메뉴 건너뛰기




Volumn 38, Issue 1, 2014, Pages 47-53

Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation

Author keywords

Biomechanics; Cadaver; Fixation; Periprosthetic; Vancouver B1 fracture

Indexed keywords

AGED; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE PLATE; CADAVER; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FEMUR FRACTURE; FRACTURE FIXATION; HUMAN; MALE; OSTEOSYNTHESIS; PERIPROSTHETIC FRACTURE; PRIORITY JOURNAL; PROSTHESIS FIXATION; RIGIDITY; TOTAL HIP PROSTHESIS; VERY ELDERLY;

EID: 84893185298     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-013-2113-0     Document Type: Article
Times cited : (40)

References (23)
  • 1
    • 31144454517 scopus 로고    scopus 로고
    • Risk factors for failure after treatment of a periprosthetic fracture of the femur
    • 1:STN:280:DC%2BD2MnnslejsQ%3D%3D 16365115 10.1302/0301-620X.88B1.17029
    • Lindahl H, Malchau H, Oden A, Garellick G (2006) Risk factors for failure after treatment of a periprosthetic fracture of the femur. J Bone Joint Surg Br 88(1):26-30
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.1 , pp. 26-30
    • Lindahl, H.1    Malchau, H.2    Oden, A.3    Garellick, G.4
  • 2
    • 78651244598 scopus 로고    scopus 로고
    • The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement
    • 1:STN:280:DC%2BC3M%2FotVGhuw%3D%3D 21196551 10.1302/0301-620X.93B1.25087
    • Meek RM, Norwood T, Smith R, Brenkel IJ, Howie CR (2011) The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement. J Bone Joint Surg Br 93(1):96-101
    • (2011) J Bone Joint Surg Br , vol.93 , Issue.1 , pp. 96-101
    • Meek, R.M.1    Norwood, T.2    Smith, R.3    Brenkel, I.J.4    Howie, C.R.5
  • 3
    • 34248162402 scopus 로고    scopus 로고
    • Epidemiology of periprosthetic femur fracture around a total hip arthroplasty
    • 17477925 10.1016/j.injury.2007.02.048
    • Lindahl H (2007) Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury 38(6):651-654
    • (2007) Injury , vol.38 , Issue.6 , pp. 651-654
    • Lindahl, H.1
  • 4
    • 0031613038 scopus 로고    scopus 로고
    • Periprosthetic fractures of the femur: Principles of prevention and management
    • 1:STN:280:DyaK1c3jt12itw%3D%3D 9571424
    • Garbuz DS, Masri BA, Duncan CP (1998) Periprosthetic fractures of the femur: principles of prevention and management. Instr Course Lect 47:237-242
    • (1998) Instr Course Lect , vol.47 , pp. 237-242
    • Garbuz, D.S.1    Masri, B.A.2    Duncan, C.P.3
  • 5
    • 71949113190 scopus 로고    scopus 로고
    • Principles of treatment for periprosthetic femoral shaft fractures around well-fixed total hip arthroplasty
    • 19880678
    • Pike J, Davidson D, Garbuz D, Duncan CP, O'Brien PJ, Masri BA (2009) Principles of treatment for periprosthetic femoral shaft fractures around well-fixed total hip arthroplasty. J Am Acad Orthop Surg 17(11):677-688
    • (2009) J Am Acad Orthop Surg , vol.17 , Issue.11 , pp. 677-688
    • Pike, J.1    Davidson, D.2    Garbuz, D.3    Duncan, C.P.4    O'Brien, P.J.5    Masri, B.A.6
  • 6
    • 34248397244 scopus 로고    scopus 로고
    • Principles of internal fixation and selection of implants for periprosthetic femoral fractures
    • 17467709 10.1016/j.injury.2007.02.050
    • Giannoudis PV, Kanakaris NK, Tsiridis E (2007) Principles of internal fixation and selection of implants for periprosthetic femoral fractures. Injury 38(6):669-687
    • (2007) Injury , vol.38 , Issue.6 , pp. 669-687
    • Giannoudis, P.V.1    Kanakaris, N.K.2    Tsiridis, E.3
  • 7
    • 78149358374 scopus 로고    scopus 로고
    • Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: Biomechanical comparison studies on cadaveric bones
    • 1:STN:280:DC%2BC3M7msVGmsw%3D%3D 21288467 10.1016/j.injury.2010.05.007
    • Konstantinidis L, Hauschild O, Beckmann NA, Hirschmuller A, Sudkamp NP, Helwig P (2010) Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: biomechanical comparison studies on cadaveric bones. Injury 41(12):1256-1261
