1
-
-
17844392466
-
-
National Institute for Occupational Safety and Health (NIOSH) Available: Accessed 2013, Feb 8
-
National Institute for Occupational Safety and Health (NIOSH) (2003). Respirator usage in private sector firms, 2001. Available: http://www.cdc.gov/ niosh/docs/respsurv/. Accessed 2013, Feb 8
-
(2003)
Respirator Usage in Private Sector Firms, 2001
-
-
-
2
-
-
84893633646
-
-
National Personal Protective Technology Laboratory (NPPTL) Available: Accessed 2013, Feb 8
-
National Personal Protective Technology Laboratory (NPPTL) (2012). Standard respirator testing procedures. Available: http://www.cdc.gov/niosh/ npptl/stps/APresp.html. Accessed 2013, Feb 8
-
(2012)
Standard Respirator Testing Procedures
-
-
-
3
-
-
17544366372
-
Acceptable breathing resistance for respirator use
-
Love RG (1983) Acceptable breathing resistance for respirator use. J Int Soc Resp Protect 1: 45-66.
-
(1983)
J Int Soc Resp Protect
, vol.1
, pp. 45-66
-
-
Love, R.G.1
-
4
-
-
67650238022
-
Effect on breathing resistance of a surgical mask worn over a N95 filtering facepiece respirator
-
Vojtko MR, Roberge MR, Vojtko RJ, Roberge RJ (2008) Effect on breathing resistance of a surgical mask worn over a N95 filtering facepiece respirator. J Int Soc Resp Protect 25: 1-8.
-
(2008)
J Int Soc Resp Protect
, vol.25
, pp. 1-8
-
-
Vojtko, M.R.1
Roberge, M.R.2
Vojtko, R.J.3
Roberge, R.J.4
-
5
-
-
77955900463
-
Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators
-
doi:10.1093/annhyg/meq042. PubMed: 20522519
-
Roberge RJ, Bayer E, Powell JB, Coca A, Roberge MR et al. (2010) Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators. Ann Occup Hyg 54: 671-677. doi:10.1093/annhyg/meq042. PubMed: 20522519.
-
(2010)
Ann Occup Hyg
, vol.54
, pp. 671-677
-
-
Roberge, R.J.1
Bayer, E.2
Powell, J.B.3
Coca, A.4
Roberge, M.R.5
-
6
-
-
84875197700
-
Evaluation of N95 respirator use with a surgical mask cover: Effects on breathing resistance and inhaled carbon dioxide
-
doi:10.1093/annhyg/mes068. PubMed: 23108786
-
Sinkule EJ, Powell JB, Goss FL (2013) Evaluation of N95 respirator use with a surgical mask cover: effects on breathing resistance and inhaled carbon dioxide. Ann Occup Hyg 57: 384-398. doi:10.1093/annhyg/mes068. PubMed: 23108786.
-
(2013)
Ann Occup Hyg
, vol.57
, pp. 384-398
-
-
Sinkule, E.J.1
Powell, J.B.2
Goss, F.L.3
-
7
-
-
0025790063
-
The physiological cost of wearing a disposable respirator
-
doi:10.1080/15298669191364631. PubMed: 1858664
-
Jones JG (1991) The physiological cost of wearing a disposable respirator. Am Ind Hyg Assoc J 52: 219-225. doi:10.1080/15298669191364631. PubMed: 1858664.
-
(1991)
Am Ind Hyg Assoc J
, vol.52
, pp. 219-225
-
-
Jones, J.G.1
-
8
-
-
80054760152
-
Objective assessment of increase in breathing resistance of N95 respirators on human subjects
-
doi:10.1093/annhyg/mer065. PubMed: 21893677
-
Lee HP, Wang DY (2011) Objective assessment of increase in breathing resistance of N95 respirators on human subjects. Ann Occup Hyg 55: 917-921. doi:10.1093/annhyg/mer065. PubMed: 21893677.
