메뉴 건너뛰기




Volumn 129, Issue 7, 2014, Pages 811-822

Future of implantable devices for cardiac rhythm management

Author keywords

[No Author keywords available]

Indexed keywords

ARRHYTHMIAS, CARDIAC; CARDIAC RESYNCHRONIZATION THERAPY; DEFIBRILLATORS, IMPLANTABLE; HEART FAILURE; PACEMAKER, ARTIFICIAL;

EID: 84894303668     PISSN: 00097322     EISSN: 15244539     Source Type: Journal    
DOI: 10.1161/CIRCULATIONAHA.112.000312     Document Type: Article
Times cited : (19)

References (100)
  • 5
    • 84882861500 scopus 로고    scopus 로고
    • Chronic animal study of leadless pacer design [abstract]
    • Bonner MD, Eggen MD. Chronic animal study of leadless pacer design [abstract]. Heart Rhythm. 2011;8:S1.
    • (2011) Heart Rhythm. , vol.8 , pp. 1
    • Bonner, M.D.1    Eggen, M.D.2
  • 7
    • 84873390747 scopus 로고    scopus 로고
    • Vibration powered cardiac rhythm devices [abstract]
    • Karami MA, Bradley DJ, Inman DJ. Vibration powered cardiac rhythm devices [abstract]. Circulation. 2012;126:A15551.
    • (2012) Circulation. , vol.126 , pp. 15551
    • Karami, M.A.1    Bradley, D.J.2    Inman, D.J.3
  • 8
    • 0032993495 scopus 로고    scopus 로고
    • Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source
    • Goto H, Sugiura T, Harada Y, Kazui T. Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source. Med Biol Eng Comput. 1999;37:377-380.
    • (1999) Med Biol Eng Comput. , vol.37 , pp. 377-380
    • Goto, H.1    Sugiura, T.2    Harada, Y.3    Kazui, T.4
  • 9
    • 33749080941 scopus 로고    scopus 로고
    • Feasibility and safety of a novel technology for pacing without leads
    • Echt DS, Cowan MW, Riley RE, Brisken AF. Feasibility and safety of a novel technology for pacing without leads. Heart Rhythm. 2006;3:1202-1206.
    • (2006) Heart Rhythm. , vol.3 , pp. 1202-1206
    • Echt, D.S.1    Cowan, M.W.2    Riley, R.E.3    Brisken, A.F.4
  • 10
    • 34547931047 scopus 로고    scopus 로고
    • First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: Implications for wireless pacing with implantable devices
    • Lee KL, Lau CP, Tse HF, Echt DS, Heaven D, Smith W, Hood M. First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: Implications for wireless pacing with implantable devices. J Am Coll Cardiol. 2007;50:877-883.
    • (2007) J Am Coll Cardiol. , vol.50 , pp. 877-883
    • Lee, K.L.1    Lau, C.P.2    Tse, H.F.3    Echt, D.S.4    Heaven, D.5    Smith, W.6    Hood, M.7
  • 11
    • 65649133577 scopus 로고    scopus 로고
    • Temporary leadless pacing in heart failure patients with ultrasound-mediated stimulation energy and effects on the acoustic window
    • Lee KL, Tse HF, Echt DS, Lau CP. Temporary leadless pacing in heart failure patients with ultrasound-mediated stimulation energy and effects on the acoustic window. Heart Rhythm. 2009;6:742-748.
    • (2009) Heart Rhythm. , vol.6 , pp. 742-748
    • Lee, K.L.1    Tse, H.F.2    Echt, D.S.3    Lau, C.P.4
  • 12
    • 84880959315 scopus 로고    scopus 로고
    • Chronic implantation of leadless pacing electrodes in the left ventricle of a goat model [abstract]
    • Echt DS, Moore D, Cowan M, Valli VE, Whitehair JG, Willis NP. Chronic implantation of leadless pacing electrodes in the left ventricle of a goat model [abstract]. Heart Rhythm 2010;7:S451-S452.
    • (2010) Heart Rhythm , vol.7 , pp. 451-452
    • Echt, D.S.1    Moore, D.2    Cowan, M.3    Valli, V.E.4    Whitehair, J.G.5    Willis, N.P.6
  • 13
    • 58849120512 scopus 로고    scopus 로고
    • Leadless pacing of the heart using induction technology: A feasibility study
    • Wieneke H, Konorza T, Erbel R, Kisker E. Leadless pacing of the heart using induction technology: A feasibility study. Pacing Clin Electrophysiol. 2009;32:177-183.
