메뉴 건너뛰기




Volumn 2014, Issue , 2014, Pages

Experimental investigation of thermohydraulic performance of a rectangular solar air heater duct equipped with V-shaped perforated blocks

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84893681197     PISSN: 16878132     EISSN: 16878140     Source Type: Journal    
DOI: 10.1155/2014/948313     Document Type: Article
Times cited : (26)

References (38)
  • 1
    • 45549112789 scopus 로고
    • Effect of artificial roughness on heat transfer and friction factor in a solar air heater
    • 2-s2.0-45549112789
    • Prasad B. N., Saini J. S., Effect of artificial roughness on heat transfer and friction factor in a solar air heater. Solar Energy 1988 41 6 555 560 2-s2.0-45549112789
    • (1988) Solar Energy , vol.41 , Issue.6 , pp. 555-560
    • Prasad, B.N.1    Saini, J.S.2
  • 2
    • 38248999748 scopus 로고
    • Heat and fluid flow in rectangular solar air heater ducts having transverse rib roughness on absorber plates
    • 2-s2.0-38248999748
    • Gupta D., Solanki S. C., Saini J. S., Heat and fluid flow in rectangular solar air heater ducts having transverse rib roughness on absorber plates. Solar Energy 1993 51 1 31 37 2-s2.0-38248999748
    • (1993) Solar Energy , vol.51 , Issue.1 , pp. 31-37
    • Gupta, D.1    Solanki, S.C.2    Saini, J.S.3
  • 3
    • 79959376607 scopus 로고    scopus 로고
    • Heat transfer and friction in solar air heater duct with W-shaped rib roughness on absorber plate
    • 2-s2.0-79959376607 10.1016/j.energy.2011.03.054
    • Lanjewar A., Bhagoria J. L., Sarviya R. M., Heat transfer and friction in solar air heater duct with W-shaped rib roughness on absorber plate. Energy 2011 36 7 4531 4541 2-s2.0-79959376607 10.1016/j.energy.2011.03.054
    • (2011) Energy , vol.36 , Issue.7 , pp. 4531-4541
    • Lanjewar, A.1    Bhagoria, J.L.2    Sarviya, R.M.3
  • 4
    • 55249107603 scopus 로고    scopus 로고
    • Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness
    • 2-s2.0-55249107603 10.1016/j.solener.2008.05.010
    • Saini S. K., Saini R. P., Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness. Solar Energy 2008 82 12 1118 1130 2-s2.0-55249107603 10.1016/j.solener.2008.05.010
    • (2008) Solar Energy , vol.82 , Issue.12 , pp. 1118-1130
    • Saini, S.K.1    Saini, R.P.2
  • 5
    • 79954614860 scopus 로고    scopus 로고
    • Nusselt number and friction factor correlations for solar air heater duct having artificially roughened absorber plate
    • 2-s2.0-79954614860 10.1016/j.solener.2011.03.007
    • Bhushan B., Singh R., Nusselt number and friction factor correlations for solar air heater duct having artificially roughened absorber plate. Solar Energy 2011 85 5 1109 1118 2-s2.0-79954614860 10.1016/j.solener.2011.03.007
    • (2011) Solar Energy , vol.85 , Issue.5 , pp. 1109-1118
    • Bhushan, B.1    Singh, R.2
  • 6
    • 38049025785 scopus 로고    scopus 로고
    • Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater
    • 2-s2.0-38049025785 10.1016/j.renene.2007.03.023
    • Aharwal K. R., Gandhi B. K., Saini J. S., Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater. Renewable Energy 2008 33 4 585 596 2-s2.0-38049025785 10.1016/j.renene.2007.03.023
    • (2008) Renewable Energy , vol.33 , Issue.4 , pp. 585-596
    • Aharwal, K.R.1    Gandhi, B.K.2    Saini, J.S.3
  • 7
    • 0037182562 scopus 로고    scopus 로고
    • Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate
    • DOI 10.1016/S0017-9310(02)00046-7, PII S0017931002000467
    • Ebrahim Momin A.-M., Saini J. S., Solanki S. C., Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate. International Journal of Heat and Mass Transfer 2002 45 16 3383 3396 2-s2.0-0037182562 10.1016/S0017-9310(02)00046-7 (Pubitemid 34714557)