-
(2011)
Ann Occup Hyg
, vol.55
, pp. 917-921
-
-
Lee, H.P.1
Wang, D.Y.2
-
9
-
-
0026518807
-
Evaluation of active anterior and posterior rhinomanometry in normal subjects
-
doi:10.1111/j.1365-2273.1992.tb01068.x. PubMed: 1587036
-
Shelton DM, Eiser NM (1992) Evaluation of active anterior and posterior rhinomanometry in normal subjects. Clin Otolaryngol Allied Sci 17: 178-182. doi:10.1111/j.1365-2273.1992.tb01068.x. PubMed: 1587036.
-
(1992)
Clin Otolaryngol Allied Sci
, vol.17
, pp. 178-182
-
-
Shelton, D.M.1
Eiser, N.M.2
-
10
-
-
40649118173
-
What do healthcare workers think? A survey of facial protection equipment user preferences
-
Bryce E, Forrester L, Scharf S, Eshghpour M (2007) What do healthcare workers think? A survey of facial protection equipment user preferences. J Hosp Infect 68: 241-247.
-
(2007)
J Hosp Infect
, vol.68
, pp. 241-247
-
-
Bryce, E.1
Forrester, L.2
Scharf, S.3
Eshghpour, M.4
-
11
-
-
74449084898
-
Health care workers' views about respirator use and features that should be included in the next generation of respirators
-
doi:10.1016/S0196-6553(10)00196-3. PubMed: 20036443
-
Baig AS, Knapp C, Eagan AE, Radonovich LJ Jr (2010) Health care workers' views about respirator use and features that should be included in the next generation of respirators. Am J Infect Control 38: 18-25. doi:10.1016/S0196- 6553(10)00196-3. PubMed: 20036443.
-
(2010)
Am J Infect Control
, vol.38
, pp. 18-25
-
-
Baig, A.S.1
Knapp, C.2
Eagan, A.E.3
Radonovich Jr., L.J.4
-
12
-
-
84865756275
-
Impact of the 2009 influenza A (H1N1) pandemic on Canadian health care workers: A survey on vaccination, illness, absenteeism, and person protective equipment
-
doi:10.1016/j.ajic.2012.01.011. PubMed: 22575285
-
Mitchell R, Ogunremi T, Astrakianakis G, Bryce E, Gervais R et al. (2012) Impact of the 2009 influenza A (H1N1) pandemic on Canadian health care workers: A survey on vaccination, illness, absenteeism, and person protective equipment. Am J Infect Control 40: 611-616. doi:10.1016/j.ajic.2012.01.011. PubMed: 22575285.
-
(2012)
Am J Infect Control
, vol.40
, pp. 611-616
-
-
Mitchell, R.1
Ogunremi, T.2
Astrakianakis, G.3
Bryce, E.4
Gervais, R.5
-
14
-
-
0004208445
-
-
Standard 1910: 134. Available: Accessed 11 February 2013
-
Occupational Safety and Health Administration (OSHA) (1998) Respiratory Protection. Standard 1910: 134. Available: http://www.osha.gov/pls/oshaweb/ owadisp.show-document?p-id=12716&p-table=standards. Accessed 11 February 2013
-
(1998)
Respiratory Protection
-
-
-
15
-
-
84857245211
-
Reliability and validity of the Zephyr Bioharness to measure respiratory responses to exercise
-
Hailstone J, Kilding AE (2011) Reliability and validity of the Zephyr Bioharness to measure respiratory responses to exercise. Meas Phys Educ Exer Sci 32: 819-821.
-
(2011)
Meas Phys Educ Exer Sci
, vol.32
, pp. 819-821
-
-
Hailstone, J.1
Kilding, A.E.2
-
16
-
-
84878785306
-
Measurement accuracy of heart rate and respiratory rate during graded exercise and sustained exercise in the heat using the Zephyr Bioharness™
-
doi:10.1055/s-0032-1327661. PubMed: 23175181
-
Kim H-J, Roberge RJ, Powell JB, Shafer AR, Williams WJ (2013) Measurement accuracy of heart rate and respiratory rate during graded exercise and sustained exercise in the heat using the Zephyr Bioharness™. Int J Sports Med 34: 497-501. doi:10.1055/s-0032-1327661. PubMed: 23175181.
