메뉴 건너뛰기




Volumn 28, Issue 1, 2014, Pages 83-93

USCOM - Window to the circulation: Utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy

Author keywords

Cardiac output; Doppler; Robotic surgery; Supra sternal

Indexed keywords

AGED, 80 AND OVER; ANESTHESIA; CARDIAC OUTPUT; CYSTECTOMY; ECHOCARDIOGRAPHY, DOPPLER; EQUIPMENT DESIGN; ESOPHAGUS; HEMODYNAMICS; HUMANS; MALE; MONITORING, INTRAOPERATIVE; MONITORING, PHYSIOLOGIC; ROBOTICS; SURGERY, COMPUTER-ASSISTED; TOMOGRAPHY, X-RAY COMPUTED; URINARY BLADDER NEOPLASMS; UROLOGIC SURGICAL PROCEDURES;

EID: 84895074457     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-013-9499-5     Document Type: Article
Times cited : (13)

References (26)
  • 2
    • 84872137892 scopus 로고    scopus 로고
    • Noninvasive cardiac output monitors: A state-of the-art review
    • 22609340 10.1053/j.jvca.2012.03.022
    • Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth. 2013;27:121-34.
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. 121-134
    • Marik, P.E.1
  • 3
    • 84867205980 scopus 로고    scopus 로고
    • A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM)
    • 1:STN:280:DC%2BC38bhvFerug%3D%3D 22928650 10.1111/j.1365-2044.2012.07311. x
    • Chong SW, Peyton PJ. A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM). Anaesthesia. 2012;67:1266-71.
    • (2012) Anaesthesia , vol.67 , pp. 1266-1271
    • Chong, S.W.1    Peyton, P.J.2
  • 4
    • 79958110885 scopus 로고    scopus 로고
    • A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
    • 20966436 10.1213/ANE.0b013e3181eeaae5
    • Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg. 2011;112:1392-402.
    • (2011) Anesth Analg , vol.112 , pp. 1392-1402
    • Hamilton, M.A.1    Cecconi, M.2    Rhodes, A.3
  • 5
    • 14544292461 scopus 로고    scopus 로고
    • Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs
    • 15728064 10.1213/01.ANE.0000144774.42408.05
    • Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA. Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg. 2005;100:748-53.
    • (2005) Anesth Analg , vol.100 , pp. 748-753
    • Critchley, L.A.1    Peng, Z.Y.2    Fok, B.S.3    Lee, A.4    Phillips, R.A.5
  • 6
    • 84895076530 scopus 로고    scopus 로고
    • USCOM USCOM Ltd. Sydney
    • USCOM. USCOM users manual. Sydney: USCOM Ltd.; 2012.
    • (2012) USCOM Users Manual
  • 7
    • 22644432668 scopus 로고    scopus 로고
    • Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor
    • 15953218 10.1111/j.1742-6723.2005.00722.x
    • Dey I, Sprivulis P. Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor. Emerg Med Australas. 2005;17:193-9.
    • (2005) Emerg Med Australas , vol.17 , pp. 193-199
    • Dey, I.1    Sprivulis, P.2
  • 8
    • 0001127258 scopus 로고
    • An analysis of the time-relations of electrocardiograms
    • Bazett HC. An analysis of the time-relations of electrocardiograms. Heart. 1920;7:353-70.
    • (1920) Heart , vol.7 , pp. 353-370
    • Bazett, H.C.1
  • 9
    • 84888237002 scopus 로고    scopus 로고
    • Non-invasive method for rapid bedside estimation of inotropy: Theory and preliminary clinical validation
    • (Epub) Aug 1
    • Smith BE, Madigan VM. Non-invasive method for rapid bedside estimation of inotropy: theory and preliminary clinical validation. Br J Anaesth. (Epub) Aug 1, 2013.
    • (2013) Br J Anaesth.
    • Smith, B.E.1    Madigan, V.M.2
  • 10
    • 84876126987 scopus 로고    scopus 로고
    • Measurement of systemic oxygen delivery and inotropy in healthy term neonates with the ultrasonic cardiac output monitor (USCOM)
