Volumn 59, Issue 3, 2014, Pages 406-410

Apnea testing: The effects of insufflation catheter size and flow on pressure and volume in a test lung

Author keywords

Apnea test; Brain death

Indexed keywords

APNEA; ARTICLE; ENDOTRACHEAL TUBE; HUMAN; INSUFFLATION CATHETER; LUNG FUNCTION; LUNG FUNCTION TEST; LUNG PRESSURE; LUNG VENTILATION; OUTCOME ASSESSMENT; OXYGEN SUPPLY; RESPIRATORY THERAPEUTIC DEVICE; RESPIRATORY TRACT INTUBATION; RISK ASSESSMENT; AERATION; AUDIOVISUAL EQUIPMENT; BRAIN DEATH; CATHETER; DEVICES; DIAGNOSIS; ENDOTRACHEAL INTUBATION; EQUIPMENT DESIGN; LUNG COMPLIANCE; LUNG VOLUME; MULTIVARIATE ANALYSIS; PRESSURE;

EID: 84895485783     PISSN: 00201324     EISSN: 19433654     Source Type: Journal    
DOI: 10.4187/respcare.02499     Document Type: Article
Times cited : (11)

References (14)
  • 1
    • 77953331308 scopus 로고    scopus 로고
    • Evidencebased guideline update: Determining brain death in adults
    • DOI: 10.1212/WNL.0b013e3181e242a8
    • Wijdicks, EFM, Varelas PN, Gronseth GS, Greer DM. Evidencebased guideline update: determining brain death in adults. Neurology 2010;74(23):1911-1918. DOI: 10.1212/WNL.0b013e3181e242a8.
    • (2010) Neurology , vol.74 , Issue.23 , pp. 1911-1918
    • Wijdicks, E.F.M.1    Varelas, P.N.2    Gronseth, G.S.3    Greer, D.M.4
  • 2
    • 0029058935 scopus 로고
    • Report of the quality standards subcommittee of the American Academy of Neurology. Practice parameters for determining brain death in adults: Summary statement
    • Report of the quality standards subcommittee of the American Academy of Neurology. Practice parameters for determining brain death in adults: summary statement. Neurology 1995;45(5):1012-1014.
    • (1995) Neurology , vol.45 , Issue.5 , pp. 1012-1014
  • 3
    • 0034276660 scopus 로고    scopus 로고
    • Pneumothorax and pneumoperitoneum during the apnea test: How safe is this procedure?
    • Saposnik G, Rizzo G, Deluca JL. Pneumothorax and pneumoperitoneum during the apnea test: how safe is this procedure? Arq Neuropisquiatr 2000;58(3-B):905-908.
    • (2000) Arq Neuropisquiatr , vol.58 , Issue.3 B , pp. 905-908
    • Saposnik, G.1    Rizzo, G.2    Deluca, J.L.3
  • 4
    • 7244223332 scopus 로고    scopus 로고
    • Problems associated with the apnea test in the diagnosis of brain death
    • Saposnik G, Rizzo G, Vega A, Sabbatiello R, Deluca JL. Problems associated with the apnea test in the diagnosis of brain death. Neurol India 2004;52(3):342-345.
    • (2004) Neurol India , vol.52 , Issue.3 , pp. 342-345
    • Saposnik, G.1    Rizzo, G.2    Vega, A.3    Sabbatiello, R.4    Deluca, J.L.5
  • 5
    • 50549100793 scopus 로고    scopus 로고
    • Complications associated with the apnea test in the determination of brain death
    • Xiao-liang WU, Qiang FANG, Li Li, Yun-qing QIU, Ben-yan LUO. Complications associated with the apnea test in the determination of brain death. Chin Med J 2008;121(13):1169-1172.
    • (2008) Chin Med J , vol.121 , Issue.13 , pp. 1169-1172
    • Xiao-liang, W.U.1    Qiang, F.A.N.G.2    Li, L.3    Yun-qing, Q.I.U.4    Ben-yan, L.U.O.5
  • 6
    • 70350118706 scopus 로고    scopus 로고
    • Brain death diagnosis and apnea test safety
    • DOI: 10.4103/0972-2327.56326
    • Machado C, Perez J, Scherle C, Areu A, Pando A. Brain death diagnosis and apnea test safety. Ann Indian Acad Neurol 2009;12(3): 197-200. DOI: 10.4103/0972-2327.56326.
    • (2009) Ann Indian Acad Neurol , vol.12 , Issue.3 , pp. 197-200
