메뉴 건너뛰기




Volumn 45, Issue 2, 2014, Pages 456-461

Assessing reperfusion with whole-brain arterial spin labeling a noninvasive alternative to gadolinium

Author keywords

Magnetic resonance imaging; Perfusion imaging

Indexed keywords

GADOLINIUM PENTETATE MEGLUMINE; TISSUE PLASMINOGEN ACTIVATOR;

EID: 84893676876     PISSN: 00392499     EISSN: 15244628     Source Type: Journal    
DOI: 10.1161/STROKEAHA.113.004001     Document Type: Article
Times cited : (29)

References (22)
  • 1
  • 2
    • 70449727619 scopus 로고    scopus 로고
    • Evidence-based approach for prevention of radiocontrast-induced nephropathy
    • Abu Jawdeh BG, Kanso AA, Schelling JR. Evidence-based approach for prevention of radiocontrast-induced nephropathy. J Hosp Med. 2009;4:500-506.
    • (2009) J Hosp Med , vol.4 , pp. 500-506
    • Abu Jawdeh, B.G.1    Kanso, A.A.2    Schelling, J.R.3
  • 3
    • 34250830251 scopus 로고    scopus 로고
    • Gadolinium-induced nephrogenic systemic fibrosis in patients with kidney disease
    • Perazella MA, Rodby RA. Gadolinium-induced nephrogenic systemic fibrosis in patients with kidney disease. Am J Med. 2007;120:561-562.
    • (2007) Am J Med , vol.120 , pp. 561-562
    • Perazella, M.A.1    Rodby, R.A.2
  • 5
    • 77952428397 scopus 로고    scopus 로고
    • An arterial spin labeling investigation of cerebral blood flow deficits in chronic stroke survivors
    • Brumm KP, Perthen JE, Liu TT, Haist F, Ayalon L, Love T. An arterial spin labeling investigation of cerebral blood flow deficits in chronic stroke survivors. Neuroimage. 2010;51:995-1005.
    • (2010) Neuroimage , vol.51 , pp. 995-1005
    • Brumm, K.P.1    Perthen, J.E.2    Liu, T.T.3    Haist, F.4    Ayalon, L.5    Love, T.6
  • 6
    • 0030615065 scopus 로고    scopus 로고
    • Comparison of EPISTAR and T2*-weighted gadolinium-enhanced perfusion imaging in patients with acute cerebral ischemia
    • Siewert B, Schlaug G, Edelman RR, Warach S. Comparison of EPISTAR and T2*-weighted gadolinium-enhanced perfusion imaging in patients with acute cerebral ischemia. Neurology. 1997;48:673-679.
    • (1997) Neurology , vol.48 , pp. 673-679
    • Siewert, B.1    Schlaug, G.2    Edelman, R.R.3    Warach, S.4
  • 7
    • 34247844511 scopus 로고    scopus 로고
    • Guidelines for the early management of adults with ischemic stroke: A guideline from the American Heart Association
    • American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council, and the Atherosclerotic Peripheral Vascular Disease and Quality of Care Outcomes in Research Interdisciplinary Working Groups: The American Academy of Neurology affirms the value of this guideline as an educational tool for neurologists
    • Adams HP Jr, del Zoppo G, Alberts MJ, Bhatt DL, Brass L, Furlan A, et al. Guidelines for the early management of adults with ischemic stroke: a guideline from the American Heart Association/ American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council, and the Atherosclerotic Peripheral Vascular Disease and Quality of Care Outcomes in Research Interdisciplinary Working Groups: the American Academy of Neurology affirms the value of this guideline as an educational tool for neurologists. Stroke. 2007;38:1655-1711.
    • (2007) Stroke , vol.38 , pp. 1655-1711
    • Adams Jr., H.P.1    Del Zoppo, G.2    Alberts, M.J.3    Bhatt, D.L.4    Brass, L.5    Furlan, A.6
  • 8
    • 68749100878 scopus 로고    scopus 로고
