-
1
-
-
40549127018
-
Reference intervals for serum creatinine concentrations: assessment of available data for global application
-
Ceriotti F., Boyd J.C., Klein G., et al. Reference intervals for serum creatinine concentrations: assessment of available data for global application. Clin Chem 2008, 54:559-566.
-
(2008)
Clin Chem
, vol.54
, pp. 559-566
-
-
Ceriotti, F.1
Boyd, J.C.2
Klein, G.3
-
3
-
-
79953788682
-
Creatinine determination according to Jaffe - what does it stand for?
-
Delanghe J.R., Speeckaert M. Creatinine determination according to Jaffe - what does it stand for?. NDT Plus 2011, 1-4.
-
(2011)
NDT Plus
, pp. 1-4
-
-
Delanghe, J.R.1
Speeckaert, M.2
-
4
-
-
77953516542
-
Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods
-
Srisawasdi P., Chaichanajarernkul U., Teerakanjana N., Vanavanan S., Kroll M.H. Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods. J Clin Lab Anal 2010, 24:123-133.
-
(2010)
J Clin Lab Anal
, vol.24
, pp. 123-133
-
-
Srisawasdi, P.1
Chaichanajarernkul, U.2
Teerakanjana, N.3
Vanavanan, S.4
Kroll, M.H.5
-
5
-
-
33747821308
-
The effect of bilirubin on reaction rate methods for the measurement of creatinine
-
Soldin L., Henderson L., Hill J.G. The effect of bilirubin on reaction rate methods for the measurement of creatinine. Clin Chem 1977, 23:1141.
-
(1977)
Clin Chem
, vol.23
, pp. 1141
-
-
Soldin, L.1
Henderson, L.2
Hill, J.G.3
-
6
-
-
0003215487
-
Interesting interferences in a direct serum creatinine reaction
-
Watkins R.E., Feldkamp C.S., Thibert R.J., Zak B. Interesting interferences in a direct serum creatinine reaction. Microchem J 1976, 21:370-384.
-
(1976)
Microchem J
, vol.21
, pp. 370-384
-
-
Watkins, R.E.1
Feldkamp, C.S.2
Thibert, R.J.3
Zak, B.4
-
7
-
-
0017933989
-
Bilirubin interference with the kinetic Jaffe method for serum creatinine
-
Daugherty N.A., Hammond K.B., Osberg I.M. Bilirubin interference with the kinetic Jaffe method for serum creatinine. Clin Chem 1978, 24:392-393.
-
(1978)
Clin Chem
, vol.24
, pp. 392-393
-
-
Daugherty, N.A.1
Hammond, K.B.2
Osberg, I.M.3
-
8
-
-
0023095673
-
Investigation into negative interference by jaundiced plasma in kinetic Jaffe methods for plasma creatinine determination
-
Knapp M.L., Hadid O. Investigation into negative interference by jaundiced plasma in kinetic Jaffe methods for plasma creatinine determination. Ann Clin Biochem 1987, 24:85-97.
-
(1987)
Ann Clin Biochem
, vol.24
, pp. 85-97
-
-
Knapp, M.L.1
Hadid, O.2
-
9
-
-
84857581485
-
Limitations of compensated Jaffe creatinine assays in cirrhotic patients
-
Kuster N., Bargnoux A.S., Pageaux G.P., Cristol J.P. Limitations of compensated Jaffe creatinine assays in cirrhotic patients. Clin Biochem 2012, 45:320-325.
-
(2012)
Clin Biochem
, vol.45
, pp. 320-325
-
-
Kuster, N.1
Bargnoux, A.S.2
Pageaux, G.P.3
Cristol, J.P.4
-
10
-
-
0020619146
-
Enzymic creatinine assay: a new colorimetric method based on hydrogen peroxide measurement
-
Fossati P., Prencipe L., Berti G. Enzymic creatinine assay: a new colorimetric method based on hydrogen peroxide measurement. Clin Chem 1983, 29:1494-1496.
-
(1983)
Clin Chem
, vol.29
, pp. 1494-1496
-
-
Fossati, P.1
Prencipe, L.2
Berti, G.3
-
11
-
-
44949254207
-
Enzymatic assays for creatinine: time for action
-
Panteghini M. Enzymatic assays for creatinine: time for action. Clin Chem Lab Med 2008, 46:567-572.
