메뉴 건너뛰기




Volumn 63, Issue 3, 2014, Pages 566-582

Multipurpose platform for power system monitoring and analysis with sample grid applications

Author keywords

Industrial power system testing; monitoring; power quality (PQ); power system measurements; power system monitoring

Indexed keywords

MONITORING; PHASOR MEASUREMENT UNITS; SYSTEMS ENGINEERING;

EID: 84894569586     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2013.2281556     Document Type: Article
Times cited : (55)

References (45)
  • 2
    • 58249136415 scopus 로고    scopus 로고
    • Synchronized power-quality measurement network with LAMP
    • Jan.
    • S. J. S. Tsai and C. C. Luo, "Synchronized power-quality measurement network with LAMP, " IEEE Trans Power Del., vol. 24, no. 1, pp. 484-485, Jan. 2009.
    • (2009) IEEE Trans Power Del. , vol.24 , Issue.1 , pp. 484-485
    • Tsai, S.J.S.1    Luo, C.C.2
  • 3
    • 60849135694 scopus 로고    scopus 로고
    • GPS-based system for the measurement of synchronized harmonic phasors
    • Mar.
    • A. Carta, N. Locci, and C. Muscas, "GPS-based system for the measurement of synchronized harmonic phasors, " IEEE Trans. Instrum. Meas., vol. 58, no. 3, pp. 586-593, Mar. 2009.
    • (2009) IEEE Trans. Instrum. Meas. , vol.58 , Issue.3 , pp. 586-593
    • Carta, A.1    Locci, N.2    Muscas, C.3
  • 4
    • 2342512184 scopus 로고    scopus 로고
    • A grid information resource for nationwide real-time power monitoring
    • Mar./Apr.
    • D. Divan, G. A. Luckjiff, W. E. Brumsickle, J. Freeborg, and A. Bhadkamkar, "A grid information resource for nationwide real-time power monitoring, " IEEE Trans. Ind. Appl., vol. 40, no. 2, pp. 699-704, Mar./Apr. 2004.
    • (2004) IEEE Trans. Ind. Appl. , vol.40 , Issue.2 , pp. 699-704
    • Divan, D.1    Luckjiff, G.A.2    Brumsickle, W.E.3    Freeborg, J.4    Bhadkamkar, A.5
  • 7
    • 1942440031 scopus 로고    scopus 로고
    • TransientMeter: A distributed measurement system for power quality monitoring
    • Apr.
    • P. Daponte, M. D. Penta, and G. Mercurio, "TransientMeter: A distributed measurement system for power quality monitoring, " IEEE Trans. Power Del., vol. 19, no. 2, pp. 456-463, Apr. 2004.
    • (2004) IEEE Trans. Power Del. , vol.19 , Issue.2 , pp. 456-463
    • Daponte, P.1    Penta, M.D.2    Mercurio, G.3
  • 11
    • 0027573826 scopus 로고
    • Synchronized phasor measurements in power systems
    • DOI 10.1109/67.207465
    • A. G. Phadke, "Synchronized phasor measurements in power systems, " IEEE Comput. Appl. Power, vol. 6, no. 2, pp. 10-15, Apr. 1993. (Pubitemid 23638773)
    • (1993) IEEE Computer Applications in Power , vol.6 , Issue.2 , pp. 10-15
    • Phadke, A.G.1
  • 14
    • 4544252954 scopus 로고    scopus 로고
    • Wide area system monitoring and control
    • D. Karlsson, M. Hemmingsson, and S. Lindahl, "Wide area system monitoring and control, " IEEE Power Energy Mag., vol. 2, no. 5, pp. 68-76, Sep./Oct. 2004.
    • (2004) IEEE Power Energy Mag. , vol.2 , Issue.5 , pp. 68-76
    • Karlsson, D.1    Hemmingsson, M.2    Lindahl, S.3
  • 15
    • 68349152789 scopus 로고    scopus 로고
    • Wide-area detection of voltage instability from synchronized phasor measurements. Part II: Simulation results