    • (2009) Pacing Clin Electrophysiol. , vol.32 , pp. 177-183
    • Wieneke, H.1    Konorza, T.2    Erbel, R.3    Kisker, E.4
  • 15
    • 26444431999 scopus 로고    scopus 로고
    • Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure: Combined results of over 2,000 patients from a multicenter study program
    • MIRACLE Study Program.
    • León AR, Abraham WT, Curtis AB, Daubert JP, Fisher WG, Gurley J, Hayes DL, Lieberman R, Petersen-Stejskal S, Wheelan K; MIRACLE Study Program. Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure: Combined results of over 2,000 patients from a multicenter study program. J Am Coll Cardiol. 2005;46:2348-2356.
    • (2005) J Am Coll Cardiol. , vol.46 , pp. 2348-2356
    • León, A.R.1    Abraham, W.T.2    Curtis, A.B.3    Daubert, J.P.4    Fisher, W.G.5    Gurley, J.6    Hayes, D.L.7    Lieberman, R.8    Petersen-Stejskal, S.9    Wheelan, K.10
  • 16
    • 78650700438 scopus 로고    scopus 로고
    • Primary results from the smartdelay determined av optimization: A comparison to other av delay methods used in cardiac resynchronization therapy (smart-av) trial: A randomized trial comparing empirical, echocardiography- guided, and algorithmic atrioventricular delay programming in cardiac resynchronization therapy
    • Ellenbogen KA, Gold MR, Meyer TE, Fernndez Lozano I, Mittal S, Waggoner AD, Lemke B, Singh JP, Spinale FG, Van Eyk JE, Whitehill J, Weiner S, Bedi M, Rapkin J, Stein KM. Primary results from the SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy (SMART-AV) trial: A randomized trial comparing empirical, echocardiography-guided, and algorithmic atrioventricular delay programming in cardiac resynchronization therapy. Circulation. 2010;122:2660-2668.
    • (2010) Circulation. , vol.122 , pp. 2660-2668
    • Ellenbogen, K.A.1    Gold, M.R.2    Meyer, T.E.3    Fernndez Lozano, I.4    Mittal, S.5    Waggoner, A.D.6    Lemke, B.7    Singh, J.P.8    Spinale, F.G.9    Van Eyk, J.E.10    Whitehill, J.11    Weiner, S.12    Bedi, M.13    Rapkin, J.14    Stein, K.M.15
  • 18
    • 84861129066 scopus 로고    scopus 로고
    • Local electrogram delay recorded from left ventricular lead at implant predicts response to cardiac resynchronization therapy: Retrospective study with 1 year follow up
    • Polasek R, Kucera P, Nedbal P, Roubicek T, Belza T, Hanuliakova J, Horak D, Wichterle D, Kautzner J. Local electrogram delay recorded from left ventricular lead at implant predicts response to cardiac resynchronization therapy: Retrospective study with 1 year follow up. BMC Cardiovasc Disord. 2012;12:34.
    • (2012) BMC Cardiovasc Disord. , vol.12 , pp. 34
    • Polasek, R.1    Kucera, P.2    Nedbal, P.3    Roubicek, T.4    Belza, T.5    Hanuliakova, J.6    Horak, D.7    Wichterle, D.8    Kautzner, J.9
  • 20
    • 84874631042 scopus 로고    scopus 로고
    • Video-assisted thoracoscopic left ventricular pacing in patients with and without previous sternotomy
    • Nelson KE, Bates MG, Turley AJ, Linker NJ, Owens WA. Video-assisted thoracoscopic left ventricular pacing in patients with and without previous sternotomy. Ann Thorac Surg. 2013;95:907-913.
    • (2013) Ann Thorac Surg. , vol.95 , pp. 907-913
    • Nelson, K.E.1    Bates, M.G.2    Turley, A.J.3    Linker, N.J.4    Owens, W.A.5
  • 21
    • 84857424094 scopus 로고    scopus 로고
    • Endurance and performance of two different concepts for left ventricular stimulation with bipolar epicardial leads in long-term follow-up
    • Burger H, Kempfert J, van Linden A, Szalay Z, Schoenburg M, Walther T, Ziegelhoeffer T. Endurance and performance of two different concepts for left ventricular stimulation with bipolar epicardial leads in long-term follow-up. Thorac Cardiovasc Surg. 2012;60:70-77.