-
(2008)
Clin Chem Lab Med
, vol.46
, pp. 567-572
-
-
Panteghini, M.1
-
12
-
-
84856402033
-
Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles
-
Greenberg N., Roberts W.L., Bachmann L.M., et al. Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles. Clin Chem 2012, 58:391-401.
-
(2012)
Clin Chem
, vol.58
, pp. 391-401
-
-
Greenberg, N.1
Roberts, W.L.2
Bachmann, L.M.3
-
13
-
-
29744469415
-
Recommendations for improving serum creatinine measurement: a report from the laboratory working group of the National Kidney Disease Education Program
-
Myers G.L., Miller W.G., Coresh J., et al. Recommendations for improving serum creatinine measurement: a report from the laboratory working group of the National Kidney Disease Education Program. Clin Chem 2006, 52:5-18.
-
(2006)
Clin Chem
, vol.52
, pp. 5-18
-
-
Myers, G.L.1
Miller, W.G.2
Coresh, J.3
-
14
-
-
84861232586
-
An international assessment of the metrological equivalence of higher-order measurement services for creatinine in serum
-
Camara J., Lippa K.A., Duewer D.L., Gasca-Aragon H., Toman B. An international assessment of the metrological equivalence of higher-order measurement services for creatinine in serum. Anal Bioanal Chem 2012, 403:527-535.
-
(2012)
Anal Bioanal Chem
, vol.403
, pp. 527-535
-
-
Camara, J.1
Lippa, K.A.2
Duewer, D.L.3
Gasca-Aragon, H.4
Toman, B.5
-
16
-
-
0017698765
-
Mass fragmentography of creatinine proposed as a reference method
-
Björkhem I., Blomstrand R., Öhman G. Mass fragmentography of creatinine proposed as a reference method. Clin Chem 1977, 23:2114-2121.
-
(1977)
Clin Chem
, vol.23
, pp. 2114-2121
-
-
Björkhem, I.1
Blomstrand, R.2
Öhman, G.3
-
17
-
-
84945018793
-
Measurement of creatinine in human serum by isotope dilution mass spectrometry
-
Siekmann L. Measurement of creatinine in human serum by isotope dilution mass spectrometry. J Clin Chem Clin Biochem 1985, 23:137-144.
-
(1985)
J Clin Chem Clin Biochem
, vol.23
, pp. 137-144
-
-
Siekmann, L.1
-
18
-
-
0022750054
-
Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method
-
Welch M.J., Cohen A., Hertz H.S., et al. Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method. Anal Chem 1986, 58:1681-1865.
-
(1986)
Anal Chem
, vol.58
, pp. 1681-1865
-
-
Welch, M.J.1
Cohen, A.2
Hertz, H.S.3
-
19
-
-
0027263203
-
Candidate reference methods for determining target values for cholesterol, creatinine, uric acid and glucose in external quality assessment and internal accuracy control. I. Method setup
-
Stöckl D., Reinauer H. Candidate reference methods for determining target values for cholesterol, creatinine, uric acid and glucose in external quality assessment and internal accuracy control. I. Method setup. Clin Chem 1993, 39:993-1000.
-
(1993)
Clin Chem
, vol.39
, pp. 993-1000
-
-
Stöckl, D.1
Reinauer, H.2
-
20
-
-
0042347707
-
Development of a liquid chromatography-mass spectrometry method for the high-accuracy determination of creatinine in serum
-
Stokes P., O'Connor G. Development of a liquid chromatography-mass spectrometry method for the high-accuracy determination of creatinine in serum. J Chromatogr B 2003, 794:125-136.
-
(2003)
J Chromatogr B
, vol.794
, pp. 125-136
-
-
Stokes, P.1
O'Connor, G.2
-
21
-
-
34548321006
-
Certification of creatinine in a human serum reference material by GC-MS and LC-MS
-
Dodder N.G., Tai S.S.C., Sniegoski L.T., Zhang N.F., Welch M.J. Certification of creatinine in a human serum reference material by GC-MS and LC-MS. Clin Chem 2007, 53:1694-1699.
-
(2007)
Clin Chem
, vol.53
, pp. 1694-1699
-
-
Dodder, N.G.1
Tai, S.S.C.2
Sniegoski, L.T.3
Zhang, N.F.4
Welch, M.J.5
-
22
-
-
77956173033
-
Development and validation of a rapid liquid chromatography isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for serum creatinine
-
Hétu P.O., Gingras M.E., Vinet B. Development and validation of a rapid liquid chromatography isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for serum creatinine. Clin Biochem 2010, 43:1158-1162.
