In vitro and in vivo three-dimensional velocity vector measurement by three-beam spectral-domain doppler optical coherence tomography

Author keywords

Doppler; flow measurement; multibeam; optical coherence tomography; retina

Indexed keywords

BLOOD FLOW MEASUREMENT; DOPPLER; DOPPLER OPTICAL COHERENCE TOMOGRAPHY; MULTIBEAMS; RETINA; SPATIAL ORIENTATIONS; THREE-DIMENSIONAL VELOCITY; VELOCITY COMPONENTS;

EID: 84892589871     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.JBO.18.11.116010     Document Type: Article
Times cited : (61)

References (50)
  • 2
    • 0037293537 scopus 로고    scopus 로고
    • Optical coherence tomography-principles and applications
    • A. F. Fercher et al., "Optical coherence tomography-principles and applications," Rep. Prog. Phys. 66(2), 239-303 (2003).
    • (2003) Rep. Prog. Phys. , vol.66 , Issue.2 , pp. 239-303
    • Fercher, A.F.1
  • 4
    • 38649091069 scopus 로고    scopus 로고
    • State-Of-The-Art retinal optical coherence tomography
    • DOI 10.1016/j.preteyeres.2007.07.005, PII S1350946207000444
    • W. Drexler and J. G. Fujimoto, "State-of-the-art retinal optical coherence tomography," Prog. Retinal Eye Res. 27(1), 45-88 (2008). (Pubitemid 351165776)
    • (2008) Progress in Retinal and Eye Research , vol.27 , Issue.1 , pp. 45-88
    • Drexler, W.1    Fujimoto, J.G.2
  • 5
    • 79251481152 scopus 로고    scopus 로고
    • Retinal optical coherence tomography: Past, present and future perspectives
    • W. Geitzenauer, C. K. Hitzenberger, and U. M. Schmidt-Erfurth, "Retinal optical coherence tomography: past, present and future perspectives," Br. J. Ophthalmol. 95(2), 171-177 (2011).
    • (2011) Br. J. Ophthalmol. , vol.95 , Issue.2 , pp. 171-177
    • Geitzenauer, W.1    Hitzenberger, C.K.2    Schmidt-Erfurth, U.M.3
  • 6
    • 84975582308 scopus 로고
    • Characterization of fluidflow velocity by optical Doppler tomography
    • X. J. Wang, T. E. Milner, and J. S. Nelson, "Characterization of fluidflow velocity by optical Doppler tomography," Opt. Lett. 20(11), 1337-1339 (1995).
    • (1995) Opt. Lett. , vol.20 , Issue.11 , pp. 1337-1339
    • Wang, X.J.1    Milner, T.E.2    Nelson, J.S.3
  • 7
    • 0001226983 scopus 로고    scopus 로고
    • Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
    • Z. Chen et al., "Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media," Opt. Lett. 22(1), 64-66 (1997). (Pubitemid 127593231)
    • (1997) Optics Letters , vol.22 , Issue.1 , pp. 64-66
    • Chen, Z.1    Milner, T.E.2    Dave, D.3    Nelson, J.S.4
  • 8
    • 0000063298 scopus 로고    scopus 로고
    • In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography
    • J. A. Izatt et al., "In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomograghy," Opt. Lett. 22(18), 1439-1441 (1997). (Pubitemid 127565229)
    • (1997) Optics Letters , vol.22 , Issue.18 , pp. 1439-1441
    • Izatt, J.A.1    Kulkarni, M.D.2    Yazdanfar, S.3    Barton, J.K.4    Welch, A.J.5
  • 9
    • 0033355305 scopus 로고    scopus 로고
    • Optical Doppler tomography IEEE
    • Z. Chen et al., "Optical Doppler tomography," IEEE J. Sel. Top. Quant. Electron. 5(4), 1134-1142 (1999).
    • (1999) J. Sel. Top. Quant. Electron. , vol.5 , Issue.4 , pp. 1134-1142
    • Chen, Z.1
  • 10
    • 0000204268 scopus 로고    scopus 로고
    • Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
    • Y. H. Zhao et al., "Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity," Opt. Lett. 25(2), 114-116 (2000).
