메뉴 건너뛰기




Volumn 58, Issue 22, 2013, Pages 7937-7959

Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: First results in rodents

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD PRESSURE; DISEASE CONTROL; ELECTROCARDIOGRAPHY; ERRORS; FUNCTION EVALUATION; MAMMALS; MATLAB; OPTIMIZATION; PATTERN RECOGNITION; PHYSIOLOGY; POSITRON EMISSION TOMOGRAPHY;

EID: 84896508756     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/58/22/7937     Document Type: Article
Times cited : (13)

References (26)
  • 1
    • 84875334672 scopus 로고    scopus 로고
    • Left ventricular functional assessment in murine models of ischemic and dilated cardiomyopathy using [18F]FDG-PET: Comparison with cardiac MRI and monitoring erythropoietin therapy
    • 10.1186/2191-219X-2-43
    • Brunner S et al 2012 Left ventricular functional assessment in murine models of ischemic and dilated cardiomyopathy using [18F]FDG-PET: comparison with cardiac MRI and monitoring erythropoietin therapy EJNMMI Res. 2 43
    • (2012) EJNMMI Res. , vol.2 , pp. 43
    • Brunner, S.1
  • 2
    • 66149091184 scopus 로고    scopus 로고
    • List mode-driven cardiac and respiratory gating in PET
    • 10.2967/jnumed.108.059204
    • Buther F et al 2009 List mode-driven cardiac and respiratory gating in PET J. Nucl. Med. 50 674-81
    • (2009) J. Nucl. Med. , vol.50 , pp. 674-681
    • Buther, F.1
  • 3
    • 29844438780 scopus 로고    scopus 로고
    • Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: Development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony
    • DOI 10.1016/j.nuclcard.2005.06.088, PII S1071358105004447
    • Chen J et al 2005 Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony J. Nucl. Cardiol. 12 687-95 (Pubitemid 43033609)
    • (2005) Journal of Nuclear Cardiology , vol.12 , Issue.6 , pp. 687-695
    • Chen, J.1    Garcia, E.V.2    Folks, R.D.3    Cooke, C.D.4    Faber, T.L.5    Tauxe, E.L.6    Iskandrian, A.E.7
  • 4
    • 84859406041 scopus 로고    scopus 로고
    • Coronary arterial 18F-FDG uptake by fusion of PET and coronary CT angiography at sites of percutaneous stenting for acute myocardial infarction and stable coronary artery disease
    • 10.2967/jnumed.111.097550
    • Cheng V Y et al 2012 Coronary arterial 18F-FDG uptake by fusion of PET and coronary CT angiography at sites of percutaneous stenting for acute myocardial infarction and stable coronary artery disease J. Nucl. Med. 53 575-83
    • (2012) J. Nucl. Med. , vol.53 , pp. 575-583
    • Cheng, V.Y.1
  • 6
    • 0019773816 scopus 로고
    • Isoflurane: A review
    • 10.1097/00000542-198111000-00014
    • Eger E I 2nd 1981 Isoflurane: a review Anesthesiology 55 559-76
    • (1981) Anesthesiology , vol.55 , pp. 559-576
    • Eger II, E.I.1
  • 8
    • 70350738504 scopus 로고    scopus 로고
    • Reporter gene PET for monitoring survival of transplanted endothelial progenitor cells in the rat heart after pretreatment with VEGF and atorvastatin
    • 10.2967/jnumed.109.067801
    • Higuchi T et al 2009 Reporter gene PET for monitoring survival of transplanted endothelial progenitor cells in the rat heart after pretreatment with VEGF and atorvastatin J. Nucl. Med. 50 1881-6
    • (2009) J. Nucl. Med. , vol.50 , pp. 1881-1886
    • Higuchi, T.1
  • 9
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • 10.1109/42.363108 0278-0062
    • Hudson H M and Larkin R S 1994 Accelerated image reconstruction using ordered subsets of projection data IEEE Trans. Med. Imaging 13 601-9
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 10
    • 0021355079 scopus 로고
    • Baroreceptor reflex control of heart rate during isoflurane anesthesia in humans
    • Kotrly K J et al 1984 Baroreceptor reflex control of heart rate during isoflurane anesthesia in humans Anesthesiology 60 173-9 (Pubitemid 14194807)
    • (1984) Anesthesiology , vol.60 , Issue.3 , pp. 173-179
    • Kotrly, K.J.1    Ebert, T.J.2    Vucins, E.3
  • 13
    • 0028711560 scopus 로고
    • Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
    • 10.1109/42.363099 0278-0062
    • Mumcuoglu E U, Leahy R, Cherry S R and Zhou Z 1994 Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images IEEE Trans. Med. Imaging 13 687-701
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 687-701
    • Mumcuoglu, E.U.1    Leahy, R.2    Cherry, S.R.3    Zhou, Z.4
