-
1
-
-
0037103187
-
American College Of Rheumatology Ad Hoc Committee on immunologic testing guidelines. Evidence-based guidelines for the use of immunologic tests: antinuclear antibody testing
-
10.1002/art.10561, 12209492
-
Solomon DH, Kavanaugh AJ, Schur PH. American College Of Rheumatology Ad Hoc Committee on immunologic testing guidelines. Evidence-based guidelines for the use of immunologic tests: antinuclear antibody testing. Arthritis Rheum 2002, 47:434-444. 10.1002/art.10561, 12209492.
-
(2002)
Arthritis Rheum
, vol.47
, pp. 434-444
-
-
Solomon, D.H.1
Kavanaugh, A.J.2
Schur, P.H.3
-
2
-
-
77955462255
-
ANA screening: an old test with new recommendations
-
10.1136/ard.2009.127100, 20511607
-
Meroni PL, Schur PH. ANA screening: an old test with new recommendations. Ann Rheum Dis 2010, 69:1420-1422. 10.1136/ard.2009.127100, 20511607.
-
(2010)
Ann Rheum Dis
, vol.69
, pp. 1420-1422
-
-
Meroni, P.L.1
Schur, P.H.2
-
3
-
-
77956478503
-
Automated evaluation of autoantibodies on human epithelial-2 cells as an approach to standardize cell-based immunofluorescence tests
-
10.1186/ar2949, 2888187, 20214808
-
Egerer K, Roggenbuck D, Hiemann R, Weyer MG, Büttner T, Radau B, Krause R, Lehmann B, Feist E, Burmester GR. Automated evaluation of autoantibodies on human epithelial-2 cells as an approach to standardize cell-based immunofluorescence tests. Arthritis Res Ther 2010, 12:R40. 10.1186/ar2949, 2888187, 20214808.
-
(2010)
Arthritis Res Ther
, vol.12
-
-
Egerer, K.1
Roggenbuck, D.2
Hiemann, R.3
Weyer, M.G.4
Büttner, T.5
Radau, B.6
Krause, R.7
Lehmann, B.8
Feist, E.9
Burmester, G.R.10
-
4
-
-
84871364636
-
Automated indirect immunofluorescence evaluation of antinuclear autoantibodies on HEp-2 cells
-
3502836, 23251220
-
Voigt J, Krause C, Rohwäder E, Saschenbrecker S, Hahn M, Danckwardt M, Feirer C, Ens K, Fechner K, Barth E, Martinetz T, Stöcker W. Automated indirect immunofluorescence evaluation of antinuclear autoantibodies on HEp-2 cells. Clin Dev Immunol 2012, 2012:651058. 3502836, 23251220.
-
(2012)
Clin Dev Immunol
, vol.2012
, pp. 651058
-
-
Voigt, J.1
Krause, C.2
Rohwäder, E.3
Saschenbrecker, S.4
Hahn, M.5
Danckwardt, M.6
Feirer, C.7
Ens, K.8
Fechner, K.9
Barth, E.10
Martinetz, T.11
Stöcker, W.12
-
5
-
-
84859785377
-
A novel automated indirect immunofluorescence autoantibody evaluation
-
10.1007/s10067-011-1884-1, 22057233
-
Kivity S, Gilburd B, Agmon-Levin N, Carrasco MG, Tzafrir Y, Sofer Y, Mandel M, Buttner T, Roggenbuck D, Matucci-Cerinic M, Danko K, Hoyos ML, Shoenfeld Y. A novel automated indirect immunofluorescence autoantibody evaluation. Clin Rheumatol 2012, 31:503-9. 10.1007/s10067-011-1884-1, 22057233.