    • Aug.
    • M. Glavic and T. Van Cutsem, "Wide-area detection of voltage instability from synchronized phasor measurements. Part II: Simulation results, " IEEE Trans. Power Syst., vol. 24, no. 3, pp. 1417-1425, Aug. 2009.
    • (2009) IEEE Trans. Power Syst. , vol.24 , Issue.3 , pp. 1417-1425
    • Glavic, M.1    Van Cutsem, T.2
  • 16
    • 0037291007 scopus 로고    scopus 로고
    • Voltage-stability protection and control using a wide-area network of phasor measurements
    • Feb.
    • B. Milosevic and M. Begovic, "Voltage-stability protection and control using a wide-area network of phasor measurements, " IEEE Trans. Power Syst., vol. 18, no. 1, pp. 121-127, Feb. 2003.
    • (2003) IEEE Trans. Power Syst. , vol.18 , Issue.1 , pp. 121-127
    • Milosevic, B.1    Begovic, M.2
  • 17
    • 32344447275 scopus 로고    scopus 로고
    • Monitoring of interarea oscillation mode by synchronized phasor measurement
    • DOI 10.1109/TPWRS.2005.861960
    • N. Kakimoto, M. Sugumi, T. Makino, and K. Tomiyama, "Monitoring of interarea oscillation mode by synchronized phasor measurement, " IEEE Trans. Power Syst., vol. 21, no. 1, pp. 260-268, Feb. 2006. (Pubitemid 43216105)
    • (2006) IEEE Transactions on Power Systems , vol.21 , Issue.1 , pp. 260-268
    • Kakimoto, N.1    Sugumi, M.2    Makino, T.3    Tomiyama, K.4
  • 18
    • 0035248520 scopus 로고    scopus 로고
    • Wide-area measurement based stabilizing control of large power systems - A decentralized/hierarchical approach
    • DOI 10.1109/59.910791, PII S0885895001017722
    • I. Kamwa, R. Grondin, and Y. Hébert, "Wide-area measurement based stabilizing control of large power systems-A decentralized/hierarchical approach, " IEEE Trans. Power Syst., vol. 16, no. 1, pp. 136-153, Feb. 2001. (Pubitemid 32297479)
    • (2001) IEEE Transactions on Power Systems , vol.16 , Issue.1 , pp. 136-153
    • Kamwa, I.1    Grondin, R.2    Hebert, Y.3
  • 19
    • 39749086900 scopus 로고    scopus 로고
    • WAMS-based detection and early-warning of low-frequency oscillations in large-scale power systems
    • DOI 10.1016/j.epsr.2007.06.008, PII S0378779607001484
    • S. Zhang, X. Xie, and J. Wu, "WAMS based detection and early-warning of low frequency oscillations in large-scale power systems, " Electr. Power Syst. Res., vol. 78, no. 5, pp. 897-906, 2008. (Pubitemid 351305444)
    • (2008) Electric Power Systems Research , vol.78 , Issue.5 , pp. 897-906
    • Zhang, S.1    Xie, X.2    Wu, J.3
  • 21
    • 77956061246 scopus 로고    scopus 로고
    • Next generation monitoring, analysis, and control for the future smart control center
    • Sep.
    • P. Zhang, F. Li, and N. Bhatt, "Next generation monitoring, analysis, and control for the future smart control center, " IEEE Trans. Smart Grids, vol. 1, no. 2, pp. 186-192, Sep. 2010.
    • (2010) IEEE Trans. Smart Grids , vol.1 , Issue.2 , pp. 186-192
    • Zhang, P.1    Li, F.2    Bhatt, N.3
  • 22
    • 77952885648 scopus 로고    scopus 로고
    • Smart transmission grid applications and their supporting infrastructure
    • Jun.
    • A. Bose, "Smart transmission grid applications and their supporting infrastructure, " IEEE Trans. Smart Grids, vol. 1, no. 1, pp. 11-19, Jun. 2010.
