메뉴 건너뛰기




Volumn 45, Issue , 2014, Pages 1354-1363

Experimental analysis of optimal operation mode of a ground source heat pump system

Author keywords

Coefficient of performance; Experimental; GSHP; Model; Variable speed

Indexed keywords


EID: 84893667989     PISSN: 18766102     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1016/j.egypro.2014.01.142     Document Type: Conference Paper
Times cited : (9)

References (9)
  • 1
    • 0037209522 scopus 로고    scopus 로고
    • Theoretical and basic experimental analysis on load adjustment of geothermal heat pump systems
    • Zhao L, Zhao LL, Zhang Q, Ding GL Theoretical and basic experimental analysis on load adjustment of geothermal heat pump systems. Energy Conversion and Management, 2003, 44. p. 1-9
    • (2003) Energy Conversion and Management , vol.44 , pp. 1-9
    • Zhao, L.1    Zhao, L.L.2    Zhang, Q.3    Ding, G.L.4
  • 3
  • 4
    • 33846050553 scopus 로고    scopus 로고
    • Capacity-controlled ground source heat pumps in hydronic heating systems
    • Karlsson F, Fahlén P. Capacity-controlled ground source heat pumps in hydronic heating systems. International Journal of Refrigeration, 2007, 30. p. 221-229
    • (2007) International Journal of Refrigeration , vol.30 , pp. 221-229
    • Karlsson, F.1    Fahlén, P.2
  • 5
    • 79961020524 scopus 로고    scopus 로고
    • Capacity control in ground source heat pump systems part I: Modeling and simulation
    • Madani H, Claesson J, Lundqvist P. Capacity control in ground source heat pump systems part I: modeling and simulation. International Journal of Refrigeration, 2011, 34. p. 1338-1347
    • (2011) International Journal of Refrigeration , vol.34 , pp. 1338-1347
    • Madani, H.1    Claesson, J.2    Lundqvist, P.3
  • 6
    • 80955133856 scopus 로고    scopus 로고
    • Capacity control in ground source heat pump systems part II: Comparative analysis between on/off controlled and variable capacity systems
    • Madani H, Claesson J, Lundqvist P. Capacity control in ground source heat pump systems part II: comparative analysis between on/off controlled and variable capacity systems. International Journal of Refrigeration, 2011, 3. p. 1934-1942
    • (2011) International Journal of Refrigeration , vol.3 , pp. 1934-1942
    • Madani, H.1    Claesson, J.2    Lundqvist, P.3
  • 7
    • 77955177157 scopus 로고    scopus 로고
    • Dynamic performance of ground-source heat pumps fitted with frequency inverters for part-load control
    • Lee CK. Dynamic performance of ground-source heat pumps fitted with frequency inverters for part-load control. Applied Energy, 2010, 87. p. 3507-3513
    • (2010) Applied Energy , vol.87 , pp. 3507-3513
    • Lee, C.K.1
  • 8
    • 77957710733 scopus 로고    scopus 로고
    • Reversible heat pump model for seasonal performance optimization
    • Kinab E, Marchio D, Rivière P, Zoughaib A. Reversible heat pump model for seasonal performance optimization. Energy and Buildings, 2010, 42. p. 2269-2280
    • (2010) Energy and Buildings , vol.42 , pp. 2269-2280
    • Kinab, E.1    Marchio, D.2    Rivière, P.3    Zoughaib, A.4
  • 9
    • 78049462467 scopus 로고    scopus 로고
    • A quasi-steady state mathematical model of an integrated ground source heat pump for building space control
    • Corberan JM, Finn DP, Montagud C.M., Murphy FT, Edwards KC A quasi-steady state mathematical model of an integrated ground source heat pump for building space control. Energy and Buildings, 2011, 43. p. 82-92
    • (2011) Energy and Buildings , vol.43 , pp. 82-92
    • Corberan, J.M.1    Finn, D.P.2    Montagud, C.M.3    Murphy, F.T.4    Edwards, K.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.