메뉴 건너뛰기




Volumn 54, Issue 12, 2013, Pages 2175-2181

New approach to quantification of molecularly targeted radiotracer uptake from hybrid cardiac SPECT/CT: Methodology and validation

Author keywords

CT; Hot spot quantification; Molecular cardiac imaging; Small animal validation; SPECT

Indexed keywords

IOHEXOL; MARACICLATIDE; MARACICLATIDE TC 99M; VITRONECTIN RECEPTOR; TRACER;

EID: 84893383497     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.113.123208     Document Type: Article
Times cited : (10)

References (31)
  • 1
    • 0032580851 scopus 로고    scopus 로고
    • 99mTc-HL91: "Hot spot" detection of ischemic myocardium in vivo by gamma camera imaging
    • Okada RD, Johnson G. 99mTc-HL91: "hot spot" detection of ischemic myocardium in vivo by gamma camera imaging. Circulation. 1998;97:2557-2566.
    • (1998) Circulation. , vol.97 , pp. 2557-2566
    • Okada, R.D.1    Johnson, G.2
  • 2
    • 79952777554 scopus 로고    scopus 로고
    • Accuracy and reproducibility of absolute quantification of myocardial focal tracer uptake from molecular targeted SPECT/ CT: A canine validation
    • Liu YH, Sahul Z, Weyman CA, et al. Accuracy and reproducibility of absolute quantification of myocardial focal tracer uptake from molecular targeted SPECT/ CT: a canine validation. J Nucl Med. 2011;52:453-460.
    • (2011) J Nucl Med. , vol.52 , pp. 453-460
    • Liu, Y.H.1    Sahul, Z.2    Weyman, C.A.3
  • 3
    • 33750424309 scopus 로고    scopus 로고
    • A new method for hot-spot quantification of hybrid SPECT/CT cardiac images: Methodology and preliminary phantom validation
    • Liu YH, Fernando G, Sinusas A. A new method for hot-spot quantification of hybrid SPECT/CT cardiac images: methodology and preliminary phantom validation. IEEE Trans Nucl Sci. 2006;53:2814-2821.
    • (2006) IEEE Trans Nucl Sci. , vol.53 , pp. 2814-2821
    • Liu, Y.H.1    Fernando, G.2    Sinusas, A.3
  • 4
    • 84868032865 scopus 로고    scopus 로고
    • A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology
    • Erlandsson K, Buvat I, Pretorius PH, Thomas BA, Hutton BF. A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology. Phys Med Biol. 2012;57:R119-R159.
    • (2012) Phys Med Biol. , vol.57
    • Erlandsson, K.1    Buvat, I.2    Pretorius, P.H.3    Thomas, B.A.4    Hutton, B.F.5
  • 5
    • 0021261066 scopus 로고
    • Analysis of emission tomographic scan data: Limitations imposed by resolution and background
    • Kessler RM, Ellis JRJ, Eden M. Analysis of emission tomographic scan data: limitations imposed by resolution and background. J Comput Assist Tomogr. 1984;8:514-522.
    • (1984) J Comput Assist Tomogr. , vol.8 , pp. 514-522
    • Kessler, R.M.1    Ellis, J.R.J.2    Eden, M.3
  • 7
    • 0021062116 scopus 로고
    • Measurements of regional tissue and blood-pool radiotracer concentrations from serial tomographic images of the heart
    • Henze E, Huang S, Ratib O, Hoffman E, Phelps M, Schelbert H. Measurements of regional tissue and blood-pool radiotracer concentrations from serial tomographic images of the heart. J Nucl Med. 1983;24:987-996.
    • (1983) J Nucl Med. , vol.24 , pp. 987-996
    • Henze, E.1    Huang, S.2    Ratib, O.3    Hoffman, E.4    Phelps, M.5    Schelbert, H.6
  • 8
    • 0000615384 scopus 로고
    • Measurement of myocardial blood flow with positron mission tomography: Correction for count spillover and partial volume ffects
    • Herrero P, Markham J, Myears DW, Weinheimer CJ, Bergmann SR. Measurement of myocardial blood flow with positron mission tomography: correction for count spillover and partial volume ffects. Math Comput Model. 1988;11:807-812.
    • (1988) Math Comput Model. , vol.11 , pp. 807-812
    • Herrero, P.1    Markham, J.2    Myears, D.W.3    Weinheimer, C.J.4    Bergmann, S.R.5
  • 9
    • 0031684391 scopus 로고    scopus 로고
    • Correction of partial volume effects in myocardial SPECT
    • Hutton BF, Osiecki A. Correction of partial volume effects in myocardial SPECT. J Nucl Cardiol. 1998;5:402-413.
    • (1998) J Nucl Cardiol. , vol.5 , pp. 402-413
    • Hutton, B.F.1    Osiecki, A.2
