Volumn 39, Issue 3, 2014, Pages 567-575

Effect of echo-sampling strategy on the accuracy of out-of-phase and in-phase multiecho gradient-Echo MRI hepatic fat fraction estimation

Author keywords

fat quantification; fatty liver disease; hepatic steatosis; magnetic resonance; multiecho

Indexed keywords

ADIPOSE TISSUE; ADOLESCENT; ADULT; CHILD; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; CROSS-SECTIONAL STUDY; ECHO PLANAR IMAGING; FATTY LIVER; FEMALE; HUMAN; MALE; METABOLISM; MIDDLE AGED; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PATHOLOGY; PROCEDURES; PROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; STATISTICAL MODEL; YOUNG ADULT;

EID: 84894228448     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24193     Document Type: Article
Times cited : (20)

References (13)
  • 1
    • 40249090380 scopus 로고    scopus 로고
    • Relaxation effects in the quantification of fat using gradient echo imaging
    • Bydder M, Yokoo T, Hamilton G, et al. Relaxation effects in the quantification of fat using gradient echo imaging. Magn Reson Imaging 2008; 26: 347-359.
    • (2008) Magn Reson Imaging , vol.26 , pp. 347-359
    • Bydder, M.1    Yokoo, T.2    Hamilton, G.3
  • 2
    • 64949095273 scopus 로고    scopus 로고
    • Nonalcoholic fatty liver disease: Diagnostic and fat-grading accuracy of low-flip-angle multiecho gradient-recalled-echo MR imaging at 1.5 T
    • Yokoo T, Bydder M, Hamilton G, et al. Nonalcoholic fatty liver disease: diagnostic and fat-grading accuracy of low-flip-angle multiecho gradient-recalled-echo MR imaging at 1.5 T. Radiology 2009; 251: 67-76.
    • (2009) Radiology , vol.251 , pp. 67-76
    • Yokoo, T.1    Bydder, M.2    Hamilton, G.3
  • 3
    • 79952309399 scopus 로고    scopus 로고
    • Estimation of hepatic proton-density fat fraction by using MR imaging at 3.0 T
    • Yokoo T, Shiehmorteza M, Hamilton G, et al. Estimation of hepatic proton-density fat fraction by using MR imaging at 3.0 T. Radiology 2011; 258: 749-759.
    • (2011) Radiology , vol.258 , pp. 749-759
    • Yokoo, T.1    Shiehmorteza, M.2    Hamilton, G.3
  • 4
    • 0035579044 scopus 로고    scopus 로고
    • In vivo detection and quantification of scalar coupled 1H NMR resonances
    • DeGraff R, Rothman D,. In vivo detection and quantification of scalar coupled 1H NMR resonances. Concepts Magn Reson 2001; 13: 32-76.
    • (2001) Concepts Magn Reson , vol.13 , pp. 32-76
    • Degraff, R.1    Rothman, D.2
  • 6
    • 0035033455 scopus 로고    scopus 로고
    • Java-based graphical user interface for MRUI, a software package for quantitation of in vivo/medical magnetic resonance spectroscopy signals
    • Naressi A, Couturier C, Castang I, de Beer R, Graveron-Demilly D,. Java-based graphical user interface for MRUI, a software package for quantitation of in vivo/medical magnetic resonance spectroscopy signals. Comput Biol Med 2001; 31: 269-286.
    • (2001) Comput Biol Med , vol.31 , pp. 269-286
    • Naressi, A.1    Couturier, C.2    Castang, I.3    De Beer, R.4    Graveron-Demilly, D.5
  • 7
    • 67650091408 scopus 로고    scopus 로고
    • Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification
    • Hamilton G, Middleton MS, Bydder M, et al. Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification. J Magn Reson Imaging 2009; 30: 145-152.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 145-152
    • Hamilton, G.1    Middleton, M.S.2    Bydder, M.3
  • 8
    • 80051586308 scopus 로고    scopus 로고
    • In vivo characterization of the liver fat (1)H MR spectrum
    • Hamilton G, Yokoo T, Bydder M, et al. In vivo characterization of the liver fat (1)H MR spectrum. NMR Biomed 2011; 24: 784-790.
    • (2011) NMR Biomed , vol.24 , pp. 784-790
    • Hamilton, G.1    Yokoo, T.2    Bydder, M.3
  • 9
    • 84923818429 scopus 로고
    • Better bootstrap confidence intervals (with discussion)
    • Efron B,. Better bootstrap confidence intervals (with discussion). J Am Stat Assoc 1987; 82: 171-200.
    • (1987) J Am Stat Assoc , vol.82 , pp. 171-200
    • Efron, B.1
  • 11
    • 0033007207 scopus 로고    scopus 로고
    • Measurement of intracellular triglyceride stores by H spectroscopy: Validation in vivo
    • Szczepaniak LS, Babcock EE, Schick F, et al. Measurement of intracellular triglyceride stores by H spectroscopy: validation in vivo. Am J Physiol 1999; 276 (5 Pt 1): E977-989.
    • (1999) Am J Physiol , vol.276 , Issue.5 PART 1
    • Szczepaniak, L.S.1    Babcock, E.E.2    Schick, F.3
  • 13
    • 55749085613 scopus 로고    scopus 로고
    • Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling
    • Yu H, Shimakawa A, McKenzie CA, Brodsky E, Brittain JH, Reeder SB,. Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling. Magn Reson Med 2008; 60: 1122-1134.
    • (2008) Magn Reson Med , vol.60 , pp. 1122-1134
    • Yu, H.1    Shimakawa, A.2    McKenzie, C.A.3    Brodsky, E.4    Brittain, J.H.5    Reeder, S.B.6