-
(2012)
Clin Rheumatol
, vol.31
, pp. 503-509
-
-
Kivity, S.1
Gilburd, B.2
Agmon-Levin, N.3
Carrasco, M.G.4
Tzafrir, Y.5
Sofer, Y.6
Mandel, M.7
Buttner, T.8
Roggenbuck, D.9
Matucci-Cerinic, M.10
Danko, K.11
Hoyos, M.L.12
Shoenfeld, Y.13
-
6
-
-
84862868459
-
A comparative study on the reliability of an automated system for the evaluation of cell-based indirect immunofluorescence
-
10.1016/j.autrev.2011.12.010, 22269861
-
Melegari A, Bonaguri C, Russo A, Luisita B, Trenti T, Lippi G. A comparative study on the reliability of an automated system for the evaluation of cell-based indirect immunofluorescence. Autoimmun Rev 2012, 11:713-716. 10.1016/j.autrev.2011.12.010, 22269861.
-
(2012)
Autoimmun Rev
, vol.11
, pp. 713-716
-
-
Melegari, A.1
Bonaguri, C.2
Russo, A.3
Luisita, B.4
Trenti, T.5
Lippi, G.6
-
7
-
-
84868238761
-
Detection of antinuclear antibodies by automated indirect immunofluorescence analysis
-
Bossuyt X, Cooreman S, De Baere H, Verschueren P, Westhovens R, Blockmans D, Mariën G. Detection of antinuclear antibodies by automated indirect immunofluorescence analysis. Clin Chim Acta 2013, 415:101-6.
-
(2013)
Clin Chim Acta
, vol.415
, pp. 101-106
-
-
Bossuyt, X.1
Cooreman, S.2
De Baere, H.3
Verschueren, P.4
Westhovens, R.5
Blockmans, D.6
Mariën, G.7
-
8
-
-
84896855320
-
Comparison of nova view™ antinuclear antibody titers to manual fluorescent microscopy
-
Abstract n. 300
-
Copple SS, Giles RS, Jaskowski TD, Hill HR. Comparison of nova view™ antinuclear antibody titers to manual fluorescent microscopy. Proceedings of the 8th International Congress on Autoimmunity, Granada (Spain), May 9-13, 2012 Abstract n. 300 http://www.kenes.com/autoimmunity2012/.
-
Proceedings of the 8th International Congress on Autoimmunity, Granada (Spain), May 9-13, 2012
-
-
Copple, S.S.1
Giles, R.S.2
Jaskowski, T.D.3
Hill, H.R.4
-
11
-
-
84896830561
-
Antinuclear antibody (ANA) Screening, titration and pattern recognition: performance of the Zenit G-Sight automatic system
-
Abstract n. 1014
-
Vercammen MJ, De Roeck K, Meirlaen P. Antinuclear antibody (ANA) Screening, titration and pattern recognition: performance of the Zenit G-Sight automatic system. Proceedings of the 8th International Congress on Autoimmunity, Granada (Spain), May 9-13, 2012 Abstract n. 1014 http://www2.kenes.com/autoimmunity2012/Pages/Home.aspx.
-
Proceedings of the 8th International Congress on Autoimmunity, Granada (Spain), May 9-13, 2012
-
-
Vercammen, M.J.1
De Roeck, K.2
Meirlaen, P.3
-
13
-
-
84888117449
-
Automated indirect immunofluorescence antinuclear antibody analysis is a standardized alternative for visual microscope interpretation
-
Bonroy C, Verfaillie C, Smith V, Persijn L, De Witte E, De Keyser F, Devreese K. Automated indirect immunofluorescence antinuclear antibody analysis is a standardized alternative for visual microscope interpretation. Clin Chem Lab Med 2013, 51:1771-9.
-
(2013)
Clin Chem Lab Med
, vol.51
, pp. 1771-1779
-
-
Bonroy, C.1
Verfaillie, C.2
Smith, V.3
Persijn, L.4
De Witte, E.5
De Keyser, F.6
Devreese, K.7
-
14
-
-
84891738740
-
Automated antinuclear immunofluorescence antibody screening: a comparative study of six computer-aided diagnostic systems
-
10.1016/j.autrev.2013.10.015, 24220268, Study Group on Autoimmune Diseases of the Italian Society of Laboratory Medicine, Italy
-
Bizzaro N, Antico A, Platzgummer S, Tonutti E, Bassetti D, Pesente F, Tozzoli R, Tampoia M, Villalta D, Study Group on Autoimmune Diseases of the Italian Society of Laboratory Medicine, Italy Automated antinuclear immunofluorescence antibody screening: a comparative study of six computer-aided diagnostic systems. Autoimmun Rev 2014, 13:292-8. 10.1016/j.autrev.2013.10.015, 24220268, Study Group on Autoimmune Diseases of the Italian Society of Laboratory Medicine, Italy.