  • 10
    • 0002345492 scopus 로고    scopus 로고
    • In vivo correction method for partial volume effects in positron emission tomography, accuracy and precision
    • Meyers R, Cunningham V, Bailey D, Jones T, eds. New York, NY: Academic
    • Rousset O, Ma Y, Marenco S, Wong D, Evans A. In vivo correction method for partial volume effects in positron emission tomography, accuracy and precision. In: Meyers R, Cunningham V, Bailey D, Jones T, eds. Quantification of Brain Function using PET. New York, NY: Academic; 1996:158-165.
    • (1996) Quantification of Brain Function Using PET , pp. 158-165
    • Rousset, O.1    Ma, Y.2    Marenco, S.3    Wong, D.4    Evans, A.5
  • 11
    • 0033949698 scopus 로고    scopus 로고
    • Effect of partial volume correction on estimates of the influx and cerebral metabolism of 6-[18F]fluoro-L-dopa stud-ied with PET in normal control and Parkinson's disease subjects
    • Rousset OG, Deep P, Kuwabara H, Evans A, Gjedde A, Cumming P. Effect of partial volume correction on estimates of the influx and cerebral metabolism of 6-[18F]fluoro-L-dopa stud-ied with PET in normal control and Parkinson's disease subjects. Synapse. 2000;37:81-89.
    • (2000) Synapse. , vol.37 , pp. 81-89
    • Rousset, O.G.1    Deep, P.2    Kuwabara, H.3    Evans, A.4    Gjedde, A.5    Cumming, P.6
  • 12
    • 0031955835 scopus 로고    scopus 로고
    • Correction for partial volume effects in PET: Principle and validation
    • Rousset OG, Ma Y, Evans A. Correction for partial volume effects in PET: principle and validation. J Nucl Med. 1998;39:904-911.
    • (1998) J Nucl Med. , vol.39 , pp. 904-911
    • Rousset, O.G.1    Ma, Y.2    Evans, A.3
  • 14
    • 84901403127 scopus 로고
    • 2nd ed. Reading, MA: Addison-Wesley Publishing Company
    • DeGroot MH. Probability and Statistics. 2nd ed. Reading, MA: Addison-Wesley Publishing Company; 1986:100, 263-272.
    • (1986) Probability and Statistics , vol.100 , pp. 263-272
    • Degroot, M.H.1
  • 15
    • 33744806106 scopus 로고    scopus 로고
    • A new method for SPECT quantification of targeted radiotracers uptake in the myocardium
    • Li S, Dobrucki LW, Sinusas AJ, Liu YH. A new method for SPECT quantification of targeted radiotracers uptake in the myocardium. Med Image Comput Comput Assist Interv. 2005;8(Pt 2):684-691.
    • (2005) Med Image Comput Comput Assist Interv. , vol.8 , Issue.PART 2 , pp. 684-691
    • Li, S.1    Dobrucki, L.W.2    Sinusas, A.J.3    Liu, Y.H.4
  • 16
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • Marquardt D. An algorithm for least-squares estimation of nonlinear parameters. J Soc Indust Appl Math. 1963;11:431-441.
    • (1963) J Soc Indust Appl Math. , vol.11 , pp. 431-441
    • Marquardt, D.1
  • 17
    • 0036898673 scopus 로고    scopus 로고
    • Correction of partial-volume effect for PET striatal imaging: Fast implementation and study of robustness
    • Frouin V, Claude C. Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness. J Nucl Med. 2002;43:1715-1726.
    • (2002) J Nucl Med. , vol.43 , pp. 1715-1726
    • Frouin, V.1    Claude, C.2
  • 18
    • 0026010139 scopus 로고
    • SPECT volume quantitation: Influence of spatial resolution, source size and shape, and voxel size
    • King MA, Long D, Brill A. SPECT volume quantitation: influence of spatial resolution, source size and shape, and voxel size. Med Phys. 1991;18:1016-1024.
    • (1991) Med Phys. , vol.18 , pp. 1016-1024
    • King, M.A.1    Long, D.2    Brill, A.3
  • 19
    • 0035004219 scopus 로고    scopus 로고
    • Analysis of FDG uptake with hybrid PET using standardized uptake values
    • Zimny M, Kaiser H-J, Wildberger J, et al. Analysis of FDG uptake with hybrid PET using standardized uptake values. Eur J Nucl Med. 2001;28:586-592.
    • (2001) Eur J Nucl Med. , vol.28 , pp. 586-592
    • Zimny, M.1    Kaiser, H.-J.2    Wildberger, J.3
  • 20
    • 0035114719 scopus 로고    scopus 로고
    • FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection
    • Ramos CD, Erdi YE, Gonen M, et al. FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection. Eur J Nucl Med. 2001;28:155-164.
