메뉴 건너뛰기




Volumn 42, Issue 3, 2014, Pages 701-711

Assessment of limb muscle strength in critically ill Patients: A systematic Review

Author keywords

adult; critical illness; muscle strength; muscle strength dynamometer; muscle weakness; reliability of results

Indexed keywords

ADULT; CRITICAL ILLNESS; FEMALE; HUMANS; INTENSIVE CARE UNITS; LOWER EXTREMITY; MALE; MUSCLE STRENGTH; MUSCLE STRENGTH DYNAMOMETER; MUSCLE WEAKNESS; MUSCLE, SKELETAL; OBSERVATIONAL STUDY AS TOPIC; OBSERVER VARIATION; PROGNOSIS; REPRODUCIBILITY OF RESULTS; UPPER EXTREMITY;

EID: 84894496101     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0000000000000030     Document Type: Review
Times cited : (124)

References (33)
  • 1
    • 84870679618 scopus 로고    scopus 로고
    • Global muscle strength but not grip strength predicts mortality and length of stay in a general population in a surgical intensive care unit
    • Lee JJ, Waak K, Grosse-Sundrup M, et al: Global muscle strength but not grip strength predicts mortality and length of stay in a general population in a surgical intensive care unit. Phys Ther 2012; 92:1546-1555
    • (2012) Phys Ther , vol.92 , pp. 1546-1555
    • Lee, J.J.1    Waak, K.2    Grosse-Sundrup, M.3
  • 2
    • 48249119523 scopus 로고    scopus 로고
    • Acquired weakness handgrip strength and mortality in critically ill patients
    • Midwest Critical Care Consortium
    • Ali NA, OBrien JM Jr, Hoffmann SP, et al; Midwest Critical Care Consortium: Acquired weakness, handgrip strength, and mortality in critically ill patients. Am J Respir Crit Care Med 2008; 178:261-268
    • (2008) Am J Respir Crit Care Med , vol.178 , pp. 261-268
    • Ali, N.A.1    Obrien Jr., J.M.2    Hoffmann, S.P.3
  • 3
    • 5044229556 scopus 로고    scopus 로고
    • Functional outcome in patients with critical illness polyneuropathy
    • van der Schaaf M, Beelen A, de Vos R: Functional outcome in patients with critical illness polyneuropathy. Disabil Rehabil 2004; 26:1189-1197
    • (2004) Disabil Rehabil , vol.26 , pp. 1189-1197
    • Van Der Schaaf, M.1    Beelen, A.2    De Vos, R.3
  • 4
    • 79953775836 scopus 로고    scopus 로고
    • Canadian Critical Care Trials Group: Functional disability 5 years after acute respiratory distress syndrome
    • Herridge MS, Tansey CM, Matt A, et al; Canadian Critical Care Trials Group: Functional disability 5 years after acute respiratory distress syndrome. N Engl J Med 2011; 364:1293-1304
    • (2011) N Engl J Med , vol.364 , pp. 1293-1304
    • Herridge, M.S.1    Tansey, C.M.2    Matt, A.3
  • 5
    • 70350517765 scopus 로고    scopus 로고
    • A framework for diagnosing and classifying intensive care unit-Acquired weakness
    • Stevens RD, Marshall SA, Cornblath DR, et al: A framework for diagnosing and classifying intensive care unit-Acquired weakness. Crit Care Med 2009; 37:S299-S308
    • (2009) Crit Care Med , vol.37
    • Stevens, R.D.1    Marshall, S.A.2    Cornblath, D.R.3
  • 6
    • 0035153901 scopus 로고    scopus 로고
    • Measuring knee extensor muscle strength
    • Bohannon RW: Measuring knee extensor muscle strength. Am J Phys Med Rehabil 2001; 80:13-18
    • (2001) Am J Phys Med Rehabil , vol.80 , pp. 13-18
    • Bohannon, R.W.1
  • 7
    • 24944456834 scopus 로고    scopus 로고
    • Manual muscle testing: Does it meet the standards of an adequate screening test?
    • Bohannon RW: Manual muscle testing: Does it meet the standards of an adequate screening test? Clin Rehabil 2005; 19:662-667
    • (2005) Clin Rehabil , vol.19 , pp. 662-667
    • Bohannon, R.W.1