-
(2013)
Int J Sports Med
, vol.34
, pp. 497-501
-
-
Kim, H.-J.1
Roberge, R.J.2
Powell, J.B.3
Shafer, A.R.4
Williams, W.J.5
-
17
-
-
77950253215
-
Physiological impact of the N95 filtering facepiece respirator on healthcare workers
-
PubMed: 20420727
-
Roberge RJ, Coca A, Williams WJ, Powell JB, Palmiero AJ (2010) Physiological impact of the N95 filtering facepiece respirator on healthcare workers. Respir Care 55: 569-577. PubMed: 20420727.
-
(2010)
Respir Care
, vol.55
, pp. 569-577
-
-
Roberge, R.J.1
Coca, A.2
Williams, W.J.3
Powell, J.B.4
Palmiero, A.J.5
-
18
-
-
77950252924
-
Surgical mask placement over N95 filtering facepiece respirators: Physiological effects on healthcare workers
-
doi:10.1111/j.1440-1843.2010.01713.x. PubMed: 20337987
-
Roberge RJ, Coca A, Williams WJ, Palmiero AJ, Powell JB (2010) Surgical mask placement over N95 filtering facepiece respirators: Physiological effects on healthcare workers. Respirology 15: 516-521. doi:10.1111/j.1440-1843.2010. 01713.x. PubMed: 20337987.
-
(2010)
Respirology
, vol.15
, pp. 516-521
-
-
Roberge, R.J.1
Coca, A.2
Williams, W.J.3
Palmiero, A.J.4
Powell, J.B.5
-
19
-
-
79957645620
-
Heat and humidity buildup under earmuff-type hearing protectors
-
doi:10.4103/1463-1741.77200. PubMed: 21368434
-
Davis RR, Shaw PB (2011) Heat and humidity buildup under earmuff-type hearing protectors. Noise Health 13: 93-98. doi:10.4103/1463-1741.77200. PubMed: 21368434.
-
(2011)
Noise Health
, vol.13
, pp. 93-98
-
-
Davis, R.R.1
Shaw, P.B.2
-
20
-
-
84857694961
-
N95 filtering facepiece respirator deadspace temperature and humidity
-
Roberge RJ, Kim J-H, Benson S (2012) N95 filtering facepiece respirator deadspace temperature and humidity. J Occup Environ Health 9: 166-171
-
(2012)
J Occup Environ Health
, vol.9
, pp. 166-171
-
-
Roberge, R.J.1
Kim, J.-H.2
Benson, S.3
-
21
-
-
0025270067
-
Psychophysical scaling with applications in physical work and the perception of exertion
-
doi:10.5271/sjweh.1815. PubMed: 2345867
-
Borg G (1990) Psychophysical scaling with applications in physical work and the perception of exertion. Scand J Work Environ Health 16 (Suppl 1): 55-58. doi:10.5271/sjweh.1815. PubMed: 2345867.
-
(1990)
Scand J Work Environ Health
, vol.16
, Issue.SUPPL. 1
, pp. 55-58
-
-
Borg, G.1
-
22
-
-
0032944883
-
Relative contribution of core and cutaneous temperatures to thermal comfort and autonomic responses in humans
-
Frank SM, Raja SN, Bulcao CF, Goldstein DS (1999) Relative contribution of core and cutaneous temperatures to thermal comfort, and the autonomic response in humans. Journal of Appl Physiol 86: 1588-1593. PubMed: 10233122. (Pubitemid 29230303)
-
(1999)
Journal of Applied Physiology
, vol.86
, Issue.5
, pp. 1588-1593
-
-
Frank, S.M.1
Raja, S.N.2
Bulcao, C.F.3
Goldstein, D.S.4
-
23
-
-
84893609152
-
-
Air Force Materiel Command, Brooks Air Force Base, Texas, Report AL-TP-1992-0061 Available: Accessed 11 February 2013
-
Antunano MJ, Baumgardner FW, Chen YT, Constable SH (1993) Characterization of chemical defense mask breathing resistance tolerances. Air Force Materiel Command, Brooks Air Force Base, Texas, Report AL-TP-1992-0061 Available: http://www.dtic.mil/cgi-bin/GetTRDoc?Location=U2&doc=GetTRDoc. pdf&AD=ADA265221. Accessed 11 February 2013
-
(1993)
Characterization of Chemical Defense Mask Breathing Resistance Tolerances
-
-
Antunano, M.J.1
Baumgardner, F.W.2
Chen, Y.T.3
Constable, S.H.4
-
24
-
-
84893553506
-
The effects of respirator wear on heart rate and blood pressure during moderate steady-state work
-
rd annual Regional National Occupational Research Agenda (NORA) Young/New Investigators Symposium, April, 2005, Salt Lake City, UT. pp 1-10.