    • (2002) International Journal of Heat and Mass Transfer , vol.45 , Issue.16 , pp. 3383-3396
    • Ebrahim Momin, A.-M.1    Saini, J.S.2    Solanki, S.C.3
  • 8
    • 77953135316 scopus 로고    scopus 로고
    • Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs
    • 2-s2.0-77953135316 10.1016/j.solener.2010.02.004
    • Hans V. S., Saini R. P., Saini J. S., Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs. Solar Energy 2010 84 6 898 911 2-s2.0-77953135316 10.1016/j.solener. 2010.02.004
    • (2010) Solar Energy , vol.84 , Issue.6 , pp. 898-911
    • Hans, V.S.1    Saini, R.P.2    Saini, J.S.3
  • 9
    • 84860575928 scopus 로고    scopus 로고
    • Experimental investigation on heat transfer and fluid flow characteristics of air flow in a rectangular duct with Multi v-shaped rib with gap roughness on the heated plate
    • 2-s2.0-84860575928 10.1016/j.solener.2012.03.014
    • Kumar A., Saini R. P., Saini J. S., Experimental investigation on heat transfer and fluid flow characteristics of air flow in a rectangular duct with Multi v-shaped rib with gap roughness on the heated plate. Solar Energy 2012 86 6 1733 1749 2-s2.0-84860575928 10.1016/j.solener.2012.03.014
    • (2012) Solar Energy , vol.86 , Issue.6 , pp. 1733-1749
    • Kumar, A.1    Saini, R.P.2    Saini, J.S.3
  • 10
    • 14644431830 scopus 로고    scopus 로고
    • Experimental study of heat transfer enhancement in an asymmetrically heated rectangular duct with perforated baffles
    • DOI 10.1016/j.icheatmasstransfer.2004.10.002, PII S0735193304001964
    • Karwa R., Maheshwari B. K., Karwa N., Experimental study of heat transfer enhancement in an asymmetrically heated rectangular duct with perforated baffles. International Communications in Heat and Mass Transfer 2005 32 1-2 275 284 2-s2.0-14644431830 10.1016/j.icheatmasstransfer.2004.10.002 (Pubitemid 40318177)
    • (2005) International Communications in Heat and Mass Transfer , vol.32 , Issue.1-2 , pp. 275-284
    • Karwa, R.1    Maheshwari, B.K.2    Karwa, N.3
  • 11
    • 84855347477 scopus 로고    scopus 로고
    • Heat transfer enhancement by multiple swirling impinging jets with twisted-tape swirl generators
    • 2-s2.0-84855347477 10.1016/j.icheatmasstransfer.2011.10.003
    • Nuntadusit C., Wae-hayee M., Bunyajitradulya A., Eiamsa-ard S., Heat transfer enhancement by multiple swirling impinging jets with twisted-tape swirl generators. International Communications in Heat and Mass Transfer 2012 39 1 102 107 2-s2.0-84855347477 10.1016/j.icheatmasstransfer.2011.10.003
    • (2012) International Communications in Heat and Mass Transfer , vol.39 , Issue.1 , pp. 102-107
    • Nuntadusit, C.1    Wae-Hayee, M.2    Bunyajitradulya, A.3    Eiamsa-Ard, S.4
  • 12
    • 0036603690 scopus 로고    scopus 로고
    • Shape optimization of rib-roughened surface to enhance turbulent heat transfer
    • DOI 10.1016/S0017-9310(01)00358-1, PII S0017931001003581
    • Kim K.-Y., Kim S.-S., Shape optimization of rib-roughened surface to enhance turbulent heat transfer. International Journal of Heat and Mass Transfer 2002 45 13 2719 2727 2-s2.0-0036603690 10.1016/S0017-9310(01)00358-1 (Pubitemid 34593189)
    • (2002) International Journal of Heat and Mass Transfer , vol.45 , Issue.13 , pp. 2719-2727
    • Kim, K.-Y.1    Kim, S.-S.2
  • 13
    • 60449103711 scopus 로고    scopus 로고
    • Heat transfer and friction in an asymmetrically heated rectangular duct with half and fully perforated baffles at different pitches
    • 2-s2.0-60449103711 10.1016/j.icheatmasstransfer.2008.11.005
    • Karwa R., Maheshwari B. K., Heat transfer and friction in an asymmetrically heated rectangular duct with half and fully perforated baffles at different pitches. International Communications in Heat and Mass Transfer 2009 36 3 264 268 2-s2.0-60449103711 10.1016/j.icheatmasstransfer.2008.11.005