    • (2000) Opt. Lett. , vol.25 , Issue.2 , pp. 114-116
    • Zhao, Y.H.1
  • 11
    • 2942703836 scopus 로고    scopus 로고
    • Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography
    • R. A. Leitgeb et al., "Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography," Opt. Express 11(23), 3116-3121 (2003).
    • (2003) Opt. Express , vol.11 , Issue.23 , pp. 3116-3121
    • Leitgeb, R.A.1
  • 12
    • 2942733251 scopus 로고    scopus 로고
    • In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical Doppler tomography
    • B. R. White et al., "In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical Doppler tomography," Opt. Express 11(25), 3490-3497 (2003).
    • (2003) Opt. Express , vol.11 , Issue.25 , pp. 3490-3497
    • White, B.R.1
  • 15
    • 67649277409 scopus 로고    scopus 로고
    • Three-dimensional quantitative imaging of retinal and choroidal blood flow velocity using joint spectral and time domain optical coherence tomography
    • A. Szkulmowska et al., "Three-dimensional quantitative imaging of retinal and choroidal blood flow velocity using joint spectral and time domain optical coherence tomography," Opt. Express 17(13), 10584-10598 (2009).
    • (2009) Opt. Express , vol.17 , Issue.13 , pp. 10584-10598
    • Szkulmowska, A.1
  • 16
    • 43049093773 scopus 로고    scopus 로고
    • Flow velocity estimation using joint Spectral and Time domain Optical Coherence Tomography
    • DOI 10.1364/OE.16.006008
    • M. Szkulmowski et al., "Flow velocity estimation using joint spectral and time domain optical coherence tomography," Opt. Express 16(9), 6008-6025 (2008). (Pubitemid 351623313)
    • (2008) Optics Express , vol.16 , Issue.9 , pp. 6008-6025
    • Szkulmowski, M.1    Szkulmowska, A.2    Bajraszewski, T.3    Kowalczyk, A.4    Wojtkowski, M.5
  • 18
    • 77956623680 scopus 로고    scopus 로고
    • High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography
    • L. An et al., "High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography," J. Biomed. Opt. 15(2), 026011 (2010).
    • (2010) J. Biomed. Opt. , vol.15 , Issue.2 , pp. 026011
    • An, L.1
  • 19
    • 49149121261 scopus 로고    scopus 로고
    • Single-pass volumetric bidirectional blood flow imaging spectral domain optical coherence tomography using a modified Hilbert transform
    • Y. K. Tao, A. M. Davis, and J. A. Izatt, "Single-pass volumetric bidirectional blood flow imaging spectral domain optical coherence tomography using a modified Hilbert transform," Opt. Express 16(16), 12350-12361 (2008).
    • (2008) Opt. Express , vol.16 , Issue.16 , pp. 12350-12361
    • Tao, Y.K.1    Davis, A.M.2    Izatt, J.A.3
  • 20
    • 22744437125 scopus 로고    scopus 로고
    • Flow measurement without phase information in optical coherence tomography images
    • DOI 10.1364/OPEX.13.005234
    • J. Barton and S. Stromski, "Flow measurement without phase information in optical coherence tomography images," Opt. Express 13(14), 5234-5239 (2005). (Pubitemid 41029275)
    • (2005) Optics Express , vol.13 , Issue.14 , pp. 5234-5239
    • Barton, J.K.1    Stromski, S.2
  • 21
    • 78649279905 scopus 로고    scopus 로고
    • Autocorrelation optical coherence tomography for mapping transverse particle-flow velocity
    • Y. Wang and R. Wang, "Autocorrelation optical coherence tomography for mapping transverse particle-flow velocity," Opt. Lett. 35(21), 3538-3540 (2010).
    • (2010) Opt. Lett. , vol.35 , Issue.21 , pp. 3538-3540
    • Wang, Y.1    Wang, R.2
  • 22
    • 0019082097 scopus 로고
    • Proposal of a simple method of fluorescence correlation spectroscopy for measuring the direction and magnitude of a flow of fluorophores
    • H. Asai, "Proposal of a simple method of fluorescence correlation spectroscopy for measuring the direction and magnitude of a flow of fluorophores," Jpn. J. Appl. Phys. 19(11), 2279-2282 (1980). (Pubitemid 11469196)
    • (1980) Japanese journal of applied physics , vol.19 , Issue.11 , pp. 2279-2282
    • Asai Hiroshi1
  • 23
    • 84866671750 scopus 로고    scopus 로고
    • Dynamic light scattering optical coherence tomography
    • J. Lee et al., "Dynamic light scattering optical coherence tomography," Opt. Express 20(20), 22262-22277 (2012).