    • (2010) Injury , vol.41 , Issue.12 , pp. 1256-1261
    • Konstantinidis, L.1    Hauschild, O.2    Beckmann, N.A.3    Hirschmuller, A.4    Sudkamp, N.P.5    Helwig, P.6
  • 8
    • 77954774700 scopus 로고    scopus 로고
    • The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty
    • 2914750 20653962 10.1186/1749-799X-5-45
    • Lever JP, Zdero R, Nousiainen MT, Waddell JP, Schemitsch EH (2010) The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty. J Orthop Surg Res 5:45
    • (2010) J Orthop Surg Res , vol.5 , pp. 45
    • Lever, J.P.1    Zdero, R.2    Nousiainen, M.T.3    Waddell, J.P.4    Schemitsch, E.H.5
  • 9
    • 84993813723 scopus 로고    scopus 로고
    • Biomechanical comparison of 2 different locking plate fixation methods in Vancouver b1 periprosthetic femur fractures
    • 3597304 23569670 10.1177/2151458510397609
    • Pletka JD, Marsland D, Belkoff SM, Mears SC, Kates SL (2011) Biomechanical comparison of 2 different locking plate fixation methods in Vancouver b1 periprosthetic femur fractures. Geriatr Orthop Surg Rehabil 2(2):51-55
    • (2011) Geriatr Orthop Surg Rehabil , vol.2 , Issue.2 , pp. 51-55
    • Pletka, J.D.1    Marsland, D.2    Belkoff, S.M.3    Mears, S.C.4    Kates, S.L.5
  • 10
    • 84859927172 scopus 로고    scopus 로고
    • A biomechanical comparison of periprosthetic femoral fracture fixation in normal and osteoporotic cadaveric bone
    • 22014657 10.1016/j.arth.2011.08.019
    • Demos HA, Briones MS, White PH, Hogan KA, Barfield WR (2012) A biomechanical comparison of periprosthetic femoral fracture fixation in normal and osteoporotic cadaveric bone. J Arthroplasty 27(5):783-788
    • (2012) J Arthroplasty , vol.27 , Issue.5 , pp. 783-788
    • Demos, H.A.1    Briones, M.S.2    White, P.H.3    Hogan, K.A.4    Barfield, W.R.5
  • 11
    • 0034049783 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: A biomechanical study of 5 techniques
    • 1:STN:280:DC%2BD3M%2Fks1Cgsw%3D%3D 10884215 10.1054/arth.2000.4339
    • Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE (2000) Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 15(4):523-528
    • (2000) J Arthroplasty , vol.15 , Issue.4 , pp. 523-528
    • Dennis, M.G.1    Simon, J.A.2    Kummer, F.J.3    Koval, K.J.4    Dicesare, P.E.5
  • 13
    • 70350634217 scopus 로고    scopus 로고
    • An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component
    • 1:STN:280:DC%2BD1MjjtFajtw%3D%3D 19880884 10.1302/0301-620X.91B11.22292
    • Corten K, Vanrykel F, Bellemans J, Frederix PR, Simon JP, Broos PL (2009) An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component. J Bone Joint Surg Br 91(11):1424-1430
    • (2009) J Bone Joint Surg Br , vol.91 , Issue.11 , pp. 1424-1430
    • Corten, K.1    Vanrykel, F.2    Bellemans, J.3    Frederix, P.R.4    Simon, J.P.5    Broos, P.L.6
  • 14
    • 79958074209 scopus 로고    scopus 로고
    • Distal femur fractures of the elderly-different treatment options in a biomechanical comparison
    • 20951378 10.1016/j.injury.2010.09.009
    • Wahnert D, Hoffmeier K, Frober R, Hofmann GO, Muckley T (2011) Distal femur fractures of the elderly-different treatment options in a biomechanical comparison. Injury 42(7):655-659
    • (2011) Injury , vol.42 , Issue.7 , pp. 655-659
    • Wahnert, D.1    Hoffmeier, K.2    Frober, R.3    Hofmann, G.O.4    Muckley, T.5
  • 15
    • 84877771917 scopus 로고    scopus 로고
    • The potential of implant augmentation in the treatment of osteoporotic distal femur fractures: A biomechanical study
    • 1:STN:280:DC%2BC38bptFamug%3D%3D 23000049 10.1016/j.injury.2012.08.053
    • Wahnert D, Lange JH, Schulze M, Lenschow S, Stange R, Raschke MJ (2013) The potential of implant augmentation in the treatment of osteoporotic distal femur fractures: a biomechanical study. Injury 44(6):808-812
    • (2013) Injury , vol.44 , Issue.6 , pp. 808-812
    • Wahnert, D.1    Lange, J.H.2    Schulze, M.3    Lenschow, S.4    Stange, R.5    Raschke, M.J.6
  • 16