  • 8
    • 0026465529 scopus 로고
    • Relationship between two measures of upper extremity strength: Manual muscle test compared to hand-held myometry
    • Schwartz S, Cohen ME, Herbison GJ, et al: Relationship between two measures of upper extremity strength: Manual muscle test compared to hand-held myometry. Arch Phys Med Rehabil 1992; 73:1063-1068
    • (1992) Arch Phys Med Rehabil , vol.73 , pp. 1063-1068
    • Schwartz, S.1    Cohen, M.E.2    Herbison, G.J.3
  • 9
    • 0026050521 scopus 로고
    • Interobserver agreement in the assessment of muscle strength and functional abilities in Guillain-Barr syndrome
    • Kleyweg RP, van der Mech FG, Schmitz PI: Interobserver agreement in the assessment of muscle strength and functional abilities in Guillain-Barr syndrome. Muscle Nerve 1991; 14:1103-1109
    • (1991) Muscle Nerve , vol.14 , pp. 1103-1109
    • Kleyweg, R.P.1    Van Der Mech, F.G.2    Schmitz, P.I.3
  • 10
    • 0037065331 scopus 로고    scopus 로고
    • Groupe de Rflexion et dEtude des Neuromyopathies en Ranimation: Paresis acquired in the intensive care unit: A prospective multicenter study
    • De Jonghe B, Sharshar T, Lefaucheur JP, et al; Groupe de Rflexion et dEtude des Neuromyopathies en Ranimation: Paresis acquired in the intensive care unit: A prospective multicenter study. JAMA 2002; 288:2859-2867
    • (2002) JAMA , vol.288 , pp. 2859-2867
    • De Jonghe, B.1    Sharshar, T.2    Lefaucheur, J.P.3
  • 11
    • 0031021783 scopus 로고    scopus 로고
    • Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years
    • Bohannon RW: Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years. Arch Phys Med Rehabil 1997; 78:26-32
    • (1997) Arch Phys Med Rehabil , vol.78 , pp. 26-32
    • Bohannon, R.W.1
  • 12
    • 0029963026 scopus 로고    scopus 로고
    • Normative values for isometric muscle force measurements obtained with hand-held dynamometers
    • Andrews AW, Thomas MW, Bohannon RW: Normative values for isometric muscle force measurements obtained with hand-held dynamometers. Phys Ther 1996; 76:248-259
    • (1996) Phys Ther , vol.76 , pp. 248-259
    • Andrews, A.W.1    Thomas, M.W.2    Bohannon, R.W.3
  • 13
    • 21344437280 scopus 로고    scopus 로고
    • Break-technique handheld dynamometry: Relation between angular velocity and strength measurements
    • Burns SP, Spanier DE: Break-technique handheld dynamometry: Relation between angular velocity and strength measurements. Arch Phys Med Rehabil 2005; 86:1420-1426
    • (2005) Arch Phys Med Rehabil , vol.86 , pp. 1420-1426
    • Burns, S.P.1    Spanier, D.E.2
  • 14
    • 77953557449 scopus 로고    scopus 로고
    • The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: An international Delphi study
    • Mokkink LB, Terwee CB, Patrick DL, et al: The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: An international Delphi study. Qual Life Res 2010; 19:539-549
    • (2010) Qual Life Res , vol.19 , pp. 539-549
    • Mokkink, L.B.1    Terwee, C.B.2    Patrick, D.L.3
  • 15
    • 0033924835 scopus 로고    scopus 로고
    • Adductor pollicis twitch tension assessed by magnetic stimulation of the ulnar nerve
    • Harris ML, Luo YM, Watson AC, et al: Adductor pollicis twitch tension assessed by magnetic stimulation of the ulnar nerve. Am J Respir Crit Care Med 2000; 162:240-245
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 240-245
    • Harris, M.L.1    Luo, Y.M.2    Watson, A.C.3
  • 16
    • 77956831300 scopus 로고    scopus 로고
