메뉴 건너뛰기




Volumn 65, Issue , 2014, Pages 2-6

The quantitative evaluation of design parameter's effects on a ground source heat pump system

Author keywords

COP; Ground source heat pump; Operating parameter; Optimal design

Indexed keywords

COP; HEAT TRANSFER RESISTANCE; OPERATING PARAMETERS; OPTIMAL DESIGN; QUANTITATIVE EVALUATION; RENEWABLE ENERGY SYSTEMS; RENEWABLE ENERGY TECHNOLOGIES; THERMAL INTERFERENCES;

EID: 84892821653     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2013.06.034     Document Type: Article
Times cited : (33)

References (21)
  • 1
    • 84868573107 scopus 로고    scopus 로고
    • Current status of the performance of GSHP (ground source heat pump) units in the Republic of Korea
    • Aikins K.A., Choi J.M. Current status of the performance of GSHP (ground source heat pump) units in the Republic of Korea. Energy 2012, 47:77-82.
    • (2012) Energy , vol.47 , pp. 77-82
    • Aikins, K.A.1    Choi, J.M.2
  • 5
    • 84892817327 scopus 로고    scopus 로고
    • IEA, European Geothermal Energy Council, France
    • IEA Geothermal energy 12th annual report 2008, European Geothermal Energy Council, France.
    • (2008) Geothermal energy 12th annual report
  • 6
    • 33846473699 scopus 로고    scopus 로고
    • Three-year operation experience of a ground source heat pump system in Northern Greece
    • Michopoulos A., Bozis D., Kikidis P., Papakostas K., Kyriakis N.A. Three-year operation experience of a ground source heat pump system in Northern Greece. Energy Build 2007, 39:328-334.
    • (2007) Energy Build , vol.39 , pp. 328-334
    • Michopoulos, A.1    Bozis, D.2    Kikidis, P.3    Papakostas, K.4    Kyriakis, N.A.5
  • 7
    • 0037332319 scopus 로고    scopus 로고
    • Experimental study of a closed loop vertical ground source heat pump system
    • Hepbasli A., Akdemir O., Hancioglu E. Experimental study of a closed loop vertical ground source heat pump system. Energy Conversion Management 2003, 44:527-548.
    • (2003) Energy Conversion Management , vol.44 , pp. 527-548
    • Hepbasli, A.1    Akdemir, O.2    Hancioglu, E.3
  • 8
    • 0036462273 scopus 로고    scopus 로고
    • Ground heat exchanger temperature distribution analysis and experimental verification
    • Bi Y., Chen L., Wu C. Ground heat exchanger temperature distribution analysis and experimental verification. Applied Thermal Engineering 2002, 22:183-189.
    • (2002) Applied Thermal Engineering , vol.22 , pp. 183-189
    • Bi, Y.1    Chen, L.2    Wu, C.3
  • 9
    • 32344438517 scopus 로고    scopus 로고
    • Technoeconomic appraisal of a ground source heat pump system for a heating season in eastern Turkey
    • Esen M., Inall M., Esen H. Technoeconomic appraisal of a ground source heat pump system for a heating season in eastern Turkey. Energy Conversion and Management 2006, 47:1281-1298.
    • (2006) Energy Conversion and Management , vol.47 , pp. 1281-1298
    • Esen, M.1    Inall, M.2    Esen, H.3
  • 10
    • 84855525005 scopus 로고    scopus 로고
    • Astudy on completion and configuration of heat exchange wells in ground-coupled heat pump systems with ground water flow
    • Fujii H. Astudy on completion and configuration of heat exchange wells in ground-coupled heat pump systems with ground water flow. Journal of Geothemal Science 2002, 26:143-148.
    • (2002) Journal of Geothemal Science , vol.26 , pp. 143-148
    • Fujii, H.1
  • 11
    • 38949171729 scopus 로고    scopus 로고
    • Numerical analysis and experimental validation of heat transfer in ground heat exchangers in alternative operation modes
    • Cui P., Yang H., Fang Z. Numerical analysis and experimental validation of heat transfer in ground heat exchangers in alternative operation modes. Energy and Buildings 2008, 40:1060-1066.
    • (2008) Energy and Buildings , vol.40 , pp. 1060-1066
    • Cui, P.1    Yang, H.2    Fang, Z.3
  • 12
    • 84855535909 scopus 로고    scopus 로고
    • Design and performance study of the ground-coupled heat pump system with an operating parameter
    • Chung J.T., Choi J.M. Design and performance study of the ground-coupled heat pump system with an operating parameter. Renewable Energy 2012, 42:118-124.
    • (2012) Renewable Energy , vol.42 , pp. 118-124
    • Chung, J.T.1    Choi, J.M.2
  • 16
    • 84892816103 scopus 로고    scopus 로고
    • http://www.wilo.co.kr.
  • 20
    • 84892818487 scopus 로고    scopus 로고
    • Astudy of the effect of borehole thermal resistance on the borehole length
    • Lee S.K., Woo J.S. Astudy of the effect of borehole thermal resistance on the borehole length. Journal of the Korean Solar Energy Society 2009, 29/5:20-27.
    • (2009) Journal of the Korean Solar Energy Society , pp. 20-27
    • Lee, S.K.1    Woo, J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.