    • (2012) Thorac Cardiovasc Surg. , vol.60 , pp. 70-77
    • Burger, H.1    Kempfert, J.2    Van Linden, A.3    Szalay, Z.4    Schoenburg, M.5    Walther, T.6    Ziegelhoeffer, T.7
  • 22
  • 28
    • 65249144453 scopus 로고    scopus 로고
    • Targeted left ventricular endocardial pacing using a steerable introducing guide catheter and active fixation pacing lead
    • Morgan JM, Scott PA, Turner NG, Yue AM, Roberts PR. Targeted left ventricular endocardial pacing using a steerable introducing guide catheter and active fixation pacing lead. Europace. 2009;11:502-506.
    • (2009) Europace. , vol.11 , pp. 502-506
    • Morgan, J.M.1    Scott, P.A.2    Turner, N.G.3    Yue, A.M.4    Roberts, P.R.5
  • 29
    • 0032752070 scopus 로고    scopus 로고
    • Left ventricular lead insertion using a modified transseptal catheterization technique: A totally endocardial approach for permanent biventricular pacing in end-stage heart failure
    • Leclercq F, Hager FX, Macia JC, Mariottini CJ, Pasquié JL, Grolleau R. Left ventricular lead insertion using a modified transseptal catheterization technique: A totally endocardial approach for permanent biventricular pacing in end-stage heart failure. Pacing Clin Electrophysiol. 1999;22:1570-1575.
    • (1999) Pacing Clin Electrophysiol. , vol.22 , pp. 1570-1575
    • Leclercq, F.1    Hager, F.X.2    Macia, J.C.3    Mariottini, C.J.4    Pasquié, J.L.5    Grolleau, R.6
  • 30
    • 74449091263 scopus 로고    scopus 로고
    • System survival of nontransvenous implantable cardioverter-defibrillators compared to transvenous implantable cardioverter-defibrillators in pediatric and congenital heart disease patients
    • Radbill AE, Triedman JK, Berul CI, Fynn-Thompson F, Atallah J, Alexander ME, Walsh EP, Cecchin F. System survival of nontransvenous implantable cardioverter-defibrillators compared to transvenous implantable cardioverter-defibrillators in pediatric and congenital heart disease patients. Heart Rhythm. 2010;7:193-198.
    • (2010) Heart Rhythm. , vol.7 , pp. 193-198
    • Radbill, A.E.1    Triedman, J.K.2    Berul, C.I.3    Fynn-Thompson, F.4    Atallah, J.5    Alexander, M.E.6    Walsh, E.P.7    Cecchin, F.8
  • 31
    • 78049466571 scopus 로고    scopus 로고
    • An alternative technique of implanting a nontransvenous implantable cardioverter-defibrillator system in adults with no or limited venous access to the heart
    • Kowalski M, Nicolato P, Kalahasty G, Kasirajan V, Wood MA, Ellenbogen KA, Shepard RK. An alternative technique of implanting a nontransvenous implantable cardioverter-defibrillator system in adults with no or limited venous access to the heart. Heart Rhythm. 2010;7:1572-1577.
    • (2010) Heart Rhythm. , vol.7 , pp. 1572-1577
    • Kowalski, M.1    Nicolato, P.2    Kalahasty, G.3    Kasirajan, V.4    Wood, M.A.5    Ellenbogen, K.A.6    Shepard, R.K.7
  • 32
    • 44449150680 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillator lead performance
    • Maisel WH, Kramer DB. Implantable cardioverter-defibrillator lead performance. Circulation. 2008;117:2721-2723.
    • (2008) Circulation. , vol.117 , pp. 2721-2723
    • Maisel, W.H.1    Kramer, D.B.2
  • 33
    • 80052085302 scopus 로고    scopus 로고
    • Implantation-related complications of implantable cardioverter- defibrillators and cardiac resynchronization therapy devices: A systematic review of randomized clinical trials
    • van Rees JB, De Bie MK, Thijssen J, Borleffs CJ, Schalij MJ, van Erven L. Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: A systematic review of randomized clinical trials. J Am Coll Cardiol. 2011;58:995-1000.