    • Inter-rater agreement and reliability of the COSMIN (COnsensus-based Standards for the selection of health status Measurement Instruments) checklist
    • Mokkink LB, Terwee CB, Gibbons E, et al: Inter-rater agreement and reliability of the COSMIN (COnsensus-based Standards for the selection of health status Measurement Instruments) checklist. BMC Med Res Methodol 2010; 10:82
    • (2010) BMC Med Res Methodol , vol.10 , pp. 82
    • Mokkink, L.B.1    Terwee, C.B.2    Gibbons, E.3
  • 17
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 1977; 33:159-174
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 18
    • 84555187478 scopus 로고    scopus 로고
    • Interobserver agreement of Medical Research Council sum-score and handgrip strength in the intensive care unit
    • Hermans G, Clerckx B, Vanhullebusch T, et al: Interobserver agreement of Medical Research Council sum-score and handgrip strength in the intensive care unit. Muscle Nerve 2012; 45:18-25
    • (2012) Muscle Nerve , vol.45 , pp. 18-25
    • Hermans, G.1    Clerckx, B.2    Vanhullebusch, T.3
  • 19
    • 79251583724 scopus 로고    scopus 로고
    • Manual muscle strength testing of critically ill patients: Feasibility and interobserver agreement
    • Hough CL, Lieu BK, Caldwell ES: Manual muscle strength testing of critically ill patients: Feasibility and interobserver agreement. Crit Care 2011; 15:R43
    • (2011) Crit Care , vol.15
    • Hough, C.L.1    Lieu, B.K.2    Caldwell, E.S.3
  • 20
    • 77954456408 scopus 로고    scopus 로고
    • Inter-rater reliability of manual muscle strength testing in ICU survivors and simulated patients
    • Fan E, Ciesla ND, Truong AD, et al: Inter-rater reliability of manual muscle strength testing in ICU survivors and simulated patients. Intensive Care Med 2010; 36:1038-1043
    • (2010) Intensive Care Med , vol.36 , pp. 1038-1043
    • Fan, E.1    Ciesla, N.D.2    Truong, A.D.3
  • 21
    • 79961029400 scopus 로고    scopus 로고
    • The interobserver agreement of handheld dynamometry for muscle strength assessment in critically ill patients
    • Vanpee G, Segers J, Van Mechelen H, et al: The interobserver agreement of handheld dynamometry for muscle strength assessment in critically ill patients. Crit Care Med 2011; 39:1929-1934
    • (2011) Crit Care Med , vol.39 , pp. 1929-1934
    • Vanpee, G.1    Segers, J.2    Van Mechelen, H.3
  • 22
    • 84870813887 scopus 로고    scopus 로고
    • Muscle strength assessment in critically ill patients with handheld dynamometry: An investigation of reliability, minimal detectable change, and time to peak force generation
    • Baldwin CE, Paratz JD, Bersten AD: Muscle strength assessment in critically ill patients with handheld dynamometry: An investigation of reliability, minimal detectable change, and time to peak force generation. J Crit Care 2013; 28:77-86
    • (2013) J Crit Care , vol.28 , pp. 77-86
    • Baldwin, C.E.1    Paratz, J.D.2    Bersten, A.D.3
  • 23
    • 21244433980 scopus 로고    scopus 로고
    • Are factor analytical techniques used appropriately in the validation of health status questionnaires? A systematic review on the quality of factor analysis of the SF-36
    • discussion 1219
    • de Vet HC, Adr HJ, Terwee CB, et al: Are factor analytical techniques used appropriately in the validation of health status questionnaires? A systematic review on the quality of factor analysis of the SF-36. Qual Life Res 2005; 14:1203-1218; discussion 1219
    • (2005) Qual Life Res , vol.14 , pp. 1203-1218
    • De Vet, H.C.1    Adr, H.J.2    Terwee, C.B.3
  • 24