    • (2009) International Communications in Heat and Mass Transfer , vol.36 , Issue.3 , pp. 264-268
    • Karwa, R.1    Maheshwari, B.K.2
  • 14
    • 0032104562 scopus 로고    scopus 로고
    • Turbulent heat and fluid flow in a passage disturbed by detached perforated ribs of different heights
    • PII S0017931097002421
    • Liou T.-M., Chen S.-H., Turbulent heat and fluid flow in a passage disturbed by detached perforated ribs of different heights. International Journal of Heat and Mass Transfer 1998 41 12 1795 1806 2-s2.0-0032104562 (Pubitemid 128397806)
    • (1998) International Journal of Heat and Mass Transfer , vol.41 , Issue.12 , pp. 1795-1806
    • Liou, T.-M.1    Chen, S.-H.2
  • 15
    • 0035479049 scopus 로고    scopus 로고
    • Heat-transfer enhancement in a channel flow with perforated rectangular blocks
    • DOI 10.1016/S0142-727X(01)00117-5, PII S0142727X01001175
    • Sara O. N., Pekdemir T., Yapici S., Yilmaz M., Heat-transfer enhancement in a channel flow with perforated rectangular blocks. International Journal of Heat and Fluid Flow 2001 22 5 509 518 2-s2.0-0035479049 10.1016/S0142-727X(01) 00117-5 (Pubitemid 32863508)
    • (2001) International Journal of Heat and Fluid Flow , vol.22 , Issue.5 , pp. 509-518
    • Sara, O.N.1    Pekdemir, T.2    Yapici, S.3    Yilmaz, M.4
  • 16
    • 0342810013 scopus 로고    scopus 로고
    • Thermal performance analysis for solid and perforated blocks attached on a flat surface in duct flow
    • DOI 10.1016/S0196-8904(99)00163-6
    • Şara O. N., Pekdemir T., Yapici S., Erşahan H., Thermal performance analysis for solid and perforated blocks attached on a flat surface in duct flow. Energy Conversion and Management 2000 41 10 1019 1028 2-s2.0-0342810013 10.1016/S0196-8904(99)00163-6 (Pubitemid 30567268)
    • (2000) Energy Conversion and Management , vol.41 , Issue.10 , pp. 1019-1028
    • Sara, O.N.1    Pekdemir, T.2    Yapici, S.3    Ersahan, H.4
  • 17
    • 0029411402 scopus 로고
    • Heat transfer in a rectangular channel with perforated turbulence promoters using holographic interferometry measurement
    • 2-s2.0-0029411402
    • Hwang J.-J., Liou T.-M., Heat transfer in a rectangular channel with perforated turbulence promoters using holographic interferometry measurement. International Journal of Heat and Mass Transfer 1995 38 17 3197 3207 2-s2.0-0029411402
    • (1995) International Journal of Heat and Mass Transfer , vol.38 , Issue.17 , pp. 3197-3207
    • Hwang, J.-J.1    Liou, T.-M.2
  • 18
    • 0035838025 scopus 로고    scopus 로고
    • Enhancement of heat transfer from a flat surface in a channel flow by attachment of rectangular blocks
    • 2-s2.0-0035838025 10.1002/er.703
    • Šara O. N., Pekdemir T., Yapc S., Ylmaz M., Enhancement of heat transfer from a flat surface in a channel flow by attachment of rectangular blocks. International Journal of Energy Research 2001 25 7 563 576 2-s2.0-0035838025 10.1002/er.703
    • (2001) International Journal of Energy Research , vol.25 , Issue.7 , pp. 563-576
    • Šara, O.N.1    Pekdemir, T.2    Yapc, S.3    Ylmaz, M.4
  • 19
    • 62349094054 scopus 로고    scopus 로고
    • Effect of hole shape on the heat transfer in a rectangular duct with perforated blockage walls
    • 2-s2.0-62349094054 10.1007/s12206-008-0736-7
    • Shin S., Kwak J. S., Effect of hole shape on the heat transfer in a rectangular duct with perforated blockage walls. Journal of Mechanical Science and Technology 2008 22 10 1945 1951 2-s2.0-62349094054 10.1007/s12206-008-0736-7
    • (2008) Journal of Mechanical Science and Technology , vol.22 , Issue.10 , pp. 1945-1951
    • Shin, S.1    Kwak, J.S.2
  • 20
    • 0036206792 scopus 로고    scopus 로고
