메뉴 건너뛰기




Volumn 9, Issue 1, 2014, Pages

Percutaneous closure of a prosthetic pulmonary paravalvular leak

Author keywords

Adult Congenital Heart Disease; Bioprosthetic Paravalvular Leak; Muscular VSD Occluder Device; Right Ventricular Dilation

Indexed keywords

CEFAZOLIN;

EID: 84892896581     PISSN: 1747079X     EISSN: 17470803     Source Type: Journal    
DOI: 10.1111/chd.12058     Document Type: Article
Times cited : (12)

References (11)
  • 1
    • 0025873901 scopus 로고
    • Paraprosthetic leak: a complication of cardiac valve replacement
    • Jindani A, Neville EM, Venn G, etal. Paraprosthetic leak: a complication of cardiac valve replacement. J Cardiovasc Surg (Torino). 1991;32:503-508.
    • (1991) J Cardiovasc Surg (Torino) , vol.32 , pp. 503-508
    • Jindani, A.1    Neville, E.M.2    Venn, G.3
  • 3
    • 34249995406 scopus 로고    scopus 로고
    • Percutaneous closure of perivalvular leaks with Amplatzer occluders: feasibility, safety, and short term results
    • Shapira Y, Hirsch R, Kornowski R, etal. Percutaneous closure of perivalvular leaks with Amplatzer occluders: feasibility, safety, and short term results. J Heart Valve Dis. 2007;16:305-313.
    • (2007) J Heart Valve Dis , vol.16 , pp. 305-313
    • Shapira, Y.1    Hirsch, R.2    Kornowski, R.3
  • 4
    • 41749089801 scopus 로고    scopus 로고
    • Percutaneous closure of perivalvular mitral regurgitation with an Amplatzer occluder device in a patient with both prosthetic mitral and aortic valves
    • Lasorda DM, Mohsin JC. Percutaneous closure of perivalvular mitral regurgitation with an Amplatzer occluder device in a patient with both prosthetic mitral and aortic valves. J Interv Cardiol. 2008;21:190-195.
    • (2008) J Interv Cardiol , vol.21 , pp. 190-195
    • Lasorda, D.M.1    Mohsin, J.C.2
  • 5
    • 0034791874 scopus 로고    scopus 로고
    • Closure of prosthetic paravalvular mitral regurgitation with the Gianturco-Grifka vascular occlusion device
    • Eisenhauer AC, Piemonte TC, Watson PS. Closure of prosthetic paravalvular mitral regurgitation with the Gianturco-Grifka vascular occlusion device. Catheter Cardiovasc Interv. 2001;54:234-238.
    • (2001) Catheter Cardiovasc Interv , vol.54 , pp. 234-238
    • Eisenhauer, A.C.1    Piemonte, T.C.2    Watson, P.S.3
  • 6
    • 0036265934 scopus 로고    scopus 로고
    • [Percutaneous closure of a paravalvular mitral regurgitation with Amplatzer and coil prostheses]
    • Boudjemline Y, Abdel-Massih T, Bonhoeffer P, etal. [Percutaneous closure of a paravalvular mitral regurgitation with Amplatzer and coil prostheses]. Arch Mal Coeur Vaiss. 2002;95:483-486.
    • (2002) Arch Mal Coeur Vaiss , vol.95 , pp. 483-486
    • Boudjemline, Y.1    Abdel-Massih, T.2    Bonhoeffer, P.3
  • 7
    • 10744230047 scopus 로고    scopus 로고
    • Catheter-based approach to mitral regurgitation
    • Condado JA, Velez-Gimon M. Catheter-based approach to mitral regurgitation. J Interv Cardiol. 2003;16:523-534.
    • (2003) J Interv Cardiol , vol.16 , pp. 523-534
    • Condado, J.A.1    Velez-Gimon, M.2
  • 9
    • 77951746987 scopus 로고    scopus 로고
    • Mechanical valve dysfunction after percutaneous perimitral leak closure: salvage by percutaneous occluder retrieval
    • Brilakis ES, Collins LJ, Obel O, Banerjee S. Mechanical valve dysfunction after percutaneous perimitral leak closure: salvage by percutaneous occluder retrieval. Catheter Cardiovasc Interv. 2010;75:876-881.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 876-881
    • Brilakis, E.S.1    Collins, L.J.2    Obel, O.3    Banerjee, S.4
  • 10
    • 33845203994 scopus 로고    scopus 로고
    • Transcatheter closure of paravalvular mitral prosthetic leak with resultant hemolysis
    • Sivakumar K, Shahani J. Transcatheter closure of paravalvular mitral prosthetic leak with resultant hemolysis. Int J Cardiol. 2007;115:e39-e40.
    • (2007) Int J Cardiol , vol.115
    • Sivakumar, K.1    Shahani, J.2
  • 11
    • 33847247910 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Late device dislodgement after percutaneous closure of mitral prosthesis paravalvular leak with Amplatzer muscular ventricular septal defect occluder
    • Ussia GP, Scandura S, Calafiore AM, etal. Images in cardiovascular medicine. Late device dislodgement after percutaneous closure of mitral prosthesis paravalvular leak with Amplatzer muscular ventricular septal defect occluder. Circulation. 2007;115:e208-e210.
    • (2007) Circulation , vol.115
    • Ussia, G.P.1    Scandura, S.2    Calafiore, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.