    • (2001) Eur J Nucl Med. , vol.28 , pp. 155-164
    • Ramos, C.D.1    Erdi, Y.E.2    Gonen, M.3
  • 21
    • 0025845450 scopus 로고
    • The applications of PET in clinical oncology
    • Strauss LG, Conti PS. The applications of PET in clinical oncology. J Nucl Med. 1991;32:623-648.
    • (1991) J Nucl Med. , vol.32 , pp. 623-648
    • Strauss, L.G.1    Conti, P.S.2
  • 22
    • 3543006512 scopus 로고    scopus 로고
    • The prognostic significance of fluorodeoxyglucose positron emission tomography imaging for patients with non-small cell lung carcinoma
    • Ahuja V, Coleman RE, Herndon J, Patz EFJ. The prognostic significance of fluorodeoxyglucose positron emission tomography imaging for patients with non-small cell lung carcinoma. Cancer. 1998;83:918-924.
    • (1998) Cancer. , vol.83 , pp. 918-924
    • Ahuja, V.1    Coleman, R.E.2    Herndon, J.3    Patz, E.F.J.4
  • 23
    • 0025083990 scopus 로고
    • Maximum-likelihood estimation: A mathematical model for quantitation in nuclear medicine
    • Müller SP, Kijewski MF, Moore SC, Holman BL. Maximum-likelihood estimation: a mathematical model for quantitation in nuclear medicine. J Nucl Med. 1990;31:1693-1701.
    • (1990) J Nucl Med. , vol.31 , pp. 1693-1701
    • Müller, S.P.1    Kijewski, M.F.2    Moore, S.C.3    Holman, B.L.4
  • 24
    • 0018983328 scopus 로고
    • Physical factors affecting quantitative measurements using camera-based single photon emission computed tomography (SPECT)
    • Jaszczak RJ, Coleman RE. Whitehead. FR. Physical factors affecting quantitative measurements using camera-based single photon emission computed tomography (SPECT). IEEE Trans Nucl Sci. 1981;28:69-80.
    • (1981) IEEE Trans Nucl Sci. , vol.28 , pp. 69-80
    • Jaszczak, R.J.1    Coleman, R.E.2    Whitehead, F.R.3
  • 25
    • 0028851359 scopus 로고
    • Evaluation of SPECT quantification of radiopharmaceutical distribution in canine myocardium
    • Li J, Jaszczak RJ, Greer KL, Gilland DR, DeLong DM, Coleman RE. Evaluation of SPECT quantification of radiopharmaceutical distribution in canine myocardium. J Nucl Med. 1995;36:278-286.
    • (1995) J Nucl Med. , vol.36 , pp. 278-286
    • Li, J.1    Jaszczak, R.J.2    Greer, K.L.3    Gilland, D.R.4    Delong, D.M.5    Coleman, R.E.6
  • 27
    • 0035014978 scopus 로고    scopus 로고
    • Absolute quantification of regional myocardial uptake of 99m-Tc-sestamibi with SPECT: Experimental validation in a porcine model
    • Da Silva AJ, Tang HR, Wong KH, Wu MC, Dae MW, Hasegawa BH. Absolute quantification of regional myocardial uptake of 99m-Tc-sestamibi with SPECT: experimental validation in a porcine model. J Nucl Med. 2001;42:772-779.
    • (2001) J Nucl Med. , vol.42 , pp. 772-779
    • Da Silva, A.J.1    Tang, H.R.2    Wong, K.H.3    Wu, M.C.4    Dae, M.W.5    Hasegawa, B.H.6
  • 29
    • 58149125644 scopus 로고    scopus 로고
    • Diminishing the impact of the partial volume effect in cardiac SPECT perfusion imaging
    • Pretorius PH, King M. Diminishing the impact of the partial volume effect in cardiac SPECT perfusion imaging. Med Phys. 2009;36:105-115.
    • (2009) Med Phys. , vol.36 , pp. 105-115
    • Pretorius, P.H.1    King, M.2
  • 30
    • 0022536597 scopus 로고
    • A maximum likelihood method for region-of-interest evaluation in emission tomography
    • Carson RE. A maximum likelihood method for region-of-interest evaluation in emission tomography. J Comput Assist Tomogr. 1986;10:654-663.
    • (1986) J Comput Assist Tomogr. , vol.10 , pp. 654-663
    • Carson, R.E.1
  • 31
    • 0019965099 scopus 로고
    • Regional distribution of myocardial blood flow measured by single- photon emission tomography: Comparison with in vitro counting
    • Caldwell JH, Williams DL, Hamilton GW, et al. Regional distribution of myocardial blood flow measured by single- photon emission tomography: comparison with in vitro counting. J Nucl Med. 1982;23:490-495.
    • (1982) J Nucl Med. , vol.23 , pp. 490-495
    • Caldwell, J.H.1    Williams, D.L.2    Hamilton, G.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.