-
(2005)
rd Annual Regional National Occupational Research Agenda (NORA) Young/New Investigators Symposium, April, 2005, Salt Lake City, UT
, pp. 1-10
-
-
Bardsley, S.M.1
Amtmann, J.2
Spath, W.K.3
-
25
-
-
0017644219
-
Acceptable levels for the breathing resistance of respiratory apparatus: Results for men over the age of 45
-
Love RG, Muir DCF, Sweetland KF, Bentley RA, Griffin OG (1977) Acceptable levels for the breathing resistance of respiratory apparatus: results for men over the age of 45. Br J Ind Med 34: 126-129. PubMed: 871443. (Pubitemid 8131020)
-
(1977)
British Journal of Industrial Medicine
, vol.34
, Issue.2
, pp. 126-129
-
-
Love, R.G.1
Muir, D.C.F.2
Sweetland, K.F.3
-
26
-
-
84872033100
-
Pulmonary and heart rate responses to wearing N95 filtering facepiece respirators
-
doi:10.1016/S0196-6553(13)01168-1. PubMed: 22944510
-
Kim J-H, Benson SM, Roberge RJ (2013) Pulmonary and heart rate responses to wearing N95 filtering facepiece respirators. Am J Infect Control 41: 24-27. doi:10.1016/S0196-6553(13)01168-1. PubMed: 22944510.
-
(2013)
Am J Infect Control
, vol.41
, pp. 24-27
-
-
Kim, J.-H.1
Benson, S.M.2
Roberge, R.J.3
-
27
-
-
84858059606
-
Physiological adaptation and anaesthesia at high altitude
-
Roy PK (2002) Physiological adaptation and anaesthesia at high altitude. Ind J Anaesth 46: 175-181
-
(2002)
Ind J Anaesth
, vol.46
, pp. 175-181
-
-
Roy, P.K.1
-
28
-
-
84878027160
-
Carbon dioxide rebreathing in respiratory protective devices: Influence of speech and work rate in full-face masks
-
dx/doi.org/ 10.1080/00140139.2013.777128
-
Smith CL, Whitelaw JL, Davies B (2013) Carbon dioxide rebreathing in respiratory protective devices: influence of speech and work rate in full-face masks. Ergonomics dx/doi.org/10.1080/00140139.2013.777128.
-
(2013)
Ergonomics
-
-
Smith, C.L.1
Whitelaw, J.L.2
Davies, B.3
-
30
-
-
0022256247
-
Effect of respiratory apparatus on timing and depth of breathing in man
-
DOI 10.1016/0034-5687(85)90130-6
-
Maxwell DL, Cover D, Hughes JMB (1985) Effect of respiratory apparatus on timing and depth of breathing in man. Respir Physiol 61: 255-264. doi:10.1016/0034-5687(85)90130-6. PubMed: 4048673. (Pubitemid 15024717)
-
(1985)
Respiration Physiology
, vol.61
, Issue.2
, pp. 255-264
-
-
Maxwell, D.L.1
Cover, D.2
Hughes, J.M.B.3
-
31
-
-
0000706618
-
A new method for measuring airway resistance in man using a body plethysmograph: Values in normal subjects and in patients with respiratory disease
-
doi:10.1172/JCI103282. PubMed: 13295397
-
DuBois AB, Botelho SY, Comroe JH Jr (1956) A new method for measuring airway resistance in man using a body plethysmograph: values in normal subjects and in patients with respiratory disease. J Clin Invest 35: 327-335. doi:10.1172/JCI103282. PubMed: 13295397.
