메뉴 건너뛰기




Volumn 31, Issue 2, 2014, Pages 157-162

Accurate automated apnea analysis in preterm infants

Author keywords

apnea of prematurity; medical record; newborn intensive care; patient monitoring

Indexed keywords

ALARM MONITOR; ALGORITHM; APNEA; ARTICLE; AUTOMATION; BRADYCARDIA; BREATHING RATE; HEART RATE; HOSPITAL ADMISSION; HUMAN; MAJOR CLINICAL STUDY; MEDICAL DOCUMENTATION; MEDICAL RECORD REVIEW; MEDICAL SOCIETY; NEWBORN; NEWBORN INTENSIVE CARE; OXYGEN DESATURATION; PREMATURITY; PRIORITY JOURNAL; PULSE OXIMETRY; VERY LOW BIRTH WEIGHT; VITAL SIGN; WAVEFORM;

EID: 84893705677     PISSN: 07351631     EISSN: 10988785     Source Type: Journal    
DOI: 10.1055/s-0033-1343769     Document Type: Article
Times cited : (46)

References (24)
  • 1
    • 33745518762 scopus 로고    scopus 로고
    • Summary proceedings from the apnea-of-prematurity group
    • Finer N. N., Higgins R., Kattwinkel J., Martin R. J. Summary proceedings from the apnea-of-prematurity group. Pediatrics: 2006; 117 3 Pt 2 S47 S51
    • (2006) Pediatrics , vol.117 , Issue.3 PART 2
    • Finer, N.N.1    Higgins, R.2    Kattwinkel, J.3    Martin, R.J.4
  • 2
    • 0020634223 scopus 로고
    • Undetected episodes of prolonged apnea and severe bradycardia in preterm infants
    • Southall D. P., Levitt G. A., Richards J. M., et al. Undetected episodes of prolonged apnea and severe bradycardia in preterm infants. Pediatrics: 1983; 72 541 551
    • (1983) Pediatrics , vol.72 , pp. 541-551
    • Southall, D.P.1    Levitt, G.A.2    Richards, J.M.3
  • 5
    • 0035795604 scopus 로고    scopus 로고
    • Cardiorespiratory events recorded on home monitors: Comparison of healthy infants with those at increased risk for SIDS
    • et al; Collaborative Home Infant Monitoring Evaluation (CHIME) Study Group
    • Ramanathan R., Corwin M. J., Hunt C. E., et al. Collaborative Home Infant Monitoring Evaluation (CHIME) Study Group Cardiorespiratory events recorded on home monitors: Comparison of healthy infants with those at increased risk for SIDS. JAMA: 2001; 285 2199 2207
    • (2001) JAMA , vol.285 , pp. 2199-2207
    • Ramanathan, R.1    Corwin, M.J.2    Hunt, C.E.3
  • 6
    • 0030817872 scopus 로고    scopus 로고
    • Margin of safety for discharge after apnea in preterm infants
    • Darnall R. A., Kattwinkel J., Nattie C., Robinson M. Margin of safety for discharge after apnea in preterm infants. Pediatrics: 1997; 100 795 801
    • (1997) Pediatrics , vol.100 , pp. 795-801
    • Darnall, R.A.1    Kattwinkel, J.2    Nattie, C.3    Robinson, M.4
  • 9
    • 0016836243 scopus 로고
    • The pediatric pneumogram: A new method for detecting and quantitating apnea in infants
    • Stein I. M., Shannon D. C. The pediatric pneumogram: a new method for detecting and quantitating apnea in infants. Pediatrics: 1975; 55 599 603
    • (1975) Pediatrics , vol.55 , pp. 599-603
    • Stein, I.M.1    Shannon, D.C.2
  • 11
    • 84255193355 scopus 로고    scopus 로고
    • A new algorithm for detecting central apnea in neonates
    • Lee H., Rusin C. G., Lake D. E., et al. A new algorithm for detecting central apnea in neonates. Physiol Meas: 2012; 33 1 17
    • (2012) Physiol Meas , vol.33 , pp. 1-17
    • Lee, H.1    Rusin, C.G.2    Lake, D.E.3
  • 12
    • 84859604476 scopus 로고    scopus 로고
    • Breath-by-breath analysis of cardiorespiratory interaction for quantifying developmental maturity in premature infants
    • Clark M. T., Rusin C. G., Hudson J. L., et al. Breath-by-breath analysis of cardiorespiratory interaction for quantifying developmental maturity in premature infants. J Appl Physiol: 2012; 112 859 867
    • (2012) J Appl Physiol , vol.112 , pp. 859-867
    • Clark, M.T.1    Rusin, C.G.2    Hudson, J.L.3
  • 13
    • 80054717078 scopus 로고    scopus 로고
    • Apnea of prematurity: From cause to treatment
    • Zhao J., Gonzalez F., Mu D. Apnea of prematurity: from cause to treatment. Eur J Pediatr: 2011; 170 1097 1105