  • 16
    • 83255187373 scopus 로고    scopus 로고
    • Left ventricular dyssynchrony assessment by phase analysis from gated PET-FDG scans
    • 10.1007/s12350-011-9411-y 1071-3581
    • Pazhenkottil A P et al 2011 Left ventricular dyssynchrony assessment by phase analysis from gated PET-FDG scans J. Nucl. Cardiol. 18 920-5
    • (2011) J. Nucl. Cardiol. , vol.18 , pp. 920-925
    • Pazhenkottil, A.P.1
  • 17
    • 0034178287 scopus 로고    scopus 로고
    • Resolution and noise properties of MAP reconstruction for fully 3-D PET
    • 10.1109/42.870259 0278-0062
    • Qi J and Leahy R M 2000 Resolution and noise properties of MAP reconstruction for fully 3-D PET IEEE Trans. Med. Imaging 19 493-506
    • (2000) IEEE Trans. Med. Imaging , vol.19 , pp. 493-506
    • Qi, J.1    Leahy, R.M.2
  • 18
    • 0031981253 scopus 로고    scopus 로고
    • High-resolution 3D bayesian image reconstruction using the microPET small-animal scanner
    • DOI 10.1088/0031-9155/43/4/027, PII S0031915598906273
    • Qi J, Leahy R M, Cherry S R, Chatziioannou A and Farquhar T H 1998 High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner Phys. Med. Biol. 43 1001-13 (Pubitemid 28168428)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.4 , pp. 1001-1013
    • Qi, J.1    Leahy, R.M.2    Cherry, S.R.3    Chatziioannou, A.4    Farquhar, T.H.5
  • 20
    • 33646439397 scopus 로고    scopus 로고
    • Gated listmode acquisition with the quadHIDAC animal PET to image mouse hearts
    • 0939-3889
    • Schäfers K P, Lang N, Stegger L, Schober O and Schäfers M 2006 Gated listmode acquisition with the quadHIDAC animal PET to image mouse hearts Z. Med. Phys. 16 60-6 PMID: 16696371
    • (2006) Z. Med. Phys. , vol.16 , pp. 60-66
    • Schäfers, K.P.1    Lang, N.2    Stegger, L.3    Schober, O.4    Schäfers, M.5
  • 21
    • 66449092434 scopus 로고    scopus 로고
    • Evaluation of a novel 18F-labeled positron-emission tomography perfusion tracer for the assessment of myocardial infarct size in rats
    • 10.1161/CIRCIMAGING.108.815423
    • Sherif H M et al 2009 Evaluation of a novel 18F-labeled positron-emission tomography perfusion tracer for the assessment of myocardial infarct size in rats Circ. Cardiovasc. Imaging 2 77-84
    • (2009) Circ. Cardiovasc. Imaging , vol.2 , pp. 77-84
    • Sherif, H.M.1
  • 22
    • 58249114882 scopus 로고    scopus 로고
    • Quantification of left ventricular volumes and ejection fraction in mice using PET, compared with MRI
    • 10.2967/jnumed.108.056051
    • Stegger L et al 2009 Quantification of left ventricular volumes and ejection fraction in mice using PET, compared with MRI J. Nucl. Med. 50 132-8
    • (2009) J. Nucl. Med. , vol.50 , pp. 132-138
    • Stegger, L.1
  • 23
    • 79851485624 scopus 로고    scopus 로고
    • Electrocardiogram-gated 18F-FDG PET/CT hybrid imaging in patients with unsatisfactory response to cardiac resynchronization therapy: Initial clinical results
    • 10.2967/jnumed.110.078709
    • Uebleis C et al 2011 Electrocardiogram-gated 18F-FDG PET/CT hybrid imaging in patients with unsatisfactory response to cardiac resynchronization therapy: initial clinical results J. Nucl. Med. 52 67-71
    • (2011) J. Nucl. Med. , vol.52 , pp. 67-71
    • Uebleis, C.1
  • 24
    • 21344433041 scopus 로고    scopus 로고
    • Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating
    • DOI 10.1088/0031-9155/50/13/001
    • Yang Y, Rendig S, Siegel S, Newport D F and Cherry S R 2005 Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating Phys. Med. Biol. 50 2979-89 (Pubitemid 40905180)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.13 , pp. 2979-2989
    • Yang, Y.1    Rendig, S.2    Siegel, S.3    Newport, D.F.4    Cherry, S.R.5
  • 26
    • 84875786583 scopus 로고    scopus 로고
    • Quantitative PET imaging detects early metabolic remodeling in a mouse model of pressure-overload left ventricular hypertrophy in vivo
    • 10.2967/jnumed.112.108092
    • Zhong M, Alonso C E, Taegtmeyer H and Kundu B K 2013 Quantitative PET imaging detects early metabolic remodeling in a mouse model of pressure-overload left ventricular hypertrophy in vivo J. Nucl. Med. 54 609-15
    • (2013) J. Nucl. Med. , vol.54 , pp. 609-615
    • Zhong, M.1    Alonso, C.E.2    Taegtmeyer, H.3    Kundu, B.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.