-
(1956)
J Clin Invest
, vol.35
, pp. 327-335
-
-
DuBois, A.B.1
Botelho, S.Y.2
Comroe Jr., J.H.3
-
32
-
-
0021046487
-
External inspiratory resistance of protective respiratory devices: Effects on physical performance and respiratory function
-
Lerman Y, Shefer A, Epstein Y, Keren G (1983) External inspiratory resistance of protective respiratory devices: effects on physical performance and respiratory function. Am J Ind Med 4: 733-740. doi:10.1002/ajim.4700040606. PubMed: 6650511. (Pubitemid 14241693)
-
(1983)
American Journal of Industrial Medicine
, vol.4
, Issue.6
, pp. 733-740
-
-
Lerman, Y.1
Shefer, A.2
Epstein, Y.3
Keren, G.4
-
33
-
-
84865018644
-
Thermal burden of N95 filtering facepiece respirators
-
doi:10.1093/annhyg/mes001. PubMed: 22294505
-
Roberge R, Benson S, Kim J-H (2012) Thermal burden of N95 filtering facepiece respirators. Ann Occup Hyg 56: 808-814. doi:10.1093/annhyg/mes001. PubMed: 22294505.
-
(2012)
Ann Occup Hyg
, vol.56
, pp. 808-814
-
-
Roberge, R.1
Benson, S.2
Kim, J.-H.3
-
34
-
-
84863011594
-
Protective facemask impact on human thermoregulation: An overview
-
doi:10.1093/annhyg/mer069. PubMed: 21917820
-
Roberge RJ, Kim J-H, Coca A (2012) Protective facemask impact on human thermoregulation: an overview. Ann Occup Hyg 56: 102-112. doi:10.1093/annhyg/ mer069. PubMed: 21917820.
-
(2012)
Ann Occup Hyg
, vol.56
, pp. 102-112
-
-
Roberge, R.J.1
Kim, J.-H.2
Coca, A.3
-
35
-
-
0000304091
-
Air flow measurement on human subjects with and without respiratory resistance at several work rates
-
Silverman L, Lee G, Plotkin T, Sawyers LA, Yancey AR (1951) Air flow measurement on human subjects with and without respiratory resistance at several work rates. Arch Ind Hyg Occup Med 3: 461-478.
-
(1951)
Arch Ind Hyg Occup Med
, vol.3
, pp. 461-478
-
-
Silverman, L.1
Lee, G.2
Plotkin, T.3
Sawyers, L.A.4
Yancey, A.R.5
-
36
-
-
0013992985
-
Perception of added airflow resistance in humans
-
doi:10.1016/0034-5687(66)90039-9. PubMed: 5971707
-
Wiley RL, Zechman FW Jr (1966/7) Perception of added airflow resistance in humans. Respir Physiol 2: 73-87. doi:10.1016/0034-5687(66)90039-9. PubMed: 5971707.
-
(1966)
Respir Physiol
, vol.2
, pp. 73-87
-
-
Wiley, R.L.1
Zechman Jr., F.W.2
-
37
-
-
0017812693
-
The perception of changes in airflow resistance in normal subjects and patients with chronic airways obstruction
-
Gottfried SB, Altose MD, Kelsen SG, Fogarty CM, Cherniack SM (1978) The perception of changes in airflow resistance in normal subjects and patients with chronic airways obstruction. Chest 73 (Suppl): 286-288. doi:10.1378/chest.73.2- Supplement.286. PubMed: 340163. (Pubitemid 8286290)
-
(1978)
Chest
, vol.73
, Issue.2 SUPPL.