-
(2014)
Autoimmun Rev
, vol.13
, pp. 292-298
-
-
Bizzaro, N.1
Antico, A.2
Platzgummer, S.3
Tonutti, E.4
Bassetti, D.5
Pesente, F.6
Tozzoli, R.7
Tampoia, M.8
Villalta, D.9
-
15
-
-
84889651539
-
International recommendations for the assessment of autoantibodies to cellular antigens referred to as anti-nuclear antibodies
-
10.1136/annrheumdis-2013-203863, 24126457
-
Agmon-Levin N, Damoiseaux J, Kallenberg C, Sack U, Witte T, Herold M, Bossuyt X, Musset L, Cervera R, Plaza-Lopez A, Dias C, Sousa MJ, Radice A, Eriksson C, Hultgren O, Viander M, Khamashta M, Regenass S, Andrade LE, Wiik A, Tincani A, Rönnelid J, Bloch DB, Fritzler MJ, Chan EK, Garcia-De La Torre I, Konstantinov KN, Lahita R, Wilson M, Vainio O, et al. International recommendations for the assessment of autoantibodies to cellular antigens referred to as anti-nuclear antibodies. Ann Rheum Dis 2014, 73:17-23. 10.1136/annrheumdis-2013-203863, 24126457.
-
(2014)
Ann Rheum Dis
, vol.73
, pp. 17-23
-
-
Agmon-Levin, N.1
Damoiseaux, J.2
Kallenberg, C.3
Sack, U.4
Witte, T.5
Herold, M.6
Bossuyt, X.7
Musset, L.8
Cervera, R.9
Plaza-Lopez, A.10
Dias, C.11
Sousa, M.J.12
Radice, A.13
Eriksson, C.14
Hultgren, O.15
Viander, M.16
Khamashta, M.17
Regenass, S.18
Andrade, L.E.19
Wiik, A.20
Tincani, A.21
Rönnelid, J.22
Bloch, D.B.23
Fritzler, M.J.24
Chan, E.K.25
Garcia-De La Torre, I.26
Konstantinov, K.N.27
Lahita, R.28
Wilson, M.29
Vainio, O.30
more..
-
17
-
-
50949088213
-
Predictive value of antinuclear autoantibodies: the lessons of the systemic sclerosis autoantibodies
-
10.1016/j.autrev.2008.06.010, 18617021
-
Koenig M, Dieudé M, Senécal JL. Predictive value of antinuclear autoantibodies: the lessons of the systemic sclerosis autoantibodies. Autoimmun Rev 2008, 7:588-593. 10.1016/j.autrev.2008.06.010, 18617021.
-
(2008)
Autoimmun Rev
, vol.7
, pp. 588-593
-
-
Koenig, M.1
Dieudé, M.2
Senécal, J.L.3
-
18
-
-
84875211280
-
The clinical utility of a positive antinuclear antibody test result
-
10.1016/j.amjmed.2012.09.014, 23395534
-
Abeles AM, Abeles M. The clinical utility of a positive antinuclear antibody test result. Am J Med 2013, 126:342-348. 10.1016/j.amjmed.2012.09.014, 23395534.
-
(2013)
Am J Med
, vol.126
, pp. 342-348
-
-
Abeles, A.M.1
Abeles, M.2
-
19
-
-
84884506335
-
Antinuclear antibody test: when to order?
-
Meroni PL, Chan EKL, Tincani A, Garcia de la Torre I, Andrade ELC. Antinuclear antibody test: when to order?. Am J Med 2013, 126:e17.
-
(2013)
Am J Med
, vol.126
-
-
Meroni, P.L.1
Chan, E.K.L.2
Tincani, A.3
Garcia de la Torre, I.4
Andrade, E.L.C.5
|