, vol.89
, Issue.1
, pp. 45-66
-
-
Morgan, D.R.1
Zierdt, M.G.2
-
11
-
-
70350187066
-
Assessment of heart rate variability and respiratory sinus arrhythmia via Doppler radar
-
Oct.
-
W. Massagram, V. Lubecke, A. Host-Madsen, and O. Boric-Lubecke, "Assessment of heart rate variability and respiratory sinus arrhythmia via Doppler radar, " IEEE Trans. Microw. Theory Tech., vol. 57, no. 10, pp. 2542-2549, Oct. 2009.
-
(2009)
IEEE Trans. Microw. Theory Tech.
, vol.57
, Issue.10
, pp. 2542-2549
-
-
Massagram, W.1
Lubecke, V.2
Host-Madsen, A.3
Boric-Lubecke, O.4
-
12
-
-
84860559439
-
Antenna array technology for radar respiration measurement in motion-adaptive lung cancer radiotherapy
-
Santa Clara, CA, Jan.
-
C. Gu, Z. Salmani, H. Zhang, and C. Li, "Antenna array technology for radar respiration measurement in motion-adaptive lung cancer radiotherapy, " in Proc. BioWireleSS, Santa Clara, CA, Jan. 2012, pp. 15-18.
-
(2012)
Proc. BioWireleSS
, pp. 15-18
-
-
Gu, C.1
Salmani, Z.2
Zhang, H.3
Li, C.4
-
13
-
-
84875148237
-
Physical working principles of medical radar
-
Apr.
-
O. Aardal, Y. Paichard, S. Brovoll, T. Berger, T. S. Lande, and S. Hamran, "Physical working principles of medical radar, " IEEE Trans. Biomed. Eng., vol. 60, no. 4, pp. 1142-1149, Apr. 2013.
-
(2013)
IEEE Trans. Biomed. Eng.
, vol.60
, Issue.4
, pp. 1142-1149
-
-
Aardal, O.1
Paichard, Y.2
Brovoll, S.3
Berger, T.4
Lande, T.S.5
Hamran, S.6
-
14
-
-
0024729058
-
Three-dimensional reconstruction of cardiac displacement patterns on the chest wall during the P, QRS and T-segments of the ECG by laser speckle interferometry
-
G. Ramachandran and M. Singh, "Three-dimensional reconstruction of cardiac displacement patterns on the chest wall during the P, QRS, and T-segments of the ECG by laser speckle interferometry, " Med. Biological Eng. Comput., vol. 27, no. 5, pp. 525-530, 1989. (Pubitemid 19236191)
-
(1989)
Medical and Biological Engineering and Computing
, vol.27
, Issue.5
, pp. 525-530
-
-
Ramachandran, G.1
Singh, M.2
-
15
-
-
0021412482
-
Laser method for recording displacement of the heart and chest wall
-
A. E. Aubert, L. Welkenhuysen, J. Montald, L. de Wolf, H. Geivers, J. Minten, H. Kesteloot, and H. Geest, "Laser method for recording displacement of the heart and chest wall, " J. Biomed. Eng., vol. 6, no. 2, pp. 134-140, 1984. (Pubitemid 14134476)
-
(1984)
Journal of Biomedical Engineering
, vol.6
, Issue.2
, pp. 134-140
-
-
Aubert, A.E.1
Welkenhuysen, L.2
Montald, J.3
-
16
-
-
34248198847
-
-
IEEE Trans. Microw. Theory Tech. May
-
B. Park, O. Boric-Lubecke, and V. M. Lubecke, "Arctangent demodulation with DC offset compensation in quadrature Doppler radar receiver systems, " IEEE Trans. Microw. Theory Tech., vol. 55, no. 5, pp. 1073-1079, May 2007.
-
(2007)
Arctangent Demodulation With Dc Offset Compensation In Quadrature Doppler Radar Receiver Systems
, vol.55
, Issue.5
, pp. 1073-1079
-
-
Park, B.1
Boric-Lubecke, O.2
Lubecke, V.M.3
-
17
-
-
0019478188
-
The correction of i and Q errors in a coherent processor
-
Jan.
