메뉴 건너뛰기




Volumn 63, Issue 3, 2014, Pages 230-238

Feasibility of left ventricular volume measurements by three-dimensional speckle tracking echocardiography depends on image quality and degree of left ventricular enlargement: Validation study with cardiac magnetic resonance imaging

Author keywords

3 Dimensional echocardiography; Magnetic resonance imaging; Speckle tracking echocardiography; Ventricular function

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CARDIOVASCULAR MAGNETIC RESONANCE; COMPARATIVE STUDY; FEASIBILITY STUDY; FEMALE; HEART EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HEART LEFT VENTRICLE HYPERTROPHY; HEART VENTRICLE ENDDIASTOLIC PRESSURE; HUMAN; IMAGE QUALITY; IMAGING SYSTEM; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; THREE DIMENSIONAL ECHOCARDIOGRAPHY; VALIDATION STUDY; VERY ELDERLY; YOUNG ADULT;

EID: 84896702265     PISSN: 09145087     EISSN: 18764738     Source Type: Journal    
DOI: 10.1016/j.jjcc.2013.08.010     Document Type: Article
Times cited : (22)

References (11)
  • 1
    • 0031925245 scopus 로고    scopus 로고
    • Tissue motion assessment from 3D echographic speckle tracking
    • Meunier J. Tissue motion assessment from 3D echographic speckle tracking. Phys Med Biol 1998, 43:1241-1254.
    • (1998) Phys Med Biol , vol.43 , pp. 1241-1254
    • Meunier, J.1
  • 2
    • 50249143000 scopus 로고    scopus 로고
    • Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: insights from three-dimensional echocardiography and cardiac magnetic resonance imaging
    • Chukwu E.O., Barasch E., Mihalatos D.G., Katz A., Lachmann J., Han J., Reichek N., Gopal A.S. Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: insights from three-dimensional echocardiography and cardiac magnetic resonance imaging. J Am Soc Echocardiogr 2008, 21:990-997.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 990-997
    • Chukwu, E.O.1    Barasch, E.2    Mihalatos, D.G.3    Katz, A.4    Lachmann, J.5    Han, J.6    Reichek, N.7    Gopal, A.S.8
  • 3
    • 0026951140 scopus 로고
    • Ultrasound beam orientation during standard two-dimensional imaging: assessment by three-dimensional echocardiography
    • King D.L., Harrison M.R., King D.L., Gopal A.S., Kwan O.L., DeMaria A.N. Ultrasound beam orientation during standard two-dimensional imaging: assessment by three-dimensional echocardiography. J Am Soc Echocardiogr 1992, 5:569-576.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 569-576
    • King, D.L.1    Harrison, M.R.2    King, D.L.3    Gopal, A.S.4    Kwan, O.L.5    DeMaria, A.N.6
  • 5
    • 84864063779 scopus 로고    scopus 로고
    • Relationship between left ventricular ejection fraction and mitral annular displacement derived by speckle tracking echocardiography in patients with different heart diseases
    • Suzuki K., Akashi Y.J., Mizukoshi K., Kou S., Takai M., Izumo M., Hayashi A., Ohtaki E., Nobuoka S., Miyake F. Relationship between left ventricular ejection fraction and mitral annular displacement derived by speckle tracking echocardiography in patients with different heart diseases. J Cardiol 2012, 60:55-60.
    • (2012) J Cardiol , vol.60 , pp. 55-60
    • Suzuki, K.1    Akashi, Y.J.2    Mizukoshi, K.3    Kou, S.4    Takai, M.5    Izumo, M.6    Hayashi, A.7    Ohtaki, E.8    Nobuoka, S.9    Miyake, F.10
  • 6
    • 33750959891 scopus 로고    scopus 로고
    • Three-dimensional echocardiography: the benefits of the additional dimension
    • Lang R.M., Mor-Avi V., Sugeng L., Nieman P.S., Sahn D.J. Three-dimensional echocardiography: the benefits of the additional dimension. J Am Coll Cardiol 2006, 48:2053-2069.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2053-2069
    • Lang, R.M.1    Mor-Avi, V.2    Sugeng, L.3    Nieman, P.S.4    Sahn, D.J.5
  • 7
    • 4143108001 scopus 로고    scopus 로고
    • Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography
    • Jenkins C., Bricknell K., Hanekom L., Marwick T.H. Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol 2004, 44:878-886.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 878-886
    • Jenkins, C.1    Bricknell, K.2    Hanekom, L.3    Marwick, T.H.4
  • 8
    • 33748090271 scopus 로고    scopus 로고
    • Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters
    • Jenkins C., Chan J., Hanekom L., Marwick T.H. Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters. J Am Soc Echocardiogr 2006, 19:1119-1128.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1119-1128
    • Jenkins, C.1    Chan, J.2    Hanekom, L.3    Marwick, T.H.4
  • 10
    • 67650045051 scopus 로고    scopus 로고
    • Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI
    • Nesser H.J., Mor-Avi V., Gorissen W., Weinert L., Steringer-Mascherbauer R., Niel J. Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI. Eur Heart J 2009, 30:1565-1573.
    • (2009) Eur Heart J , vol.30 , pp. 1565-1573
    • Nesser, H.J.1    Mor-Avi, V.2    Gorissen, W.3    Weinert, L.4    Steringer-Mascherbauer, R.5    Niel, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.