-
(2010)
Clin Biochem
, vol.43
, pp. 1158-1162
-
-
Hétu, P.O.1
Gingras, M.E.2
Vinet, B.3
-
24
-
-
77951580545
-
Evaluation of minimal labelling for stable isotope dilution in organic analysis
-
González-Antuña A., Rodríguez-González P., Centineo G., García Alonso J.I. Evaluation of minimal labelling for stable isotope dilution in organic analysis. Analyst 2010, 135:953-964.
-
(2010)
Analyst
, vol.135
, pp. 953-964
-
-
González-Antuña, A.1
Rodríguez-González, P.2
Centineo, G.3
García Alonso, J.I.4
-
25
-
-
84858698239
-
Development of a routine method for the simultaneous confirmation and determination of clenbuterol in urine by minimal labeling isotope pattern deconvolution and GC-EI-MS
-
González-Antuña A., Rodríguez-González P., Lavandera I., Centineo G., Gotor V., García Alonso J.I. Development of a routine method for the simultaneous confirmation and determination of clenbuterol in urine by minimal labeling isotope pattern deconvolution and GC-EI-MS. Anal Bioanal Chem 2012, 402:1879-1888.
-
(2012)
Anal Bioanal Chem
, vol.402
, pp. 1879-1888
-
-
González-Antuña, A.1
Rodríguez-González, P.2
Lavandera, I.3
Centineo, G.4
Gotor, V.5
García Alonso, J.I.6
-
26
-
-
27644463671
-
Analysis of creatine, creatinine, creatine-d3 and creatinine-d3 in urine, plasma, and red blood cells by HPLC and GC-MS to follow the fate of ingested creatine-d3
-
MacNeil L., Hill L., MacDonald D., et al. Analysis of creatine, creatinine, creatine-d3 and creatinine-d3 in urine, plasma, and red blood cells by HPLC and GC-MS to follow the fate of ingested creatine-d3. J Chromatogr B 2005, 827:210-215.
-
(2005)
J Chromatogr B
, vol.827
, pp. 210-215
-
-
MacNeil, L.1
Hill, L.2
MacDonald, D.3
-
27
-
-
1942537109
-
Using solid-phase microextraction gas chromatography-mass spectrometry and high performance liquid chromatography with fluorescence detection to analyze fluorescent derivatives of the biogenic amines creatine and creatinine
-
Whitehead T.L., Holmes W.E., Flores B.J., Leidensdorf J.W. Using solid-phase microextraction gas chromatography-mass spectrometry and high performance liquid chromatography with fluorescence detection to analyze fluorescent derivatives of the biogenic amines creatine and creatinine. Spectrosc Lett 2004, 37:95-103.
-
(2004)
Spectrosc Lett
, vol.37
, pp. 95-103
-
-
Whitehead, T.L.1
Holmes, W.E.2
Flores, B.J.3
Leidensdorf, J.W.4
-
28
-
-
2342625386
-
Deconvolution of isobaric interferences in mass spectra
-
Mejia J., Caruso J.A. Deconvolution of isobaric interferences in mass spectra. J Am Soc Mass Spectrom 2004, 15:654-658.
-
(2004)
J Am Soc Mass Spectrom
, vol.15
, pp. 654-658
-
-
Mejia, J.1
Caruso, J.A.2
-
30
-
-
84894090237
-
-
Spanish Society of Clinical Biochemistry and Molecular Pathology [Accessed: 4 June 2013]
-
Spanish Society of Clinical Biochemistry and Molecular Pathology [Accessed: 4 June 2013]. http://www.seqc.es/es/Sociedad/7/51/102/Base_de_datos_de_Variacion_biologica_Bases_de_datos_y_documentos_del_Comite_de_Garantia_de_la_Calidad_y_Acreditacion_Comite_de_Garantia_de_la_Calidad_y_Acreditacion_/.
-
-
-
-
31
-
-
37049080642
-
Calculating standard deviations and confidence intervals with a universally applicable spreadsheet technique
-
Kragten J. Calculating standard deviations and confidence intervals with a universally applicable spreadsheet technique. Analyst 1994, 119:2161-2165.
-
(1994)
Analyst
, vol.119
, pp. 2161-2165
-
-
Kragten, J.1
-
33
-
-
69849088055
-
Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis
-
Stöckl D., Sluss P.M., Thienpont L.M. Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis. Clin Chim Acta 2009, 408:8-13.