    • (2011) J Am Coll Cardiol. , vol.58 , pp. 995-1000
    • Van Rees, J.B.1    De Bie, M.K.2    Thijssen, J.3    Borleffs, C.J.4    Schalij, M.J.5    Van Erven, L.6
  • 36
    • 84862128354 scopus 로고    scopus 로고
    • Development of an entirely subcutaneous implantable cardioverter- defibrillator
    • Lupo PP, Pelissero G, Ali H, Sanghera R, Cappato R. Development of an entirely subcutaneous implantable cardioverter-defibrillator. Prog Cardiovasc Dis. 2012;54:493-497.
    • (2012) Prog Cardiovasc Dis. , vol.54 , pp. 493-497
    • Lupo, P.P.1    Pelissero, G.2    Ali, H.3    Sanghera, R.4    Cappato, R.5
  • 40
    • 67549089543 scopus 로고    scopus 로고
    • Multiple monophasic shocks improve electrotherapy of ventricular tachycardia in a rabbit model of chronic infarction
    • Li W, Ripplinger CM, Lou Q, Efimov IR. Multiple monophasic shocks improve electrotherapy of ventricular tachycardia in a rabbit model of chronic infarction. Heart Rhythm. 2009;6:1020-1027.
    • (2009) Heart Rhythm. , vol.6 , pp. 1020-1027
    • Li, W.1    Ripplinger, C.M.2    Lou, Q.3    Efimov, I.R.4
  • 41
    • 84863337831 scopus 로고    scopus 로고
    • Low-energy multistage atrial defibrillation therapy terminates atrial fibrillation with less energy than a single shock
    • Li W, Janardhan AH, Fedorov VV, Sha Q, Schuessler RB, Efimov IR. Low-energy multistage atrial defibrillation therapy terminates atrial fibrillation with less energy than a single shock. Circ Arrhythm Electrophysiol. 2011;4:917-925.
    • (2011) Circ Arrhythm Electrophysiol. , vol.4 , pp. 917-925
    • Li, W.1    Janardhan, A.H.2    Fedorov, V.V.3    Sha, Q.4    Schuessler, R.B.5    Efimov, I.R.6
  • 42
    • 84870504723 scopus 로고    scopus 로고
    • A novel low-energy electrotherapy that terminates ventricular tachycardia with lower energy than a biphasic shock when antitachycardia pacing fails
    • Janardhan AH, Li W, Fedorov VV, Yeung M, Wallendorf MJ, Schuessler RB, Efimov IR. A novel low-energy electrotherapy that terminates ventricular tachycardia with lower energy than a biphasic shock when antitachycardia pacing fails. J Am Coll Cardiol. 2012;60:2393-2398.
    • (2012) J Am Coll Cardiol. , vol.60 , pp. 2393-2398
    • Janardhan, A.H.1    Li, W.2    Fedorov, V.V.3    Yeung, M.4    Wallendorf, M.J.5    Schuessler, R.B.6    Efimov, I.R.7
  • 44
    • 0037123144 scopus 로고    scopus 로고
    • Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation
    • Mitchell LB, Pineda EA, Titus JL, Bartosch PM, Benditt DG. Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation. J Am Coll Cardiol. 2002;39:1323-1328.
    • (2002) J Am Coll Cardiol. , vol.39 , pp. 1323-1328
    • Mitchell, L.B.1    Pineda, E.A.2    Titus, J.L.3    Bartosch, P.M.4    Benditt, D.G.5
  • 46
    • 4644325714 scopus 로고    scopus 로고
    • Electrical therapy for post defibrillatory pulseless electrical activity
    • Rosborough JP, Deno DC. Electrical therapy for post defibrillatory pulseless electrical activity. Resuscitation. 2004;63:65-72.
    • (2004) Resuscitation. , vol.63 , pp. 65-72
    • Rosborough, J.P.1    Deno, D.C.2
  • 49
    • 82455181371 scopus 로고    scopus 로고
    • Utility of a novel watch-based pulse detection system to detect pulselessness in human subjects
    • Rickard J, Ahmed S, Baruch M, Klocman B, Martin DO, Menon V. Utility of a novel watch-based pulse detection system to detect pulselessness in human subjects. Heart Rhythm. 2011;8:1895-1899.
    • (2011) Heart Rhythm. , vol.8 , pp. 1895-1899
    • Rickard, J.1    Ahmed, S.2    Baruch, M.3    Klocman, B.4    Martin, D.O.5    Menon, V.6
  • 52
    • 0024497513 scopus 로고
    • The limited reliability of physical signs for estimating hemodynamics in chronic heart failure
    • Stevenson LW, Perloff JK. The limited reliability of physical signs for estimating hemodynamics in chronic heart failure. JAMA. 1989;261:884-888.