, pp. 286-288
-
-
Gottfried, S.B.1
Altose, M.D.2
Kelsen, S.G.3
-
38
-
-
0019225794
-
Changes in the perception of inspiratory resistive loads during partial curarization
-
Campbell EJM, Gandevia SC, Killian KJ, Mahutte CK, Rigg JRA (1980) Changes in the perception of inspiratory restive loads during partial curarization. J Physiol 309: 93-100. PubMed: 7252883. (Pubitemid 11199928)
-
(1980)
Journal of Physiology
, vol.VOL.309
, pp. 93-100
-
-
Campbell, E.J.M.1
Gandevia, S.C.2
Killian, K.J.3
-
39
-
-
0019271768
-
Effect of timing, flow, lung volume, and threshold pressures on resistive load detection
-
Killian KJ, Mahutte CK, Howell JBL, Campbell EJM (1980) Effect of timing, flow, lung volume, and threshold pressures on restive load detection. Journal of Appl Physiol 49: 958-963. PubMed: 7440304. (Pubitemid 11161186)
-
(1980)
Journal of Applied Physiology Respiratory Environmental and Exercise Physiology
, vol.49
, Issue.6
, pp. 958-963
-
-
Killian, K.J.1
Mahutte, C.K.2
Howell, J.B.L.3
Campbell, E.J.M.4
-
40
-
-
0019363724
-
Effects of added inspiratory loads on load detection thresholds
-
PubMed: 7204184
-
Burki NK (1981) Effects of added inspiratory loads on load detection thresholds. J Appl Physiol Respir Environ Exerc Physiol 50: 162-164. PubMed: 7204184.
-
(1981)
J Appl Physiol Respir Environ Exerc Physiol
, vol.50
, pp. 162-164
-
-
Burki, N.K.1
-
41
-
-
0024386663
-
Relationship of subjective tolerance of respirator loads to physiologic effects and psychophysical load sensitivity
-
Harber P, Shimozaki S, Barrett T, Loisides P (1989) Relationship of subjective tolerance of respirator loads to physiologic effects and psychophysical load sensitivity. J Occup Med 31: 681-686. doi:10.1097/00043764- 198908000-00014. PubMed: 2668457. (Pubitemid 19212789)
-
(1989)
Journal of Occupational Medicine
, vol.31
, Issue.8
, pp. 681-686
-
-
Harber, P.1
Shimozaki, S.2
Barrett, T.3
Loisides, P.4
-
42
-
-
84857694961
-
N95 filtering facepiece respirator deadspace temperature and humidity
-
doi:10.1080/15459624.2012.660428. PubMed: 22413894
-
Roberge RJ, Kim J-H, Benson S (2012) N95 filtering facepiece respirator deadspace temperature and humidity. J Occup Environ Hyg 9: 166-171. doi:10.1080/15459624.2012.660428. PubMed: 22413894.
-
(2012)
J Occup Environ Hyg
, vol.9
, pp. 166-171
-
-
Roberge, R.J.1
Kim, J.-H.2
Benson, S.3
-
43
-
-
0030805515
-
Study of respirator effect on nasal-oral flow partition
-
DOI 10.1002/(SICI)1097-0274(199710)32:4<408::AID-A
-
Harber P, Beck J, Luo J (1997) Study of respirator effect on nasal-oral flow partition. Am J Ind Med 32: 408-412. doi:10.1002/(SICI)1097-0274(199710)32: 4. PubMed: 9258395. (Pubitemid 27330283)
-
(1997)
American Journal of Industrial Medicine
, vol.32
, Issue.4
, pp. 408-412
-
-
Harber, P.1
Beck, J.2
Luo, J.3
-
44
-
-
66849091458
-
Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department
-
PubMed: 19386868
-
McVicar J, Eager R (2009) Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department. Emer Med J 26: 344-346. PubMed: 19386868.
-
(2009)
Emer Med J
, vol.26
, pp. 344-346
-
-
McVicar, J.1
Eager, R.2
-
45
-
-
26444583263
-
2 monitoring in critically ill adults: Clinical evaluation of a new sensor
-
doi:10.1097/01.CCM.0000181734.26070.26. PubMed: 16215371
-
2 monitoring in critically ill adults: clinical evaluation of a new sensor. Crit Care Med 33: 2203-2206. doi:10.1097/01.CCM. 0000181734.26070.26. PubMed: 16215371.
-
(2005)
Crit Care Med
, vol.33
, pp. 2203-2206
-
-
Bendjelid, K.1
Schütz, N.2
Stotz, M.3
Gerard, I.4
Suter, P.M.5
|