    • Expansion of the time window for treatment of acute ischemic stroke with intravenous tissue plasminogen activator: A science advisory from the American Heart Association/American Stroke Association
    • American Heart Association Stroke Council
    • Del Zoppo GJ, Saver JL, Jauch EC, Adams HP Jr; American Heart Association Stroke Council. Expansion of the time window for treatment of acute ischemic stroke with intravenous tissue plasminogen activator: a science advisory from the American Heart Association/American Stroke Association. Stroke. 2009;40:2945-2948.
    • (2009) Stroke , vol.40 , pp. 2945-2948
    • Del Zoppo, G.J.1    Saver, J.L.2    Jauch, E.C.3    Adams Jr., H.P.4
  • 9
    • 57149104587 scopus 로고    scopus 로고
    • Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields
    • Dai W, Garcia D, de Bazelaire C, Alsop DC. Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med. 2008;60:1488-1497.
    • (2008) Magn Reson Med , vol.60 , pp. 1488-1497
    • Dai, W.1    Garcia, D.2    De Bazelaire, C.3    Alsop, D.C.4
  • 11
    • 0033936617 scopus 로고    scopus 로고
    • Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST)
    • Ye FQ, Frank JA, Weinberger DR, McLaughlin AC. Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST). Magn Reson Med. 2000;44:92-100.
    • (2000) Magn Reson Med , vol.44 , pp. 92-100
    • Ye, F.Q.1    Frank, J.A.2    Weinberger, D.R.3    McLaughlin, A.C.4
  • 12
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop DC, Detre JA. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab. 1996;16:1236-1249.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 13
    • 12144281348 scopus 로고    scopus 로고
    • Pulsed star labeling of arterial regions (PULSAR): A robust regional perfusion technique for high field imaging
    • Golay X, Petersen ET, Hui F. Pulsed star labeling of arterial regions (PULSAR): a robust regional perfusion technique for high field imaging. Magn Reson Med. 2005;53:15-21.
    • (2005) Magn Reson Med , vol.53 , pp. 15-21
    • Golay, X.1    Petersen, E.T.2    Hui, F.3
  • 14
    • 12844281921 scopus 로고    scopus 로고
    • Effects of the apparent transverse relaxation time on cerebral blood flow measurements obtained by arterial spin labeling
    • St Lawrence KS, Wang J. Effects of the apparent transverse relaxation time on cerebral blood flow measurements obtained by arterial spin labeling. Magn Reson Med. 2005;53:425-433.
    • (2005) Magn Reson Med , vol.53 , pp. 425-433
    • St Lawrence, K.S.1    Wang, J.2
  • 15
    • 33845415008 scopus 로고    scopus 로고
    • Intraand interrater reliability of ischemic lesion volume measurements on diffusion- weighted, mean transit time and fluid-attenuated inversion recovery MRI
    • Luby M, Bykowski JL, Schellinger PD, Merino JG, Warach S. Intraand interrater reliability of ischemic lesion volume measurements on diffusion- weighted, mean transit time and fluid-attenuated inversion recovery MRI. Stroke. 2006;37:2951-2956.
    • (2006) Stroke , vol.37 , pp. 2951-2956
    • Luby, M.1    Bykowski, J.L.2    Schellinger, P.D.3    Merino, J.G.4    Warach, S.5
  • 16
    • 84876296898 scopus 로고    scopus 로고
    • Periprocedural arterial spin labeling and dynamic susceptibility contrast perfusion in detection of cerebral blood flow in patients with acute ischemic syndrome
    • UCLA Stroke Investigators