    • (1989) JAMA. , vol.261 , pp. 884-888
    • Stevenson, L.W.1    Perloff, J.K.2
  • 53
    • 0037097468 scopus 로고    scopus 로고
    • Pacing Therapies in Congestive Heart Failure. A novel method-The activity log index-for monitoring physical activity of patients with heart failure
    • PATH-CHF Study Group
    • Kadhiresan VA, Pastore J, Auricchio A, Sack S, Doelger A, Girouard S, Spinelli JC; PATH-CHF Study Group, Pacing Therapies in Congestive Heart Failure. A novel method-The activity log index-for monitoring physical activity of patients with heart failure. Am J Cardiol. 2002;89:1435-1437.
    • (2002) Am J Cardiol. , vol.89 , pp. 1435-1437
    • Kadhiresan, V.A.1    Pastore, J.2    Auricchio, A.3    Sack, S.4    Doelger, A.5    Girouard, S.6    Spinelli, J.C.7
  • 56
    • 84857117780 scopus 로고    scopus 로고
    • Impact of continuous intracardiac ST-segment monitoring on mid-term outcomes of ICD-implanted patients with coronary artery disease: Early results of a prospective comparison with conventional ICD outcomes
    • Forleo GB, Tesauro M, Panattoni G, Della Rocca DG, Papavasileiou LP, Sergi D, Di Molfetta A, Santini L, Romeo F. Impact of continuous intracardiac ST-segment monitoring on mid-term outcomes of ICD-implanted patients with coronary artery disease: Early results of a prospective comparison with conventional ICD outcomes. Heart. 2012;98:402-407.
    • (2012) Heart. , vol.98 , pp. 402-407
    • Forleo, G.B.1    Tesauro, M.2    Panattoni, G.3    Della Rocca, D.G.4    Papavasileiou, L.P.5    Sergi, D.6    Di Molfetta, A.7    Santini, L.8    Romeo, F.9
  • 57
    • 23844525145 scopus 로고    scopus 로고
    • Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization
    • Yu CM, Wang L, Chau E, Chan RH, Kong SL, Tang MO, Christensen J, Stadler RW, Lau CP. Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation. 2005;112:841-848.
    • (2005) Circulation. , vol.112 , pp. 841-848
    • Yu, C.M.1    Wang, L.2    Chau, E.3    Chan, R.H.4    Kong, S.L.5    Tang, M.O.6    Christensen, J.7    Stadler, R.W.8    Lau, C.P.9
  • 62
    • 16644394121 scopus 로고    scopus 로고
    • Closed loop stimulation in prevention of vasovagal syncope: Inotropy controlled pacing in vasovagal syncope (INVASY): A multicentre randomized, single blind, controlled study
    • INVASY Study Investigators.
    • Occhetta E, Bortnik M, Audoglio R, Vassanelli C; INVASY Study Investigators. Closed loop stimulation in prevention of vasovagal syncope: Inotropy Controlled Pacing in Vasovagal Syncope (INVASY): A multicentre randomized, single blind, controlled study. Europace. 2004;6:538-547.
    • (2004) Europace. , vol.6 , pp. 538-547
    • Occhetta, E.1    Bortnik, M.2    Audoglio, R.3    Vassanelli, C.4
  • 63
    • 0034930013 scopus 로고    scopus 로고
    • Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: Results of a 1 year multicentre feasibility study
    • Ohlsson A, Kubo SH, Steinhaus D, Connelly DT, Adler S, Bitkover C, Nordlander R, Rydén L, Bennett T. Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: Results of a 1 year multicentre feasibility study. Eur Heart J. 2001;22:942-954.
    • (2001) Eur Heart J. , vol.22 , pp. 942-954
    • Ohlsson, A.1    Kubo, S.H.2    Steinhaus, D.3    Connelly, D.T.4    Adler, S.5    Bitkover, C.6    Nordlander, R.7    Rydén, L.8    Bennett, T.9
  • 64
    • 45849110223 scopus 로고    scopus 로고
    • Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: Early clinical results
    • Delnoy PP, Marcelli E, Oudeluttikhuis H, Nicastia D, Renesto F, Cercenelli L, Plicchi G. Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: Early clinical results. Europace. 2008;10:801-808.