    • (2012) Opt. Express , vol.20 , Issue.20 , pp. 22262-22277
    • Lee, J.1
  • 24
    • 61549124515 scopus 로고    scopus 로고
    • Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography
    • Y. Wang et al., "Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography," J. Biomed. Opt. 13(6), 064003 (2008).
    • (2008) J. Biomed. Opt. , vol.13 , Issue.6 , pp. 064003
    • Wang, Y.1
  • 25
    • 79953128963 scopus 로고    scopus 로고
    • Stable absolute flow estimation with Doppler OCT based on virtual circumpapillary scans
    • A. S. G. Singh et al., "Stable absolute flow estimation with Doppler OCT based on virtual circumpapillary scans," Biomed. Opt. Express 1(4), 1047-1059 (2010).
    • (2010) Biomed. Opt. Express , vol.1 , Issue.4 , pp. 1047-1059
    • Singh, A.S.G.1
  • 26
    • 78751529751 scopus 로고    scopus 로고
    • Visualization of microvasculature by dual-beam phaseresolved Doppler optical coherence tomography
    • S. Zotter et al., "Visualization of microvasculature by dual-beam phaseresolved Doppler optical coherence tomography," Opt. Express 19(2), 1217-1227 (2011).
    • (2011) Opt. Express , vol.19 , Issue.2 , pp. 1217-1227
    • Zotter, S.1
  • 27
    • 78751519380 scopus 로고    scopus 로고
    • Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography
    • S. Makita et al., "Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography," Opt. Express 19(2), 1271-1283 (2011).
    • (2011) Opt. Express , vol.19 , Issue.2 , pp. 1271-1283
    • Makita, S.1
  • 28
    • 79961161181 scopus 로고    scopus 로고
    • Enhanced imaging of choroidal vasculature by highpenetration and dual-velocity optical coherence angiography
    • F. Jaillon et al., "Enhanced imaging of choroidal vasculature by highpenetration and dual-velocity optical coherence angiography," Biomed. Opt. Express 2(5), 1147-1158 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , Issue.5 , pp. 1147-1158
    • Jaillon, F.1
  • 29
    • 84883417517 scopus 로고    scopus 로고
    • Feasibility of capillary velocity assessment by statistical means using dual-beam spectral-domain optical coherence tomography: A preliminary study
    • S. M. Daly, C. Silien, and M. J. Leahy, "Feasibility of capillary velocity assessment by statistical means using dual-beam spectral-domain optical coherence tomography: a preliminary study," J. Biophoton. 6(9), 718-732 (2013).
    • (2013) J. Biophoton. , vol.6 , Issue.9 , pp. 718-732
    • Daly, S.M.1    Silien, C.2    Leahy, M.J.3
  • 30
    • 0000990721 scopus 로고    scopus 로고
    • Doppler-angle measurement in highly scattering media
    • D. P. Dave and T. E. Milner, "Doppler-angle measurement in highly scattering media," Opt. Lett. 25(20), 1523-1525 (2000).
    • (2000) Opt. Lett. , vol.25 , Issue.20 , pp. 1523-1525
    • Dave, D.P.1    Milner, T.E.2
  • 31
    • 33646268412 scopus 로고    scopus 로고
    • Quantitative measurements of flow velocity and direction using transversal Doppler optical coherence tomography
    • A. Royset et al., "Quantitative measurements of flow velocity and direction using transversal Doppler optical coherence tomography," Proc. SPIE 6079, 607925 (2006).