-
F. E. Churchill, G. W. Ogar, and B. J. Thompson, "The correction of I and Q errors in a coherent processor, " IEEE Trans. Aerosp. Electron. Syst., vol. AES-17, no. 1, pp. 131-137, Jan. 1981.
-
(1981)
IEEE Trans. Aerosp. Electron. Syst
, vol.AES-17
, Issue.1
, pp. 131-137
-
-
Churchill, F.E.1
Ogar, G.W.2
Thompson, B.J.3
-
18
-
-
5444236478
-
The empirical mode decomposition and the Hubert spectrum for nonlinear and non-stationary time series analysis
-
N. Huang, Z. Shen, S. Long, M. C. Wu, H. Shih, Q. Zheng, N. Yen, C. Tung, and H. Liu, "The empirical mode decomposition and the Hilbert spectrum for nonlinear and nonstationary time series analysis, " Proc. Roy. Soc. London, vol. 454, no. 1971, pp. 903-995, Mar. 1998. (Pubitemid 128733183)
-
(1998)
Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
, vol.454
, Issue.1971
, pp. 903-995
-
-
Huang, N.E.1
Shen, Z.2
Long, S.R.3
Wu, M.C.4
Snin, H.H.5
Zheng, Q.6
Yen, N.-C.7
Tung, C.C.8
Liu, H.H.9
-
19
-
-
80052078099
-
Ensemble empirical mode decomposition: A noise-assisted data analysis method
-
Z. Wu and N. E. Huang, "Ensemble empirical mode decomposition: A noise-assisted data analysis method, " Advances Adaptive Data Anal., vol. 1, no. 1, pp. 1-41, 2009.
-
(2009)
Advances Adaptive Data Anal.
, vol.1
, Issue.1
, pp. 1-41
-
-
Wu, Z.1
Huang, N.E.2
-
20
-
-
84863095122
-
A comparative study of pulse rate variability and heart rate variability in healthy subjects
-
J. S. Wong, W. A. Lu, K. T. Wu, M. Liu, G. Y. Chen, and C. D. Kuo, "A comparative study of pulse rate variability and heart rate variability in healthy subjects, " J. Clin. Monit. Comput., vol. 26, no. 2, pp. 107-114, 2012.
-
(2012)
J. Clin. Monit. Comput.
, vol.26
, Issue.2
, pp. 107-114
-
-
Wong, J.S.1
Lu, W.A.2
Wu, K.T.3
Liu, M.4
Chen, G.Y.5
Kuo, C.D.6
-
21
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
J. M. Bland and D. G. Altman, "Statistical methods for assessing agreement between two methods of clinical measurement, " Lancet, vol. 1, no. 8476, pp. 307-310, 1986. (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
22
-
-
33847755555
-
Experiment and spectral analysis of a low-power K a-band heartbeat detector measuring from four sides of a human body
-
DOI 10.1109/TMTT.2006.884652
-
C. Li, Y. Xiao, and J. Lin, "Experiment and spectral analysis of a low-power Ka-band heartbeat detector measuring from four sides of a human body, " IEEE Trans. Microw. Theory Tech., vol. 54, no. 12, pp. 4464-4471, Dec. 2006. (Pubitemid 46372455)
-
(2006)
IEEE Transactions on Microwave Theory and Techniques
, vol.54
, Issue.12
, pp. 4464-4471
-
-
Li, C.1
Xiao, Y.2
Lin, J.3
-
23
-
-
84868089892
-
Accurate respiration measurement using DC-coupled continuous-wave Radar sensor for motion-adaptive cancer radiotherapy
-
Nov.
-
C. Gu, R. Li, H. Zhang, A. Y. C. Fung, C. Torres, S. B. Jiang, and C. Li, "Accurate respiration measurement using DC-coupled continuous-wave Radar sensor for motion-adaptive cancer radiotherapy, " IEEE Trans. Biomed. Eng., vol. 59, no. 11, pp. 3117-3123, Nov. 2012.
-
(2012)
IEEE Trans. Biomed. Eng.
, vol.59
, Issue.11
, pp. 3117-3123
-
-
Gu, C.1
Li, R.2
Zhang, H.3
Fung, A.Y.C.4
Torres, C.5
Jiang, S.B.6
Li, C.7
|