    • Convective heat transfer in a channel with perforated ribs
    • 2-s2.0-0036206792 10.1016/S1290-0729(02)01323-6
    • Buchlin J.-M., Convective heat transfer in a channel with perforated ribs. International Journal of Thermal Sciences 2002 41 4 332 340 2-s2.0-0036206792 10.1016/S1290-0729(02)01323-6
    • (2002) International Journal of Thermal Sciences , vol.41 , Issue.4 , pp. 332-340
    • Buchlin, J.-M.1
  • 21
    • 84877277520 scopus 로고    scopus 로고
    • Heat transfer enhancement in solar air heater with V-shaped perforated baffles
    • 10.1063/1.4798411 023122
    • Chamoli S., Thakur N. S., Heat transfer enhancement in solar air heater with V-shaped perforated baffles. Journal of Renewable and Sustainable Energy 2013 5 10.1063/1.4798411 023122
    • (2013) Journal of Renewable and Sustainable Energy , vol.5
    • Chamoli, S.1    Thakur, N.S.2
  • 22
    • 0026816813 scopus 로고
    • High performance heat transfer ducts with parallel broken and V-shaped broken ribs
    • 2-s2.0-0026816813
    • Han J. C., Zhang Y. M., High performance heat transfer ducts with parallel broken and V-shaped broken ribs. International Journal of Heat and Mass Transfer 1992 35 2 513 523 2-s2.0-0026816813
    • (1992) International Journal of Heat and Mass Transfer , vol.35 , Issue.2 , pp. 513-523
    • Han, J.C.1    Zhang, Y.M.2
  • 23
    • 0027596118 scopus 로고
    • Local heat/mass transfer distribution in a square channel with full and V-shaped ribs
    • Kukreja R. T., Lau S. C., McMillin R. D., Local heat/mass transfer distribution in a square channel with full and V-shaped ribs. International Journal of Heat and Mass Transfer 1993 36 8 2013 2020 2-s2.0-0027596118 (Pubitemid 23672028)
    • (1993) International Journal of Heat and Mass Transfer , vol.36 , Issue.8 , pp. 2013-2020
    • Kukreja, R.T.1    Lau, S.C.2    McMillin, R.D.3
  • 24
    • 0031988410 scopus 로고    scopus 로고
    • Effect of fence thickness on pressure drop and heat transfer in a perforated-fenced channel
    • PII S0017931097001695
    • Hwang J. J., Lia T. Y., Liou T.-M., Effect of fence thickness on pressure drop and heat transfer in a perforated-fenced channel. International Journal of Heat and Mass Transfer 1998 41 4-5 811 816 2-s2.0-0031988410 (Pubitemid 128397147)
    • (1998) International Journal of Heat and Mass Transfer , vol.41 , Issue.4-5 , pp. 811-816
    • Hwang, J.J.1    Lia, T.Y.2    Liou, T.-M.3
  • 25
    • 0042919552 scopus 로고    scopus 로고
    • Heat transfer between blockages with holes in a rectangular channel
    • DOI 10.1115/1.1576812
    • Moon S. W., Lau S. C., Heat transfer between blockages with holes in a rectangular channel. Journal of Heat Transfer 2003 125 4 587 594 2-s2.0-0042919552 10.1115/1.1576812 (Pubitemid 37078526)
    • (2003) Journal of Heat Transfer , vol.125 , Issue.4 , pp. 587-594
    • Moon, S.W.1    Lau, S.C.2
  • 26
    • 78449308766 scopus 로고    scopus 로고
    • Numerical investigation on synthetical performances of fluid flow and heat transfer of semiattached rib-channels
    • 2-s2.0-78449308766 10.1016/j.ijheatmasstransfer.2010.09.013
    • Liu H., Wang J., Numerical investigation on synthetical performances of fluid flow and heat transfer of semiattached rib-channels. International Journal of Heat and Mass Transfer 2011 54 1-3 575 583 2-s2.0-78449308766 10.1016/j.ijheatmasstransfer.2010.09.013
    • (2011) International Journal of Heat and Mass Transfer , vol.54 , Issue.1-3 , pp. 575-583
    • Liu, H.1    Wang, J.2
  • 27
    • 31144440572 scopus 로고    scopus 로고
    • Flow and heat transfer in the wake of a surface-mounted rib with a slit
    • Tariq A., Panigrahi P. K., Muralidhar K., Flow and heat transfer in the wake of a surface-mounted rib with a slit. Experiments in Fluids 2004 37 701 719