    • McHado, C.1    Perez, J.2    Scherle, C.3    Areu, A.4    Pando, A.5
  • 7
    • 41549087332 scopus 로고    scopus 로고
    • Tension Pneumothorax complicating apnea testing during brain death evaluation
    • DOI: 10.1016/j.jocn.2007.02.009
    • Burns JD, Russell JA. Tension Pneumothorax complicating apnea testing during brain death evaluation. J Clin Neurosci 2008;15(5): 580-582. DOI: 10.1016/j.jocn.2007.02.009.
    • (2008) J Clin Neurosci , vol.15 , Issue.5 , pp. 580-582
    • Burns, J.D.1    Russell, J.A.2
  • 8
    • 44449109995 scopus 로고    scopus 로고
    • Barotrauma during apnoea testing for brain death determination in a five-year-old boy
    • Monterrubio-Villar J, Cordabo-Lopez A. Barotrauma during apnoea testing for brain death determination in a five-year-old boy. Anesth Intensive Care 2008;36(3):462-463.
    • (2008) Anesth Intensive Care , vol.36 , Issue.3 , pp. 462-463
    • Monterrubio-Villar, J.1    Cordabo-Lopez, A.2
  • 9
    • 28144449343 scopus 로고    scopus 로고
    • Apnea testing for the diagnosis of brain death
    • Lang CJG, Heckmann JG. Apnea testing for the diagnosis of brain death. Acta Neurol Scand 2005;112(6):358-369.
    • (2005) Acta Neurol Scand , vol.112 , Issue.6 , pp. 358-369
    • Lang, C.J.G.1    Heckmann, J.G.2
  • 10
    • 0031739103 scopus 로고    scopus 로고
    • Tension pneumothorax during apnea testing for the determination of brain death
    • Bar-Joseph G, Bar-Lavie Y, Zonis Z. Tension pneumothorax during apnea testing for the determination of brain death. Anesthesiology 1998;89(5):1250-1251.
    • (1998) Anesthesiology , vol.89 , Issue.5 , pp. 1250-1251
    • Bar-Joseph, G.1    Bar-Lavie, Y.2    Zonis, Z.3
  • 11
    • 77956632642 scopus 로고    scopus 로고
    • AARC clinical practice guideline: Endotracheal suctioning of mechanically ventilated patients with artificial airways 2010
    • Restrepo R, Brown J, Hughes J. AARC clinical practice guideline: endotracheal suctioning of mechanically ventilated patients with artificial airways 2010. Respir Care 2010;55(6):758-764.
    • (2010) Respir Care , vol.55 , Issue.6 , pp. 758-764
    • Restrepo, R.1    Brown, J.2    Hughes, J.3
  • 12
    • 0002657951 scopus 로고
    • The effects of negative pressure during tracheal suction
    • Rossen M, Hillard E. The effects of negative pressure during tracheal suction. Anesth Analg 1962;41(1):50-57.
    • (1962) Anesth Analg , vol.41 , Issue.1 , pp. 50-57
    • Rossen, M.1    Hillard, E.2
  • 13
    • 0024991195 scopus 로고
    • The effects of variations in flow through an insufflating catheter and endotracheal-tube and suction-catheter on test-lung pressures
    • Tiffin NH, Keim MR, Frewen TC. The effects of variations in flow through an insufflating catheter and endotracheal-tube and suction-catheter on test-lung pressures. Respir Care 1990;35(9):889-897.
    • (1990) Respir Care , vol.35 , Issue.9 , pp. 889-897
    • Tiffin, N.H.1    Keim, M.R.2    Frewen, T.C.3
  • 14
    • 33847016457 scopus 로고    scopus 로고
    • The safe limits of mechanical factors in the apnea testing for the diagnosis of brain death
    • Olguner C, Koca U, Akan M, Karci A, Elar Z. The safe limits of mechanical factors in the apnea testing for the diagnosis of brain death. Tohoku J Exp Med 2007;211(2):115-120.
    • (2007) Tohoku J Exp Med , vol.211 , Issue.2 , pp. 115-120
    • Olguner, C.1    Koca, U.2    Akan, M.3    Karci, A.4    Elar, Z.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.