Volumn 60, Issue 3, 2014, Pages 369-376

Analytical Performance of the Axis-Shield Afinion® for Hemoglobin A1c Measurement: Impact of Lot Number

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; HEMOGLOBIN A; HEMOGLOBIN A1C; HEMOGLOBIN F; HEMOGLOBIN S;

EID: 84896449108     PISSN: 14336510     EISSN: None     Source Type: Journal    
DOI: 10.7754/Clin.Lab.2013.130209     Document Type: Article
Times cited : (3)

References (19)
  • 1
    • 73449098203 scopus 로고    scopus 로고
    • Six of eight hemoglobin A1c point-of-care instruments do not meet the general accepted analytical performance criteria
    • Lenters-Westra E, Slingerland RJ. Six of eight hemoglobin A1c point-of-care instruments do not meet the general accepted analytical performance criteria. Clin Chem 2010;56(1):44-52.
    • (2010) Clin Chem , vol.56 , Issue.1 , pp. 44-52
    • Lenters-Westra, E.1    Slingerland, R.J.2
  • 2
    • 80052204168 scopus 로고    scopus 로고
    • Point-of-care assays for hemoglobin A(1c): Is performance adequate?
    • Sep
    • Little RR, Lenters-Westra E, Rohlfing CL, Slingerland R. Point-of-care assays for hemoglobin A(1c): is performance adequate? Clin Chem 2011 Sep;57(9):1333-4.
    • (2011) Clin Chem , vol.57 , Issue.9 , pp. 1333-1334
    • Little, R.R.1    Lenters-Westra, E.2    Rohlfing, C.L.3    Slingerland, R.4
  • 3
    • 84865127683 scopus 로고    scopus 로고
    • Accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device
    • Mar 1
    • Wood JR, Kaminski BM, Kollman C, et al. Accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device. J Diabetes Sci Technol 2012 Mar 1;6(2):380-6.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.2 , pp. 380-386
    • Wood, J.R.1    Kaminski, B.M.2    Kollman, C.3
  • 4
    • 77950511412 scopus 로고    scopus 로고
    • Executive Summary: Standards of Medical Care in Diabetes - 2010. American Diabetes Association.
    • Executive Summary: Standards of Medical Care in Diabetes - 2010. American Diabetes Association. Diabetes Care 2010;33:S4-S10.
    • (2010) Diabetes Care , vol.33
  • 5
    • 79957759364 scopus 로고    scopus 로고
    • Executive summary: Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks DB, Arnold M, Bakris GL, et al. Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2011;57:793-8.
    • (2011) Clin Chem , vol.57 , pp. 793-798
    • Sacks, D.B.1    Arnold, M.2    Bakris, G.L.3
  • 6
    • 48149095259 scopus 로고    scopus 로고
    • A1c-Derived Average Glucose Study Group. Translating the A1C assay into estimated average glucose values
    • Nathan DM, Kuenen J, Borg R, Zheng H, Schoenfeld D, Heine RJ. A1c-Derived Average Glucose Study Group. Translating the A1C assay into estimated average glucose values. Diabetes Care 2008;31(18):1473-8.
    • (2008) Diabetes Care , vol.31 , Issue.18 , pp. 1473-1478
    • Nathan, D.M.1    Kuenen, J.2    Borg, R.3    Zheng, H.4    Schoenfeld, D.5    Heine, R.J.6
  • 7
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:13.
    • (1999) Stat Methods Med Res , vol.8 , pp. 13
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 84896464835 scopus 로고    scopus 로고
    • updated 03/10
    • NGSP News (updated 03/10) (http://www.ngsp.org/).
  • 9
    • 0030198136 scopus 로고    scopus 로고
    • The meaning of kappa: Probabilistic concepts of reliability and validity revisited
    • DOI 10.1016/0895-4356(96)00011-X