    • (2004) Experiments in Fluids , vol.37 , pp. 701-719
    • Tariq, A.1    Panigrahi, P.K.2    Muralidhar, K.3
  • 28
    • 0028050754 scopus 로고
    • Heat transfer and friction in rectangular channels with ribbed or ribbed-grooved walls
    • Zhang Y. M., Gu W. Z., Han J. C., Heat transfer and friction in rectangular channels with ribbed or ribbed-grooved walls. Journal of Heat Transfer 1994 116 1 58 65 2-s2.0-0028050754 (Pubitemid 277394)
    • (1994) Transactions - ASME: Journal of Heat Transfer , vol.116 , Issue.1 , pp. 58-65
    • Zhang, Y.M.1    Gu, W.Z.2    Han, J.C.3
  • 29
    • 0028486550 scopus 로고
    • Performance evaluation criteria for enhanced heat transfer surfaces
    • Zimparov V. D., Vulchanov N. L., Performance evaluation criteria for enhanced heat transfer surfaces. International Journal of Heat and Mass Transfer 1994 37 12 1807 1816 2-s2.0-0028486550 (Pubitemid 281266)
    • (1994) International Journal of Heat & Mass Transfer , vol.37 , Issue.12 , pp. 1807-1816
    • Zimparov, V.D.1    Vulchanov, N.L.2
  • 30
    • 0035251268 scopus 로고    scopus 로고
    • Thermo-hydraulic performance of solar air heaters having integral chamfered rib roughness on absorber plates
    • DOI 10.1016/S0360-5442(00)00062-1, PII S0360544200000621
    • Karwa R., Solanki S. C., Saini J. S., Thermo-hydraulic performance of solar air heaters having integral chamfered rib roughness on absorber plates. Energy 2001 26 2 161 176 2-s2.0-0035251268 10.1016/S0360-5442(00)00062-1 (Pubitemid 32207948)
    • (2001) Energy , vol.26 , Issue.2 , pp. 161-176
    • Karwa, R.1    Solanki, S.C.2    Saini, J.S.3
  • 31
    • 0001641533 scopus 로고
    • Optimising the thermohydraulic performance of rough surfaces
    • 2-s2.0-0001641533
    • Lewis M. J., Optimising the thermohydraulic performance of rough surfaces. International Journal of Heat and Mass Transfer 1975 18 11 1243 1248 2-s2.0-0001641533
    • (1975) International Journal of Heat and Mass Transfer , vol.18 , Issue.11 , pp. 1243-1248
    • Lewis, M.J.1
  • 32
    • 84893696373 scopus 로고    scopus 로고
    • Performance evaluation criterion at equal pumping power for enhanced performance heat transfer surfaces
    • 370823 10.1155/2013/370823
    • Karwa R., Sharma C., Karwa N., Performance evaluation criterion at equal pumping power for enhanced performance heat transfer surfaces. Journal of Solar Energy 2013 2013 9 370823 10.1155/2013/370823
    • (2013) Journal of Solar Energy , vol.2013 , pp. 9
    • Karwa, R.1    Sharma, C.2    Karwa, N.3
  • 33
    • 84862322427 scopus 로고    scopus 로고
    • Investigations on thermo-hydraulic performance due to flow-attack-angle in V-down rib with gap in a rectangular duct of solar air heater
    • 2-s2.0-84855163831 10.1016/j.apenergy.2011.11.090
    • Singh S., Chander S., Saini J. S., Investigations on thermo-hydraulic performance due to flow-attack-angle in V-down rib with gap in a rectangular duct of solar air heater. Applied Energy 2012 97 907 912 2-s2.0-84855163831 10.1016/j.apenergy.2011.11.090
    • (2012) Applied Energy , vol.97 , pp. 907-912
    • Singh, S.1    Chander, S.2    Saini, J.S.3
  • 35
    • 34247578708 scopus 로고    scopus 로고
    • Experimental investigation of local heat transfer in a square duct with various-shaped ribs
    • DOI 10.1007/s00231-006-0190-y
    • Wang L., Sundén B., Experimental investigation of local heat transfer in a square duct with various-shaped ribs. Heat and Mass Transfer 2007 43 8 759 766 2-s2.0-34247578708 10.1007/s00231-006-0190-y (Pubitemid 46675526)
    • (2007) Heat and Mass Transfer/Waerme- und Stoffuebertragung , vol.43 , Issue.8 , pp. 759-766
    • Wang, L.1    Sunden, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.