    • (2008) Europace. , vol.10 , pp. 801-808
    • Delnoy, P.P.1    Marcelli, E.2    Oudeluttikhuis, H.3    Nicastia, D.4    Renesto, F.5    Cercenelli, L.6    Plicchi, G.7
  • 71
    • 77950884226 scopus 로고    scopus 로고
    • Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: Results from partners hf (program to access and review trending information and evaluate correlation to symptoms in patients with heart failure) study
    • PARTNERS Study Investigators.
    • Whellan DJ, Ousdigian KT, Al-Khatib SM, Pu W, Sarkar S, Porter CB, Pavri BB, OConnor CM; PARTNERS Study Investigators. Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: Results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) study. J Am Coll Cardiol. 2010;55:1803-1810.
    • (2010) J Am Coll Cardiol. , vol.55 , pp. 1803-1810
    • Whellan, D.J.1    Ousdigian, K.T.2    Al-Khatib, S.M.3    Pu, W.4    Sarkar, S.5    Porter, C.B.6    Pavri, B.B.7    Oconnor, C.M.8
  • 73
    • 77958471629 scopus 로고    scopus 로고
    • Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: A prospective study
    • Swerdlow CD, Gunderson BD, Ousdigian KT, Abeyratne A, Sachanandani H, Ellenbogen KA. Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: A prospective study. Circulation. 2010;122:1449-1455.
    • (2010) Circulation. , vol.122 , pp. 1449-1455
    • Swerdlow, C.D.1    Gunderson, B.D.2    Ousdigian, K.T.3    Abeyratne, A.4    Sachanandani, H.5    Ellenbogen, K.A.6
  • 74
    • 84862519332 scopus 로고    scopus 로고
    • Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators: The evolution of management strategies of heart failure patients with implantable defibrillators (evolvo) study
    • Landolina M, Perego GB, Lunati M, Curnis A, Guenzati G, Vicentini A, Parati G, Borghi G, Zanaboni P, Valsecchi S, Marzegalli M. Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators: The Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study. Circulation. 2012;125:2985-2992.
    • (2012) Circulation. , vol.125 , pp. 2985-2992
    • Landolina, M.1    Perego, G.B.2    Lunati, M.3    Curnis, A.4    Guenzati, G.5    Vicentini, A.6    Parati, G.7    Borghi, G.8    Zanaboni, P.9    Valsecchi, S.10    Marzegalli, M.11
  • 75
    • 77955171126 scopus 로고    scopus 로고
    • Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The lumos-t safely reduces routine office device follow-up (TRUST) trial
    • TRUST Investigators.
    • Varma N, Epstein AE, Irimpen A, Schweikert R, Love C; TRUST Investigators. Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial. Circulation. 2010;122:325-332.
    • (2010) Circulation. , vol.122 , pp. 325-332
    • Varma, N.1    Epstein, A.E.2    Irimpen, A.3    Schweikert, R.4    Love, C.5
  • 77
    • 68949108703 scopus 로고    scopus 로고
    • Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort: The IMPACT study
    • IMPACT Investigators. e1
    • Ip J, Waldo AL, Lip GY, Rothwell PM, Martin DT, Bersohn MM, Choucair WK, Akar JG, Wathen MS, Rohani P, Halperin JL; IMPACT Investigators. Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort: The IMPACT study. Am Heart J. 2009;158:364-370.e1.
    • (2009) Am Heart J. , vol.158 , pp. 364-370
    • Ip, J.1    Waldo, A.L.2    Lip, G.Y.3    Rothwell, P.M.4    Martin, D.T.5    Bersohn, M.M.6    Choucair, W.K.7    Akar, J.G.8    Wathen, M.S.9    Rohani, P.10    Halperin, J.L.11
  • 78
    • 84873463815 scopus 로고    scopus 로고
    • Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): A prospective, multicenter study
    • Verma A, Champagne J, Sapp J, Essebag V, Novak P, Skanes A, Morillo CA, Khaykin Y, Birnie D. Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): A prospective, multicenter study. JAMA Intern Med. 2013;173:149-156.
    • (2013) JAMA Intern Med. , vol.173 , pp. 149-156
    • Verma, A.1    Champagne, J.2    Sapp, J.3    Essebag, V.4    Novak, P.5    Skanes, A.6    Morillo, C.A.7    Khaykin, Y.8    Birnie, D.9
  • 79
    • 84878947462 scopus 로고    scopus 로고
    • Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke
    • Cotter PE, Martin PJ, Ring L, Warburton EA, Belham M, Pugh PJ. Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke. Neurology. 2013;80:1546-1550.