    • (2006) Proc. SPIE , vol.6079 , pp. 607925
    • Royset, A.1
  • 32
    • 33847630905 scopus 로고    scopus 로고
    • Measurement of absolute flow velocity vector using dual-angle, delay-encoded Doppler optical coherence tomography
    • DOI 10.1364/OL.32.000506
    • C. J. Pedersen et al., "Measurement of absolute flow velocity vector using dual-angle, delay-encoded Doppler optical coherence tomography," Opt. Lett. 32(5), 506-508 (2007). (Pubitemid 46363509)
    • (2007) Optics Letters , vol.32 , Issue.5 , pp. 506-508
    • Pedersen, C.J.1    Huang, D.2    Shure, M.A.3    Rollins, A.M.4
  • 33
    • 34548392368 scopus 로고    scopus 로고
    • Quantification of a three-dimensional velocity vector using spectral-domain Doppler optical coherence tomography
    • DOI 10.1364/OL.32.001587
    • Y. C. Ahn, W. Jung, and Z. Chen, "Quantification of a three-dimensional velocity vector using spectral-domain Doppler optical coherence tomography," Opt. Lett. 32(11), 1587-1589 (2007). (Pubitemid 351292807)
    • (2007) Optics Letters , vol.32 , Issue.11 , pp. 1587-1589
    • Ahn, Y.-C.1    Jung, W.2    Chen, Z.3
  • 34
    • 58149105909 scopus 로고    scopus 로고
    • Bidirectional Doppler Fourier-domain optical coherence tomography for measurement of absolute flow velocities in human retinal vessels
    • R. M.Werkmeister et al., "Bidirectional Doppler Fourier-domain optical coherence tomography for measurement of absolute flow velocities in human retinal vessels," Opt. Lett. 33(24), 2967-2969 (2008).
    • (2008) Opt. Lett. , vol.33 , Issue.24 , pp. 2967-2969
    • Werkmeister, R.M.1
  • 35
    • 84868635634 scopus 로고    scopus 로고
    • Measurement of absolute blood flow velocity and blood flow in the human retina by dual-beam bidirectional Doppler Fourier-domain optical coherence tomography
    • R. M.Werkmeister et al., "Measurement of absolute blood flow velocity and blood flow in the human retina by dual-beam bidirectional Doppler Fourier-domain optical coherence tomography," Invest. Ophthalmol. Visual Sci. 53(10), 6062-6071 (2012).
    • (2012) Invest. Ophthalmol. Visual Sci. , vol.53 , Issue.10 , pp. 6062-6071
    • Werkmeister, R.M.1
  • 36
    • 84887123679 scopus 로고    scopus 로고
    • Dove prism based rotating dual beam bidirectional Doppler OCT
    • C. Blatter et al., "Dove prism based rotating dual beam bidirectional Doppler OCT," Biomed. Opt. Express 4(7), 1188-1203 (2013).
    • (2013) Biomed. Opt. Express , vol.4 , Issue.7 , pp. 1188-1203
    • Blatter, C.1
  • 37
    • 0001015819 scopus 로고
    • Interference fringes produced by superposition of two independent maser light beams
    • G. Magyar and L. Mandel, "Interference fringes produced by superposition of two independent maser light beams," Nature 198(487), 255-256 (1963).
    • (1963) Nature , vol.198 , Issue.487 , pp. 255-256
    • Magyar, G.1    Mandel, L.2
  • 38
    • 0001936881 scopus 로고
    • Measurement of intraocular distances by backscattering spectral interferometry
    • A. F. Fercher et al., "Measurement of intraocular distances by backscattering spectral interferometry," Opt. Commun. 117(1-2), 43-48 (1995).
    • (1995) Opt. Commun. , vol.117 , Issue.1-2 , pp. 43-48
    • Fercher, A.F.1
  • 39
    • 0031695986 scopus 로고    scopus 로고
    • Coherence radar and spectral radar - New tools for dermatological diagnosis
    • G. Haeusler and M. W. Lindner, "Coherence Radar" and "Spectral Radar"-new tools for dermatological diagnosis," J. Biomed. Opt. 3(1), 21-31 (1998). (Pubitemid 128634973)
    • (1998) Journal of Biomedical Optics , vol.3 , Issue.1 , pp. 21-31
    • Hausler, G.1    Lindner, M.W.2
  • 40
    • 0036629502 scopus 로고    scopus 로고
    • In vivo human retinal imaging by Fourier domain optical coherence tomography
    • M.Wojtkowski et al., "In vivo human retinal imaging by Fourier domain optical coherence tomography," J. Biomed. Opt. 7(3), 457-463 (2002).