    • (2010) IEEE Trans. Smart Grids , vol.1 , Issue.1 , pp. 11-19
    • Bose, A.1
  • 29
    • 77956926302 scopus 로고    scopus 로고
    • A new flicker contribution tracing method based on individual reactive current components of multiple EAFs at PCC
    • Sep./Oct.
    • E. Altintas, O. Salor, I. Cadirci, and M. Ermis, "A new flicker contribution tracing method based on individual reactive current components of multiple EAFs at PCC, " IEEE Trans. Ind. Appl., vol. 46, no. 5, pp. 1746-1754, Sep./Oct. 2010.
    • (2010) IEEE Trans. Ind. Appl. , vol.46 , Issue.5 , pp. 1746-1754
    • Altintas, E.1    Salor, O.2    Cadirci, I.3    Ermis, M.4
  • 30
    • 84863493124 scopus 로고    scopus 로고
    • Determination of harmonic current contributions at points of common coupling of the electrical system based on field measurements
    • O. Unsar, O. Salor, I. Cadirci, and M. Ermis, "Determination of harmonic current contributions at points of common coupling of the electrical system based on field measurements, " in Proc. 20th IEEE Signal Process. Commun. Appl. Conf., Apr. 2012, pp. 1-4.
    • (2012) Proc. 20th IEEE Signal Process. Commun. Appl. Conf., Apr. , pp. 1-4
    • Unsar, O.1    Salor, O.2    Cadirci, I.3    Ermis, M.4
  • 33
  • 38
    • 84894586655 scopus 로고    scopus 로고
    • Electrical interconnection between Turkey and Europe: Problems and solutions
    • Dec.
    • H. Weber and I. Nassar, "Electrical interconnection between Turkey and Europe: Problems and solutions, " in Proc. 13th MEPCON, Dec. 2009, pp. 20-23.
    • (2009) Proc. 13th MEPCON , pp. 20-23
    • Weber, H.1    Nassar, I.2
  • 39
    • 78751489467 scopus 로고    scopus 로고
    • Damping measures against prospective oscillations between turkish grid and ENTSO-E system
    • Tor, C. Gencoglu, O. Yilmaz, E. Cebeci, and N. Guven
    • O. B. Tor, C. Gencoglu, O. Yilmaz, E. Cebeci, and N. Guven, "Damping measures against prospective oscillations between turkish grid and ENTSO-E system, " in Proc. IEEE Int. Conf. Power Syst. Technol., Oct. 2010, pp. 1-7.
    • (2010) Proc. IEEE Int. Conf. Power Syst. Technol., Oct. , pp. 1-7
  • 42
    • 84864559722 scopus 로고    scopus 로고
    • Multi-DSP and-FPGA-based fully-digital control system for cascaded multilevel converters used in FACTS applications
    • Aug.
    • T. Atalik, M. Deniz, E. Koc, C. O. Gercek, B. Gultekin, M. Ermis, and I. Cadirci, "Multi-DSP and-FPGA-based fully-digital control system for cascaded multilevel converters used in FACTS applications, " IEEE Trans. Ind. Inf., vol. 8, no. 3, pp. 511-527, Aug. 2012.
    • (2012) IEEE Trans. Ind. Inf. , vol.8 , Issue.3 , pp. 511-527
    • Atalik, T.1    Deniz, M.2    Koc, E.3    Gercek, C.O.4    Gultekin, B.5    Ermis, M.6    Cadirci, I.7
  • 43
    • 84864131921 scopus 로고    scopus 로고
    • Medium frequency induction melting furnace as a load on the power system
    • I. Yilmaz, M. Ermis, and I. Cadirci, "Medium frequency induction melting furnace as a load on the power system, " IEEE Trans. Ind. Appl., vol. 48, no. 4, pp. 1203-1214, Jul./Aug. 2012.
    • IEEE Trans. Ind. Appl. , vol.48 , Issue.4 , pp. 1203-1214
    • Yilmaz, I.1    Ermis, M.2    Cadirci, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.