    • (2011) Eur J Pediatr , vol.170 , pp. 1097-1105
    • Zhao, J.1    Gonzalez, F.2    Mu, D.3
  • 14
    • 0016705179 scopus 로고
    • Apnea of prematurity. Comparative therapeutic effects of cutaneous stimulation and nasal continuous positive airway pressure
    • Kattwinkel J., Nearman H. S., Fanaroff A. A., Katona P. G., Klaus M. H. Apnea of prematurity. Comparative therapeutic effects of cutaneous stimulation and nasal continuous positive airway pressure. J Pediatr: 1975; 86 588 592
    • (1975) J Pediatr , vol.86 , pp. 588-592
    • Kattwinkel, J.1    Nearman, H.S.2    Fanaroff, A.A.3    Katona, P.G.4    Klaus, M.H.5
  • 15
    • 0037385046 scopus 로고    scopus 로고
    • Apnea, sudden infant death syndrome, and home monitoring
    • Committee on Fetus and Newborn. American Academy of Pediatrics
    • Committee on Fetus and Newborn. American Academy of Pediatrics Apnea, sudden infant death syndrome, and home monitoring. Pediatrics: 2003; 111 4 Pt 1 914 917
    • (2003) Pediatrics , vol.111 , Issue.4 PART 1 , pp. 914-917
  • 16
    • 0032414782 scopus 로고    scopus 로고
    • Efficacy of nasal intermittent positive pressure ventilation in treating apnea of prematurity
    • Lin C. H., Wang S. T., Lin Y. J., Yeh T. F. Efficacy of nasal intermittent positive pressure ventilation in treating apnea of prematurity. Pediatr Pulmonol: 1998; 26 349 353
    • (1998) Pediatr Pulmonol , vol.26 , pp. 349-353
    • Lin, C.H.1    Wang, S.T.2    Lin, Y.J.3    Yeh, T.F.4
  • 17
    • 44249102379 scopus 로고    scopus 로고
    • Pathophysiologic mechanisms underlying apnea of prematurity
    • Martin R. J., Abu-Shaweesh J. M., Baird T. M. Pathophysiologic mechanisms underlying apnea of prematurity. NeoReviews.: 2002; 3 59e 65
    • (2002) NeoReviews. , vol.3
    • Martin, R.J.1    Abu-Shaweesh, J.M.2    Baird, T.M.3
  • 18
    • 0022503076 scopus 로고
    • Survey of alarms in an intensive therapy unit
    • O'Carroll T. M. Survey of alarms in an intensive therapy unit. Anaesthesia: 1986; 41 742 744
    • (1986) Anaesthesia , vol.41 , pp. 742-744
    • O'Carroll, T.M.1
  • 19
    • 0028300877 scopus 로고
    • Crying wolf: False alarms in a pediatric intensive care unit
    • Lawless S. T. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med: 1994; 22 981 985
    • (1994) Crit Care Med , vol.22 , pp. 981-985
    • Lawless, S.T.1
  • 20
    • 0030999897 scopus 로고    scopus 로고
    • Poor prognosis for existing monitors in the intensive care unit
    • Tsien C. L., Fackler J. C. Poor prognosis for existing monitors in the intensive care unit. Crit Care Med: 1997; 25 614 619
    • (1997) Crit Care Med , vol.25 , pp. 614-619
    • Tsien, C.L.1    Fackler, J.C.2
  • 22
    • 84862129487 scopus 로고    scopus 로고
    • The helpful or hindering effects of in-hospital patient monitor alarms on nurses: A qualitative analysis
    • Varpio L., Kuziemsky C., Macdonald C., King W. J. The helpful or hindering effects of in-hospital patient monitor alarms on nurses: a qualitative analysis. Comput Inform Nurs: 2012; 30 210 217
    • (2012) Comput Inform Nurs , vol.30 , pp. 210-217
    • Varpio, L.1    Kuziemsky, C.2    Macdonald, C.3    King, W.J.4
  • 23
    • 34047192819 scopus 로고    scopus 로고
    • Nurses' reactions to alarms in a neonatal intensive care unit
    • Bitan Y., Meyer J., Shinar D., Zmora E. Nurses' reactions to alarms in a neonatal intensive care unit. Cogn Technol Work: 2004; 6 239 246
    • (2004) Cogn Technol Work , vol.6 , pp. 239-246
    • Bitan, Y.1    Meyer, J.2    Shinar, D.3    Zmora, E.4
  • 24
    • 41149091787 scopus 로고    scopus 로고
    • A national online survey on the effectiveness of clinical alarms
    • Korniewicz D. M., Clark T., David Y. A national online survey on the effectiveness of clinical alarms. Am J Crit Care: 2008; 17 36 41 Development
    • (2008) Am J Crit Care , vol.17 , pp. 36-41
    • Korniewicz, D.M.1    Clark, T.2    David, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.