    • (2013) Neurology. , vol.80 , pp. 1546-1550
    • Cotter, P.E.1    Martin, P.J.2    Ring, L.3    Warburton, E.A.4    Belham, M.5    Pugh, P.J.6
  • 80
    • 77951896083 scopus 로고    scopus 로고
    • Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial
    • XPECT Trial Investigators.
    • Hindricks G, Pokushalov E, Urban L, Taborsky M, Kuck KH, Lebedev D, Rieger G, Pürerfellner H; XPECT Trial Investigators. Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial. Circ Arrhythm Electrophysiol. 2010;3:141-147.
    • (2010) Circ Arrhythm Electrophysiol. , vol.3 , pp. 141-147
    • Hindricks, G.1    Pokushalov, E.2    Urban, L.3    Taborsky, M.4    Kuck, K.H.5    Lebedev, D.6    Rieger, G.7    Pürerfellner, H.8
  • 81
    • 77957974487 scopus 로고    scopus 로고
    • Long-term recording of cardiac arrhythmias with an implantable cardiac monitor in patients with reduced ejection fraction after acute myocardial infarction: The cardiac arrhythmias and risk stratification after acute myocardial infarction (carisma) study
    • Cardiac Arrhythmias and Risk Stratification After Acute Myocardial Infarction (CARISMA) Study Group.
    • Bloch Thomsen PE, Jons C, Raatikainen MJ, Moerch Joergensen R, Hartikainen J, Virtanen V, Boland J, Anttonen O, Gang UJ, Hoest N, Boersma LV, Platou ES, Becker D, Messier MD, Huikuri HV; Cardiac Arrhythmias and Risk Stratification After Acute Myocardial Infarction (CARISMA) Study Group. Long-term recording of cardiac arrhythmias with an implantable cardiac monitor in patients with reduced ejection fraction after acute myocardial infarction: The Cardiac Arrhythmias and Risk Stratification After Acute Myocardial Infarction (CARISMA) study. Circulation. 2010;122:1258-1264.
    • (2010) Circulation. , vol.122 , pp. 1258-1264
    • Bloch Thomsen, P.E.1    Jons, C.2    Raatikainen, M.J.3    Moerch Joergensen, R.4    Hartikainen, J.5    Virtanen, V.6    Boland, J.7    Anttonen, O.8    Gang, U.J.9    Hoest, N.10    Boersma, L.V.11    Platou, E.S.12    Becker, D.13    Messier, M.D.14    Huikuri, H.V.15
  • 82
    • 84857630952 scopus 로고    scopus 로고
    • Treating cardiac arrhythmias detected with an implantable cardiac monitor in patients after an acute myocardial infarction
    • Jons C, Thomsen PE. Treating cardiac arrhythmias detected with an implantable cardiac monitor in patients after an acute myocardial infarction. Curr Treat Options Cardiovasc Med. 2012;14:39-49.
    • (2012) Curr Treat Options Cardiovasc Med. , vol.14 , pp. 39-49
    • Jons, C.1    Thomsen, P.E.2
  • 83
    • 0035816618 scopus 로고    scopus 로고
    • HCN2 overexpression in newborn and adult ventricular myocytes: Distinct effects on gating and excitability
    • Qu J, Barbuti A, Protas L, Santoro B, Cohen IS, Robinson RB. HCN2 overexpression in newborn and adult ventricular myocytes: Distinct effects on gating and excitability. Circ Res. 2001;89:E8-E14.
    • (2001) Circ Res. , vol.89 , pp. 8-14
    • Qu, J.1    Barbuti, A.2    Protas, L.3    Santoro, B.4    Cohen, I.S.5    Robinson, R.B.6
  • 84
    • 0037469231 scopus 로고    scopus 로고
    • Dominant-negative suppression of HCN channels markedly reduces the native pacemaker current I(f) and undermines spontaneous beating of neonatal cardiomyocytes
    • Er F, Larbig R, Ludwig A, Biel M, Hofmann F, Beuckelmann DJ, Hoppe UC. Dominant-negative suppression of HCN channels markedly reduces the native pacemaker current I(f) and undermines spontaneous beating of neonatal cardiomyocytes. Circulation. 2003;107:485-489.