    • Nael K, Meshksar A, Liebeskind DS, Wang DJ, Ellingson BM, Salamon N, et al; UCLA Stroke Investigators. Periprocedural arterial spin labeling and dynamic susceptibility contrast perfusion in detection of cerebral blood flow in patients with acute ischemic syndrome. Stroke. 2013;44:664-670.
    • (2013) Stroke , vol.44 , pp. 664-670
    • Nael, K.1    Meshksar, A.2    Liebeskind, D.S.3    Wang, D.J.4    Ellingson, B.M.5    Salamon, N.6
  • 17
    • 84888291296 scopus 로고    scopus 로고
    • Quantitative analysis of hypoperfusion in acute stroke: Arterial spin labeling versus dynamic susceptibility contrast
    • Nael K, Meshksar A, Liebeskind DS, Coull BM, Krupinski EA, Villablanca JP. Quantitative analysis of hypoperfusion in acute stroke: arterial spin labeling versus dynamic susceptibility contrast. Stroke. 2013;44:3090-3096.
    • (2013) Stroke , vol.44 , pp. 3090-3096
    • Nael, K.1    Meshksar, A.2    Liebeskind, D.S.3    Coull, B.M.4    Krupinski, E.A.5    Villablanca, J.P.6
  • 18
    • 84857654535 scopus 로고    scopus 로고
    • Pseudocontinuous arterial spin labeling quantifies relative cerebral blood flow in acute stroke
    • Hernandez DA, Bokkers RP, Mirasol RV, Luby M, Henning EC, Merino JG, et al. Pseudocontinuous arterial spin labeling quantifies relative cerebral blood flow in acute stroke. Stroke. 2012;43:753-758.
    • (2012) Stroke , vol.43 , pp. 753-758
    • Hernandez, D.A.1    Bokkers, R.P.2    Mirasol, R.V.3    Luby, M.4    Henning, E.C.5    Merino, J.G.6
  • 19
    • 84860225375 scopus 로고    scopus 로고
    • Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke
    • National Institutes of Health Stroke Natural History Investigators
    • Bokkers RP, Hernandez DA, Merino JG, Mirasol RV, van Osch MJ, Hendrikse J, et al; National Institutes of Health Stroke Natural History Investigators. Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke. Stroke. 2012;43:1290-1294.
    • (2012) Stroke , vol.43 , pp. 1290-1294
    • Bokkers, R.P.1    Hernandez, D.A.2    Merino, J.G.3    Mirasol, R.V.4    Van Osch, M.J.5    Hendrikse, J.6
  • 20
    • 84879751963 scopus 로고    scopus 로고
    • Continuous magnetic resonance perfusion imaging acquisition during systemic thrombolysis in acute stroke
    • Griebe M, Kern R, Eisele P, Sick C, Wolf ME, Sauter-Servaes J, et al. Continuous magnetic resonance perfusion imaging acquisition during systemic thrombolysis in acute stroke. Cerebrovasc Dis. 2013;35:554-559.
    • (2013) Cerebrovasc Dis , vol.35 , pp. 554-559
    • Griebe, M.1    Kern, R.2    Eisele, P.3    Sick, C.4    Wolf, M.E.5    Sauter-Servaes, J.6
  • 21
    • 84868641708 scopus 로고    scopus 로고
    • Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations
    • Wang Z. Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations. Magn Reson Imaging. 2012;30:1409-1415.
    • (2012) Magn Reson Imaging , vol.30 , pp. 1409-1415
    • Wang, Z.1
  • 22
    • 84865313143 scopus 로고    scopus 로고
    • Automated vs manual delineations of regions of interest - A comparison in commercially available perfusion MRI software
    • Galinovic I, Ostwaldt AC, Soemmer C, Bros H, Hotter B, Brunecker P, et al. Automated vs manual delineations of regions of interest- a comparison in commercially available perfusion MRI software. BMC Med Imaging. 2012;12:16.
    • (2012) BMC Med Imaging , vol.12 , pp. 16
    • Galinovic, I.1    Ostwaldt, A.C.2    Soemmer, C.3    Bros, H.4    Hotter, B.5    Brunecker, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.