    • (2002) J. Biomed. Opt. , vol.7 , Issue.3 , pp. 457-463
    • Wojtkowski, M.1
  • 41
    • 0001673882 scopus 로고    scopus 로고
    • En-face coherence imaging using galvanometer scanner modulation
    • A. G. Podoleanu, G. M. Dobre, and D. A. Jackson, "En-face coherence imaging using galvanometer scanner modulation," Opt. Lett. 23(3), 147-149 (1998). (Pubitemid 128565930)
    • (1998) Optics Letters , vol.23 , Issue.3 , pp. 147-149
    • Podoleanu, A.Gh.1    Dobre, G.M.2    Jackson, D.A.3
  • 42
    • 33846893237 scopus 로고    scopus 로고
    • Single camera based spectral domain polarization sensitive optical coherence tomography
    • DOI 10.1364/OE.15.001054
    • B. Baumann et al., "Single camera based spectral domain polarization sensitive optical coherence tomography," Opt. Express 15(3), 1054-1063 (2007). (Pubitemid 46220488)
    • (2007) Optics Express , vol.15 , Issue.3 , pp. 1054-1063
    • Baumann, B.1    Gotzinger, E.2    Pircher, M.3    Hitzenberger, C.K.4
  • 43
    • 84869118483 scopus 로고    scopus 로고
    • Large-field high-speed polarization sensitive spectral domain OCT and its applications in ophthalmology
    • S. Zotter et al., "Large-field high-speed polarization sensitive spectral domain OCT and its applications in ophthalmology," Biomed. Opt. Express 3(11), 2720-2732 (2012).
    • (2012) Biomed. Opt. Express , vol.3 , Issue.11 , pp. 2720-2732
    • Zotter, S.1
  • 44
    • 84876519201 scopus 로고    scopus 로고
    • Three-beamspectral-domain optical coherence tomography for retinal imaging
    • N. Suehira et al., "Three-beamspectral-domain optical coherence tomography for retinal imaging," J. Biomed. Opt. 17(10), 106001 (2012).
    • (2012) J. Biomed. Opt. , vol.17 , Issue.10 , pp. 106001
    • Suehira, N.1
  • 45
    • 0003492957 scopus 로고    scopus 로고
    • in ANSI Z 136.1, A. N. S. Institute, Ed., Laser Institute of America, Orlando
    • American National Standards for safe use of lasers," in ANSI Z 136.1, A. N. S. Institute, Ed., Laser Institute of America, Orlando (2000).
    • (2000) American National Standards for Safe Use of Lasers
  • 46
    • 29944439716 scopus 로고    scopus 로고
    • Safety of laser products-part 1: equipment classification and requirements," in IEC 60825-1 Ed. 2, I. E. Commission, Ed. Geneva
    • Safety of laser products-part 1: equipment classification and requirements," in IEC 60825-1 Ed. 2, I. E. Commission, Ed., International Electrotechnical Commission, Geneva (2001).
    • (2001) International Electrotechnical Commission
  • 47
    • 47549090614 scopus 로고    scopus 로고
    • Phase-resolved Doppler optical coherence tomography limitations and improvements
    • A. Szkulmowska et al., "Phase-resolved Doppler optical coherence tomography limitations and improvements," Opt. Lett. 33(13), 1425-1427 (2008).
    • (2008) Opt. Lett. , vol.33 , Issue.13 , pp. 1425-1427
    • Szkulmowska, A.1
  • 48
    • 0026101781 scopus 로고
    • Optical measurement of the axial eye length by laser Doppler interferometry
    • C. K. Hitzenberger, "Optical measurement of the axial eye length by laser Doppler interferometry," Invest. Ophthalmol. Visual Sci. 32(3), 616-624 (1991).
    • (1991) Invest. Ophthalmol. Visual Sci. , vol.32 , Issue.3 , pp. 616-624
    • Hitzenberger, C.K.1
  • 50
    • 80053985896 scopus 로고    scopus 로고
    • Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT
    • B. Baumann et al., "Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT," Biomed. Opt. Express 2(6), 1539-1552 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , Issue.6 , pp. 1539-1552
    • Baumann, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.