메뉴 건너뛰기




Volumn 12, Issue 1, 2014, Pages

TEG® and RapidTEG® are unreliable for detecting warfarin-coagulopathy: A prospective cohort study

Author keywords

Coagulopathy; Thromboelastography; Warfarin

Indexed keywords


EID: 84893195156     PISSN: None     EISSN: 14779560     Source Type: Journal    
DOI: 10.1186/1477-9560-12-4     Document Type: Article
Times cited : (51)

References (11)
  • 1
    • 34447306023 scopus 로고    scopus 로고
    • Bleeding complications with warfarin use: a prevalent adverse effect resulting in regulatory action
    • 10.1001/archinte.167.13.1414, 17620536
    • Wysowski DK, Nourjah P, Swartz L. Bleeding complications with warfarin use: a prevalent adverse effect resulting in regulatory action. Arch Intern Med 2007, 167(13):1414-1419. 10.1001/archinte.167.13.1414, 17620536.
    • (2007) Arch Intern Med , vol.167 , Issue.13 , pp. 1414-1419
    • Wysowski, D.K.1    Nourjah, P.2    Swartz, L.3
  • 2
    • 79956000550 scopus 로고    scopus 로고
    • Prevalence and implications of preinjury warfarin use: an analysis of the National Trauma Databank
    • Dossett LA, Riesel JN, Griffin MR, Cotton BA. Prevalence and implications of preinjury warfarin use: an analysis of the National Trauma Databank. Arch surg (Chic, Ill : 1960) 2011, 146(5):565-570.
    • (2011) Arch surg (Chic, Ill : 1960) , vol.146 , Issue.5 , pp. 565-570
    • Dossett, L.A.1    Riesel, J.N.2    Griffin, M.R.3    Cotton, B.A.4
  • 3
    • 42449112966 scopus 로고    scopus 로고
    • Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices
    • 10.1213/ane.0b013e318168b367, 18420846
    • Ganter MT, Hofer CK. Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices. Anesth Analg 2008, 106(5):1366-1375. 10.1213/ane.0b013e318168b367, 18420846.
    • (2008) Anesth Analg , vol.106 , Issue.5 , pp. 1366-1375
    • Ganter, M.T.1    Hofer, C.K.2
  • 4
    • 67651044054 scopus 로고    scopus 로고
    • Possibilities and limitations of thrombelastometry/thromboelastography
    • Lang T, von Depka M. Possibilities and limitations of thrombelastometry/thromboelastography. Hamostaseologie 2006, 26(Suppl 1):S21-S29.
    • (2006) Hamostaseologie , vol.26 , Issue.SUPPL. 1
    • Lang, T.1    von Depka, M.2
  • 5
    • 82955247833 scopus 로고    scopus 로고
    • Principles and practice of thromboelastography in clinical coagulation management and transfusion practice
    • 10.1016/j.tmrv.2011.07.005, 21872428
    • Bolliger D, Seeberger MD, Tanaka KA. Principles and practice of thromboelastography in clinical coagulation management and transfusion practice. Transfus Med Rev 2012, 26(1):1-13. 10.1016/j.tmrv.2011.07.005, 21872428.
    • (2012) Transfus Med Rev , vol.26 , Issue.1 , pp. 1-13
    • Bolliger, D.1    Seeberger, M.D.2    Tanaka, K.A.3
  • 6
    • 78049244568 scopus 로고    scopus 로고
    • Critical factors contributing to the thromboelastography trace
    • 10.1055/s-0030-1265288, 20978992
    • MacDonald SG, Luddington RJ. Critical factors contributing to the thromboelastography trace. Semin Thromb Hemost 2010, 36(7):712-722. 10.1055/s-0030-1265288, 20978992.
    • (2010) Semin Thromb Hemost , vol.36 , Issue.7 , pp. 712-722
    • MacDonald, S.G.1    Luddington, R.J.2
  • 7
    • 68249146371 scopus 로고    scopus 로고
    • Global hemostasis testing thromboelastography: old technology, new applications
    • 10.1016/j.cll.2009.04.003, 19665684
    • Chen A, Teruya J. Global hemostasis testing thromboelastography: old technology, new applications. Clin Lab Med 2009, 29(2):391-407. 10.1016/j.cll.2009.04.003, 19665684.
    • (2009) Clin Lab Med , vol.29 , Issue.2 , pp. 391-407
    • Chen, A.1    Teruya, J.2
  • 8
    • 77952582921 scopus 로고    scopus 로고
    • In vitro comparative study of hemostatic components in warfarin-treated and fibrinogen-deficient plasma
    • 10.1053/j.jvca.2009.07.012, 19819728
    • Rumph B, Bolliger D, Narang N, Molinaro RJ, Levy JH, Szlam F, Tanaka KA. In vitro comparative study of hemostatic components in warfarin-treated and fibrinogen-deficient plasma. J Cardiothorac Vasc Anesth 2010, 24(3):408-412. 10.1053/j.jvca.2009.07.012, 19819728.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , Issue.3 , pp. 408-412
    • Rumph, B.1    Bolliger, D.2    Narang, N.3    Molinaro, R.J.4    Levy, J.H.5    Szlam, F.6    Tanaka, K.A.7
  • 9
    • 84855348619 scopus 로고    scopus 로고
    • Vitamin K-dependent coagulation factor deficiency in trauma: a comparative analysis between international normalized ratio and thromboelastography
    • 10.1111/j.1537-2995.2011.03237.x, 21745216
    • Nascimento B, Al Mahoos M, Callum J, Capone A, Pacher J, Tien H, Rizoli S. Vitamin K-dependent coagulation factor deficiency in trauma: a comparative analysis between international normalized ratio and thromboelastography. Transfusion 2012, 52(1):7-13. 10.1111/j.1537-2995.2011.03237.x, 21745216.
    • (2012) Transfusion , vol.52 , Issue.1 , pp. 7-13
    • Nascimento, B.1    Al Mahoos, M.2    Callum, J.3    Capone, A.4    Pacher, J.5    Tien, H.6    Rizoli, S.7
  • 10
    • 0036710580 scopus 로고    scopus 로고
    • Coagulation status using thromboelastography in patients receiving warfarin prophylaxis and epidural analgesia
    • 10.1016/S0952-8180(02)00373-2, 12393106
    • Hepner DL, Concepcion M, Bhavani-Shankar K. Coagulation status using thromboelastography in patients receiving warfarin prophylaxis and epidural analgesia. J Clin Anesth 2002, 14(6):405-410. 10.1016/S0952-8180(02)00373-2, 12393106.
    • (2002) J Clin Anesth , vol.14 , Issue.6 , pp. 405-410
    • Hepner, D.L.1    Concepcion, M.2    Bhavani-Shankar, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.