-
(2009)
Clin Chim Acta
, vol.408
, pp. 8-13
-
-
Stöckl, D.1
Sluss, P.M.2
Thienpont, L.M.3
-
34
-
-
33644696674
-
Validation of a liquid chromatography tandem mass spectrometry for serum creatinine and comparison with enzymatic and Jaffe methods
-
Owen L.J., Wear J.E., Keevil B.G. Validation of a liquid chromatography tandem mass spectrometry for serum creatinine and comparison with enzymatic and Jaffe methods. Ann Clin Biochem 2006, 43:118-123.
-
(2006)
Ann Clin Biochem
, vol.43
, pp. 118-123
-
-
Owen, L.J.1
Wear, J.E.2
Keevil, B.G.3
-
35
-
-
33750134688
-
Does the ID-MS traceable MDRD equation work and is it suitable for use with compensated Jaffe and enzymatic creatinine assays?
-
Vickery S., Stevens P.E., Dalton R.N., Van Lente F., Lamb E.J. Does the ID-MS traceable MDRD equation work and is it suitable for use with compensated Jaffe and enzymatic creatinine assays?. Nephrol Dial Transplant 2006, 21:2439-2445.
-
(2006)
Nephrol Dial Transplant
, vol.21
, pp. 2439-2445
-
-
Vickery, S.1
Stevens, P.E.2
Dalton, R.N.3
Van Lente, F.4
Lamb, E.J.5
-
36
-
-
84875262891
-
Enzymatic but not compensated Jaffe methods reach the desirable specifications of NKDEP at normal levels of creatinine. Results of the French multicentric evaluation
-
Boutten A., Bargnoux A.S., Carlier M.C., et al. Enzymatic but not compensated Jaffe methods reach the desirable specifications of NKDEP at normal levels of creatinine. Results of the French multicentric evaluation. Clin Chim Acta 2013, 419:123-135.
-
(2013)
Clin Chim Acta
, vol.419
, pp. 123-135
-
-
Boutten, A.1
Bargnoux, A.S.2
Carlier, M.C.3
-
37
-
-
84867055649
-
Clinical evaluation of analytical variations in serum creatinine measurements: why laboratories should abandon Jaffe techniques
-
Drion I., Cobbaert C.F., Groenier K.H., et al. Clinical evaluation of analytical variations in serum creatinine measurements: why laboratories should abandon Jaffe techniques. Nephrology 2012, 13:133-140.
-
(2012)
Nephrology
, vol.13
, pp. 133-140
-
-
Drion, I.1
Cobbaert, C.F.2
Groenier, K.H.3
-
38
-
-
33847352503
-
Does bilirubin cause interference in Roche creatinine methods?
-
[Letter]
-
Owen L.J., Keevil B.G. Does bilirubin cause interference in Roche creatinine methods?. Clin Chem 2007, 53:370-371. [Letter].
-
(2007)
Clin Chem
, vol.53
, pp. 370-371
-
-
Owen, L.J.1
Keevil, B.G.2
-
39
-
-
79959295985
-
Evaluation of the interference of haemoglobin, bilirubin and lipids on Roche Cobas 6000 assays
-
Ji J.Z., Meng Q.H. Evaluation of the interference of haemoglobin, bilirubin and lipids on Roche Cobas 6000 assays. Clin Chim Acta 2011, 412:1550-1553.
-
(2011)
Clin Chim Acta
, vol.412
, pp. 1550-1553
-
-
Ji, J.Z.1
Meng, Q.H.2
-
40
-
-
41649103542
-
Extent of bilirubin interference with Beckman creatinine methods
-
Dimeski G., McWhinney B., Jones B., Mason R., Carter A. Extent of bilirubin interference with Beckman creatinine methods. Ann Clin Biochem 2008, 45:91-92.
-
(2008)
Ann Clin Biochem
, vol.45
, pp. 91-92
-
-
Dimeski, G.1
McWhinney, B.2
Jones, B.3
Mason, R.4
Carter, A.5
-
41
-
-
62149102286
-
Prime time for enzymatic creatinine methods in paediatrics
-
Cobbaert C.M., Baadenhuijsen H., Weykamp C.W. Prime time for enzymatic creatinine methods in paediatrics. Clin Chem 2009, 55:549-558.
-
(2009)
Clin Chem
, vol.55
, pp. 549-558
-
-
Cobbaert, C.M.1
Baadenhuijsen, H.2
Weykamp, C.W.3
|