메뉴 건너뛰기




Volumn 15, Issue 2, 2014, Pages 116-122

CircuLite Synergy ventricular assist device: A new approach to end-stage congestive heart failure;Sistema di assistenza ventricolare CircuLite Synergy: un nuovo approccio all'insufficienza cardiaca terminale

Author keywords

Elderly; Heart failure; Hemodynamics; Left ventricular assist device

Indexed keywords

AGED; ARTICLE; ASSISTED CIRCULATION; BLEEDING; BODY SIZE; CONTROLLED STUDY; FOLLOW UP; HEART DISEASE; HEART FAILURE; HEART LEFT ATRIUM; HEMODYNAMICS; HUMAN; KIDNEY FAILURE; LEFT VENTRICULAR ASSIST DEVICE; MAJOR CLINICAL STUDY; MINNESOTA LIVING WITH HEART FAILURE QUESTIONNAIRE; NAMED INVENTORIES, QUESTIONNAIRES AND RATING SCALES; PUMP; SUBCLAVIAN ARTERY;

EID: 84896372253     PISSN: 18276806     EISSN: 19726481     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (10)
  • 1
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure
    • Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 2001;345:1435-43.
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 2
    • 58249094014 scopus 로고    scopus 로고
    • Partial left ventricular support implanted through minimal access surgery as a bridge to cardiac transplant
    • Meyns B, Rega F, Ector J, et al. Partial left ventricular support implanted through minimal access surgery as a bridge to cardiac transplant. J Thorac Cardiovasc Surg 2009; 137:243-5.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 243-245
    • Meyns, B.1    Rega, F.2    Ector, J.3
  • 3
    • 67449085092 scopus 로고    scopus 로고
    • Proof of concept: Hemodynamic response to long-term partial ventricular support with the synergy pocket micro-pump
    • Meyns B, Klotz S, Simon A, et al. Proof of concept: hemodynamic response to long-term partial ventricular support with the synergy pocket micro-pump. J Am Coll Cardiol 2009;54:79-86.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 79-86
    • Meyns, B.1    Klotz, S.2    Simon, A.3
  • 4
    • 54149090060 scopus 로고    scopus 로고
    • First human use of partial left ventricular heart support with the Circulite synergy micro-pump as a bridge to cardiac transplantation
    • Meyns B, Ector J, Rega F, et al. First human use of partial left ventricular heart support with the Circulite synergy micro-pump as a bridge to cardiac transplantation. Eur Heart J 2008;29:2582.
    • (2008) Eur Heart J , vol.29 , pp. 2582
    • Meyns, B.1    Ector, J.2    Rega, F.3
  • 5
    • 0026699989 scopus 로고
    • Assessment of patient outcome with the Minnesota Living with Heart Failure questionnaire: Reliability and validity during a randomized, doubleblind, placebo-controlled trial of pimobendan. Pimobendan Multicenter Research Group
    • Rector TS, Cohn JN. Assessment of patient outcome with the Minnesota Living with Heart Failure questionnaire: reliability and validity during a randomized, doubleblind, placebo-controlled trial of pimobendan. Pimobendan Multicenter Research Group. Am Heart J 1992;124: 1017-25.
    • (1992) Am Heart J , vol.124 , pp. 1017-1025
    • Rector, T.S.1    Cohn, J.N.2
  • 6
    • 34548311569 scopus 로고    scopus 로고
    • Use of a continuous-flow device in patients awaiting heart transplantation
    • Miller LW, Pagani FD, Russell SD, et al. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 2007;357:885-96.
    • (2007) N Engl J Med , vol.357 , pp. 885-896
    • Miller, L.W.1    Pagani, F.D.2    Russell, S.D.3
  • 7
    • 74249110561 scopus 로고    scopus 로고
    • European results with a continuous-flow ventricular assist device for advanced heart-failure patients
    • Lahpor J, Khaghani A, Hetzer R, et al. European results with a continuous-flow ventricular assist device for advanced heart-failure patients. Eur J Cardiothorac Surg 2010; 37:357-61.
    • (2010) Eur J Cardiothorac Surg , vol.37 , pp. 357-361
    • Lahpor, J.1    Khaghani, A.2    Hetzer, R.3
  • 8
    • 79954589537 scopus 로고    scopus 로고
    • Clinical benefits of partial circulatory support in New York Heart Association Class IIIB and Early Class IV patients
    • Meyns BP, Simon A, Klotz S, et al. Clinical benefits of partial circulatory support in New York Heart Association Class IIIB and Early Class IV patients. Eur J Cardiothorac Surg 2011;39:693-8.
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 693-698
    • Meyns, B.P.1    Simon, A.2    Klotz, S.3
  • 9
    • 33845803269 scopus 로고    scopus 로고
    • Hemodynamic effects of partial ventricular support in chronic heart failure: Results of simulation validated with in vivo data
    • Morley D, Litwak K, Ferber P, et al. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data. J Thorac Cardiovasc Surg 2007;133:21-8.
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 21-28
    • Morley, D.1    Litwak, K.2    Ferber, P.3
  • 10
    • 84880648533 scopus 로고    scopus 로고
    • Circulatory support in elderly chronic heart failure patients using the CircuLite Synergy system
    • Barbone A, Pini D, Rega F, Ornaghi D, Vitali E, Meyns B. Circulatory support in elderly chronic heart failure patients using the CircuLite Synergy system. Eur J Cardiothorac Surg 2013;44:207-12.
    • (2013) Eur J Cardiothorac Surg , vol.44 , pp. 207-212
    • Barbone, A.1    Pini, D.2    Rega, F.3    Ornaghi, D.4    Vitali, E.5    Meyns, B.6