    • 35448972107 scopus 로고    scopus 로고
    • Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures
    • 1:STN:280:DC%2BD2srhsleitw%3D%3D 17768193 10.2106/JBJS.F.01224
    • Buttaro MA, Farfalli G, Paredes Nunez M, Comba F, Piccaluga F (2007) Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am 89(9):1964-1969
    • (2007) J Bone Joint Surg Am , vol.89 , Issue.9 , pp. 1964-1969
    • Buttaro, M.A.1    Farfalli, G.2    Paredes Nunez, M.3    Comba, F.4    Piccaluga, F.5
  • 17
    • 41149107570 scopus 로고    scopus 로고
    • Treatment of periprosthetic femur fractures with the non-contact bridging plate: A new angular stable implant
    • 1:STN:280:DC%2BD1c7ovVOisA%3D%3D 17639435 10.1007/s00402-007-0396-6
    • Erhardt JB, Grob K, Roderer G, Hoffmann A, Forster TN, Kuster MS (2008) Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant. Arch Orthop Trauma Surg 128(4):409-416
    • (2008) Arch Orthop Trauma Surg , vol.128 , Issue.4 , pp. 409-416
    • Erhardt, J.B.1    Grob, K.2    Roderer, G.3    Hoffmann, A.4    Forster, T.N.5    Kuster, M.S.6
  • 18
    • 84866676232 scopus 로고    scopus 로고
    • The locking attachment plate for proximal fixation of periprosthetic femur fractures - A biomechanical comparison of two techniques
    • 3427437 22638607 10.1007/s00264-012-1574-x
    • Lenz M, Windolf M, Muckley T, Hofmann GO, Wagner M, Richards RG, Schwieger K, Gueorguiev B (2012) The locking attachment plate for proximal fixation of periprosthetic femur fractures - a biomechanical comparison of two techniques. Int Orthop 36(9):1915-1921
    • (2012) Int Orthop , vol.36 , Issue.9 , pp. 1915-1921
    • Lenz, M.1    Windolf, M.2    Muckley, T.3    Hofmann, G.O.4    Wagner, M.5    Richards, R.G.6    Schwieger, K.7    Gueorguiev, B.8
  • 20
    • 84872800002 scopus 로고    scopus 로고
    • Less invasive polyaxial locking plate fixation in periprosthetic and peri-implant fractures of the femur - A prospective study of 41 patients
    • 23219240 10.1016/j.injury.2012.10.035
    • Ruchholtz S, El-Zayat B, Kreslo D, Bucking B, Lewan U, Kruger A, Zettl R (2013) Less invasive polyaxial locking plate fixation in periprosthetic and peri-implant fractures of the femur - A prospective study of 41 patients. Injury 44(2):239-248
    • (2013) Injury , vol.44 , Issue.2 , pp. 239-248
    • Ruchholtz, S.1    El-Zayat, B.2    Kreslo, D.3    Bucking, B.4    Lewan, U.5    Kruger, A.6    Zettl, R.7
  • 21
    • 84884289165 scopus 로고    scopus 로고
    • Blauth M (2013) Minimally invasive periprosthetic plate osteosynthesis using the locking attachment plate
    • 1:STN:280:DC%2BC3sjlsV2mtA%3D%3D 23801040 10.1007/s00064-011-0091-1
    • Kammerlander C, Kates SL, Wagner M, Roth T (2013) Blauth M (2013) Minimally invasive periprosthetic plate osteosynthesis using the locking attachment plate. Oper Orthop Traumatol 25(4):398-410
    • (2013) Oper Orthop Traumatol , vol.25 , Issue.4 , pp. 398-410
    • Kammerlander, C.1    Kates, S.L.2    Wagner, M.3    Roth, T.4
  • 22
    • 79952113449 scopus 로고    scopus 로고
    • The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures
    • 20558031 10.1016/j.arth.2010.04.009
    • Choi JK, Gardner TR, Yoon E, Morrison TA, Macaulay WB, Geller JA (2010) The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures. J Arthroplasty 25(6 Suppl):124-128
    • (2010) J Arthroplasty , vol.25 , Issue.6 SUPPL. , pp. 124-128
    • Choi, J.K.1    Gardner, T.R.2    Yoon, E.3    Morrison, T.A.4    Macaulay, W.B.5    Geller, J.A.6
  • 23
    • 0037315541 scopus 로고    scopus 로고
    • Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system. A ten to thirteen-year follow-up study
    • 12571308
    • Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M (2003) Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 85-A(2):296-303
    • (2003) J Bone Joint Surg Am , vol.85 , Issue.2 , pp. 296-303
    • Garcia-Cimbrelo, E.1    Cruz-Pardos, A.2    Madero, R.3    Ortega-Andreu, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.