    • He SR, Sun X, Zhang C, Jian Z, Sun YX, Zheng ML, Liu YM, Madigan VM, Smith BE. Measurement of systemic oxygen delivery and inotropy in healthy term neonates with the ultrasonic cardiac output monitor (USCOM). Early Hum Dev. 2013;89:289-94.
    • (2013) Early Hum Dev. , vol.89 , pp. 289-294
    • He, S.R.1    Sun, X.2    Zhang, C.3    Jian, Z.4    Sun, Y.X.5    Zheng, M.L.6    Liu, Y.M.7    Madigan, V.M.8    Smith, B.E.9
  • 11
    • 0026506397 scopus 로고
    • New perspectives in the assessment of cardiac chamber dimensions during development and adulthood
    • 1:STN:280:DyaK383gt1Gqsg%3D%3D 1552123 10.1016/0735-1097(92)90282-R
    • Nidorf SM, Picard MH, Triulzi MO, Thomas JD, Newell J, King ME, Weyman AE. New perspectives in the assessment of cardiac chamber dimensions during development and adulthood. J Am Coll Cardiol. 1992;19:983-8.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 983-988
    • Nidorf, S.M.1    Picard, M.H.2    Triulzi, M.O.3    Thomas, J.D.4    Newell, J.5    King, M.E.6    Weyman, A.E.7
  • 12
    • 0345117136 scopus 로고    scopus 로고
    • Esophageal Doppler: Noninvasive cardiac output monitor
    • 14641384 10.1111/j.0742-2822.2003.03033.x
    • Cholley BP, Singer M. Esophageal Doppler: noninvasive cardiac output monitor. Echocardiography. 2003;20:763-9.
    • (2003) Echocardiography , vol.20 , pp. 763-769
    • Cholley, B.P.1    Singer, M.2
  • 13
    • 84895076446 scopus 로고    scopus 로고
    • Differences between Cardio-Q and USCOM Doppler cardiac output readings in high risk surgery patients
    • (Abstract)
    • Critchley LA. Differences between Cardio-Q and USCOM Doppler cardiac output readings in high risk surgery patients. Br J Anaesth. 2012;108(Suppl 2):113-114 (Abstract).
    • (2012) Br J Anaesth. , vol.108 , Issue.SUPPL. 2 , pp. 113-114
    • Critchley, L.A.1
  • 14
    • 84895074507 scopus 로고    scopus 로고
    • Comparison of USCOM and CardioQ Doppler cardiac output in high risk surgery
    • (Abstract)(in press)
    • Huang L, Critchley LA. Comparison of USCOM and CardioQ Doppler cardiac output in high risk surgery. Anaesth Intens Care. 2013;41:(Abstract)(in press).
    • (2013) Anaesth Intens Care , vol.41
    • Huang, L.1    Critchley, L.A.2
  • 16
    • 0029129358 scopus 로고
    • The extraperitoneal approach and subcutaneous emphysema are associated with greater absorption of carbon dioxide during laparoscopic renal surgery
    • 7637101 10.1016/S0022-5347(01)66943-X
    • Wolf JS Jr, Monk TG, McDougall EM, McClennan BL, Clayman RV. The extraperitoneal approach and subcutaneous emphysema are associated with greater absorption of carbon dioxide during laparoscopic renal surgery. J Urol. 1995;154:959-63.
    • (1995) J Urol , vol.154 , pp. 959-963
    • Wolf, Jr.J.S.1    Monk, T.G.2    McDougall, E.M.3    McClennan, B.L.4    Clayman, R.V.5
  • 17
    • 78650503486 scopus 로고    scopus 로고
    • Surgical emphysema as a cause of severe hypercapnia during laparoscopic surgery
    • 1:STN:280:DC%2BC3M7gvVyrtA%3D%3D 21226444
    • Critchley LA, Ho AM. Surgical emphysema as a cause of severe hypercapnia during laparoscopic surgery. Anaesth Intensive Care. 2010;38:1094-100.
    • (2010) Anaesth Intensive Care , vol.38 , pp. 1094-1100
    • Critchley, L.A.1    Ho, A.M.2
  • 19
    • 78149469431 scopus 로고    scopus 로고
    • A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output
    • 20736431 10.1213/ANE.0b013e3181f08a5b
    • Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180-92.