    • (2003) Circulation. , vol.107 , pp. 485-489
    • Er, F.1    Larbig, R.2    Ludwig, A.3    Biel, M.4    Hofmann, F.5    Beuckelmann, D.J.6    Hoppe, U.C.7
  • 86
    • 33748508208 scopus 로고    scopus 로고
    • Bioartificial sinus node constructed via in vivo gene transfer of an engineered pacemaker HCN Channel reduces the dependence on electronic pacemaker in a sick-sinus syndrome model
    • Tse HF, Xue T, Lau CP, Siu CW, Wang K, Zhang QY, Tomaselli GF, Akar FG, Li RA. Bioartificial sinus node constructed via in vivo gene transfer of an engineered pacemaker HCN Channel reduces the dependence on electronic pacemaker in a sick-sinus syndrome model. Circulation. 2006;114:1000-1011.
    • (2006) Circulation. , vol.114 , pp. 1000-1011
    • Tse, H.F.1    Xue, T.2    Lau, C.P.3    Siu, C.W.4    Wang, K.5    Zhang, Q.Y.6    Tomaselli, G.F.7    Akar, F.G.8    Li, R.A.9
  • 88
    • 84872192083 scopus 로고    scopus 로고
    • Direct conversion of quiescent cardiomyocytes to pacemaker cells by expression of Tbx18
    • Kapoor N, Liang W, Marbán E, Cho HC. Direct conversion of quiescent cardiomyocytes to pacemaker cells by expression of Tbx18. Nat Biotechnol. 2013;31:54-62.
    • (2013) Nat Biotechnol. , vol.31 , pp. 54-62
    • Kapoor, N.1    Liang, W.2    Marbán, E.3    Cho, H.C.4
  • 90
    • 67650531390 scopus 로고    scopus 로고
    • Sympathetic nervous system activation in human heart failure: Clinical implications of an updated model
    • Floras JS. Sympathetic nervous system activation in human heart failure: Clinical implications of an updated model. J Am Coll Cardiol. 2009;54:375-385.
    • (2009) J Am Coll Cardiol. , vol.54 , pp. 375-385
    • Floras, J.S.1
  • 91
    • 53749090260 scopus 로고    scopus 로고
    • Parasympathetic nervous system and heart failure: Pathophysiology and potential implications for therapy
    • Olshansky B, Sabbah HN, Hauptman PJ, Colucci WS. Parasympathetic nervous system and heart failure: Pathophysiology and potential implications for therapy. Circulation. 2008;118:863-871.
    • (2008) Circulation. , vol.118 , pp. 863-871
    • Olshansky, B.1    Sabbah, H.N.2    Hauptman, P.J.3    Colucci, W.S.4
  • 92
    • 84869170387 scopus 로고    scopus 로고
    • Vagal stimulation for the treatment of heart failure: A translational success story
    • Schwartz PJ. Vagal stimulation for the treatment of heart failure: A translational success story. Heart. 2012;98:1687-1689.
    • (2012) Heart. , vol.98 , pp. 1687-1689
    • Schwartz, P.J.1
  • 95
    • 79951594692 scopus 로고    scopus 로고
    • Rheos: An implantable carotid sinus stimulation device for the nonpharmacologic treatment of resistant hypertension
    • Ng MM, Sica DA, Frishman WH. Rheos: An implantable carotid sinus stimulation device for the nonpharmacologic treatment of resistant hypertension. Cardiol Rev. 2011;19:52-57.
    • (2011) Cardiol Rev. , vol.19 , pp. 52-57
    • Ng, M.M.1    Sica, D.A.2    Frishman, W.H.3
  • 97
    • 21044457259 scopus 로고    scopus 로고
    • Thoracic spinal cord stimulation reduces the risk of ischemic ventricular arrhythmias in a postinfarction heart failure canine model
    • Issa ZF, Zhou X, Ujhelyi MR, Rosenberger J, Bhakta D, Groh WJ, Miller JM, Zipes DP. Thoracic spinal cord stimulation reduces the risk of ischemic ventricular arrhythmias in a postinfarction heart failure canine model. Circulation. 2005;111:3217-3220.
    • (2005) Circulation. , vol.111 , pp. 3217-3220
    • Issa, Z.F.1    Zhou, X.2    Ujhelyi, M.R.3    Rosenberger, J.4    Bhakta, D.5    Groh, W.J.6    Miller, J.M.7    Zipes, D.P.8
  • 99


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.