    • Guggenmoos-Holzmann I. The meaning of kappa: probabilistic concepts of reliability and validity revisited. J Clin Epidemiol 1996;49:775-82. (Pubitemid 26280729)
    • (1996) Journal of Clinical Epidemiology , vol.49 , Issue.7 , pp. 775-782
    • Guggenmoos-Holzmann, I.1
  • 10
    • 0030021476 scopus 로고    scopus 로고
    • Analysis of method comparison studies
    • Hollis S. Analysis of method comparison studies. Ann Clin Biochem 1996;33 (Pt. 1):1.
    • (1996) Ann Clin Biochem , vol.33 , Issue.PART 1 , pp. 1
    • Hollis, S.1
  • 12
    • 77957749916 scopus 로고    scopus 로고
    • Hemoglobin A1c: Assessment of three POC analyzers relative to a central laboratory method
    • Petersen JR, Omoruyi FO, Mohammad AA, Shea TJ, Okorodudu AO, Ju H. Hemoglobin A1c: assessment of three POC analyzers relative to a central laboratory method. Clin Chim Acta 2010;411(23-24):2062-6.
    • (2010) Clin Chim Acta , vol.411 , Issue.23-24 , pp. 2062-2066
    • Petersen, J.R.1    Omoruyi, F.O.2    Mohammad, A.A.3    Shea, T.J.4    Okorodudu, A.O.5    Ju, H.6
  • 13
    • 84865108207 scopus 로고    scopus 로고
    • Analysis of the accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device
    • Mar 1
    • Little RR. Analysis of the accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device. J Diabetes Sci Technol 2012 Mar 1;6(2):387-8.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.2 , pp. 387-388
    • Little, R.R.1
  • 15
    • 1542328914 scopus 로고    scopus 로고
    • 1c measured by DCA 2000 and by HPLC: Effects of fetal hemoglobin concentrations
    • DOI 10.1016/j.arcmed.2003.10.003, PII S0188440903001541
    • Diem P, Wälchli M, Mullis PE, Marti U. Agreement between HbA1c measured by DCA 2000 and by HPLC: effects of fetal hemoglobin concentrations. Arch Med Res 2004;35(2):145-9. (Pubitemid 38316834)
    • (2004) Archives of Medical Research , vol.35 , Issue.2 , pp. 145-149
    • Diem, P.1    Walchli, M.2    Mullis, P.E.3    Marti, U.4
  • 16
    • 44849133588 scopus 로고    scopus 로고
    • The Effect of Elevated Fetal Hemoglobin on Hemoglobin A1c Results. Five Common Hemoglobin A1c Methods Compared With the IFCC Reference Method
    • Rohlfing CL, Connolly SM, England JD, et al. The Effect of Elevated Fetal Hemoglobin on Hemoglobin A1c Results. Five Common Hemoglobin A1c Methods Compared With the IFCC Reference Method. Am J Clin Pathol 2008;129(5):811-4.
    • (2008) Am J Clin Pathol , vol.129 , Issue.5 , pp. 811-814
    • Rohlfing, C.L.1    Connolly, S.M.2    England, J.D.3
  • 17
    • 0030947659 scopus 로고    scopus 로고
    • Evaluation of the Menarini-Arkray HA 8140 hemoglobin A(1c) analyzer
    • John WG, Braconnier F, Miedema K, Aulesa C, Piras G. Evaluation of the Menarini-Arkray HA 8140 hemoglobin A1c analyzer. Clin Chem 1997;43(6 Pt 1):968-75. (Pubitemid 27246987)
    • (1997) Clinical Chemistry , vol.43 , Issue.6 , pp. 968-975
    • John, W.G.1    Braconnier, F.2    Miedema, K.3    Aulesa, C.4    Piras, G.5
  • 19
    • 77955877141 scopus 로고    scopus 로고
    • A review of variant hemoglobins interfering with hemoglobin A1c measurement
    • May 1
    • Little RR, Roberts WL. A review of variant hemoglobins interfering with hemoglobin A1c measurement. J Diabetes Sci Technol. 2009 May 1;3(3):446-51.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.3 , pp. 446-451
    • Little, R.R.1    Roberts, W.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.