    • (2010) Anesth Analg , vol.111 , pp. 1180-1192
    • Critchley, L.A.1    Lee, A.2    Ho, A.M.3
  • 20
    • 0025833943 scopus 로고
    • Transesophageal Doppler cardiac output monitoring: Performance during aortic reconstructive surgery
    • 1952170 10.1213/00000539-199112000-00006
    • Perrino AC Jr, Fleming J, LaMantia KR. Transesophageal Doppler cardiac output monitoring: performance during aortic reconstructive surgery. Anesth Analg. 1991;73:705-10.
    • (1991) Anesth Analg , vol.73 , pp. 705-710
    • Perrino, Jr.A.C.1    Fleming, J.2    Lamantia, K.R.3
  • 21
    • 84866258808 scopus 로고    scopus 로고
    • Pulmonary artery catheter (PAC) accuracy and efficacy compared with flow probe and transcutaneous Doppler (USCOM): An ovine cardiac output validation
    • ID:621496
    • Phillips RA, Hood SG, Jacobson BM, West MJ, Wan L, May CN. Pulmonary artery catheter (PAC) accuracy and efficacy compared with flow probe and transcutaneous Doppler (USCOM): an ovine cardiac output validation. Crit Care Res Pract. 2012;ID:621496.
    • (2012) Crit Care Res Pract.
    • Phillips, R.A.1    Hood, S.G.2    Jacobson, B.M.3    West, M.J.4    Wan, L.5    May, C.N.6
  • 22
    • 84885955122 scopus 로고    scopus 로고
    • A study to determine the reliability of supra-sternal Doppler (USCOM) during general anaesthesia: Effects of scan quality, flow volume and increasing age
    • (Epub) Jul 23
    • Huang L, Critchley LA. A study to determine the reliability of supra-sternal Doppler (USCOM) during general anaesthesia: effects of scan quality, flow volume and increasing age. Br J Anaesth. (Epub) Jul 23, 2013.
    • (2013) Br J Anaesth
    • Huang, L.1    Critchley, L.A.2
  • 23
    • 84860281521 scopus 로고    scopus 로고
    • Anesthetic concerns for robotic-assisted laparoscopic radical prostatectomy
    • 1:STN:280:DC%2BC38vms1KnsQ%3D%3D 22415437
    • Gainsburg DM. Anesthetic concerns for robotic-assisted laparoscopic radical prostatectomy. Minerva Anestesiol. 2012;78:596-604.
    • (2012) Minerva Anestesiol , vol.78 , pp. 596-604
    • Gainsburg, D.M.1
  • 24
    • 68049142922 scopus 로고    scopus 로고
    • Oesophageal Doppler
    • 19417642 10.1097/MCC.0b013e32832b7083
    • Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009;15:244-8.
    • (2009) Curr Opin Crit Care , vol.15 , pp. 244-248
    • Singer, M.1
  • 25
    • 84869413360 scopus 로고    scopus 로고
    • Haemodynamic effects from aortocaval compression at different angles of lateral tilt in non-labouring term pregnant women
    • 1:STN:280:DC%2BC3s%2Fks1Sjsg%3D%3D 23059960 10.1093/bja/aes349
    • Lee SW, Khaw KS, Ngan Kee WD, Leung TY, Critchley LA. Haemodynamic effects from aortocaval compression at different angles of lateral tilt in non-labouring term pregnant women. Br J Anaesth. 2012;109:950-6.
    • (2012) Br J Anaesth , vol.109 , pp. 950-956
    • Lee, S.W.1    Khaw, K.S.2    Ngan Kee, W.D.3    Leung, T.Y.4    Critchley, L.A.5
  • 26
    • 79961026393 scopus 로고    scopus 로고
    • Cardiac index in term pregnant women in the sitting, lateral, and supine positions: An observational, crossover study
    • 21642602 10.1213/ANE.0b013e31821f125c
    • Armstrong S, Fernando R, Columb M, Jones T. Cardiac index in term pregnant women in the sitting, lateral, and supine positions: an observational, crossover study. Anesth Analg. 2011;113:318-22.
    • (2011) Anesth Analg , vol.113 , pp. 318-322
    • Armstrong, S.1    Fernando, R.2    Columb, M.3    Jones, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.