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • Shrout PE, Fleiss JL: Intraclass correlations: Uses in assessing rater reliability. Psychol Bull 1979; 86:420-428
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 25
    • 0025778838 scopus 로고
    • The relationship between muscle mass and muscle strength in the elderly
    • Reed RL, Pearlmutter L, Yochum K, et al: The relationship between muscle mass and muscle strength in the elderly. J Am Geriatr Soc 1991; 39:555-561
    • (1991) J Am Geriatr Soc , vol.39 , pp. 555-561
    • Reed, R.L.1    Pearlmutter, L.2    Yochum, K.3
  • 26
    • 0020645216 scopus 로고
    • Strength and cross-sectional area of human skeletal muscle
    • Maughan RJ, Watson JS, Weir J: Strength and cross-sectional area of human skeletal muscle. J Physiol 1983; 338:37-49
    • (1983) J Physiol , vol.338 , pp. 37-49
    • Maughan, R.J.1    Watson, J.S.2    Weir, J.3
  • 27
    • 0031985729 scopus 로고    scopus 로고
    • Muscle strength and functional mobility in relation to lean body mass in free-living frail elderly women
    • Payette H, Hanusaik N, Boutier V, et al: Muscle strength and functional mobility in relation to lean body mass in free-living frail elderly women. Eur J Clin Nutr 1998; 52:45-53
    • (1998) Eur J Clin Nutr , vol.52 , pp. 45-53
    • Payette, H.1    Hanusaik, N.2    Boutier, V.3
  • 28
    • 1642527377 scopus 로고    scopus 로고
    • Muscle wasting and energy balance in critical illness
    • Reid CL, Campbell IT, Little RA: Muscle wasting and energy balance in critical illness. Clin Nutr 2004; 23:273-280
    • (2004) Clin Nutr , vol.23 , pp. 273-280
    • Reid, C.L.1    Campbell, I.T.2    Little, R.A.3
  • 29
    • 41349122451 scopus 로고    scopus 로고
    • Muscle wasting in intensive care patients: Ultrasound observation of the M quadriceps femoris muscle layer
    • Gruther W, Benesch T, Zorn C, et al: Muscle wasting in intensive care patients: Ultrasound observation of the M. quadriceps femoris muscle layer. J Rehabil Med 2008; 40:185-189
    • (2008) J Rehabil Med , vol.40 , pp. 185-189
    • Gruther, W.1    Benesch, T.2    Zorn, C.3
  • 30
    • 58449127222 scopus 로고    scopus 로고
    • Clinical review: Critical illness polyneuropathy and myopathy
    • Hermans G, De Jonghe B, Bruyninckx F, et al: Clinical review: Critical illness polyneuropathy and myopathy. Crit Care 2008; 12:238
    • (2008) Crit Care , vol.12 , pp. 238
    • Hermans, G.1    De Jonghe, B.2    Bruyninckx, F.3
  • 31
    • 3042589668 scopus 로고    scopus 로고
    • Does ICU-Acquired paresis lengthen weaning from mechanical ventilation?
    • De Jonghe B, Bastuji-Garin S, Sharshar T, et al: Does ICU-Acquired paresis lengthen weaning from mechanical ventilation? Intensive Care Med 2004; 30:1117-1121
    • (2004) Intensive Care Med , vol.30 , pp. 1117-1121
    • De Jonghe, B.1    Bastuji-Garin, S.2    Sharshar, T.3
  • 32
    • 41649111939 scopus 로고    scopus 로고
    • Is it legitimate to characterize muscle strength using a limited number of measures?
    • Bohannon RW: Is it legitimate to characterize muscle strength using a limited number of measures? J Strength Cond Res 2008; 22:166-173
    • (2008) J Strength Cond Res , vol.22 , pp. 166-173
    • Bohannon, R.W.1
  • 33
    • 42549144506 scopus 로고    scopus 로고
    • Hand-grip dynamometry predicts future outcomes in aging adults
    • Bohannon RW: Hand-grip dynamometry predicts future outcomes in aging adults. J Geriatr Phys Ther 2008; 31:3-10
    • (2008) J Geriatr Phys Ther , vol.31 , pp. 3-10
    • Bohannon, R.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.