메뉴 건너뛰기




Volumn 21, Issue 1, 2014, Pages 194-198

Range of motion and function are not affected by increased post constraint in patients undergoing posterior stabilized total knee arthroplasty

Author keywords

Constrained condylar knee; Function; Pain relief; Range of motion; Total knee arthroplasty

Indexed keywords

AGED; ANALGESIA; ARTICLE; BODY MASS; DISEASE SEVERITY; FEMALE; HUMAN; KNEE FUNCTION; KNEE OSTEOARTHRITIS; KNEE PROSTHESIS; KNEE SOCIETY SCORE; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RANGE OF MOTION; TOTAL KNEE REPLACEMENT; TREATMENT OUTCOME;

EID: 84892478481     PISSN: 09680160     EISSN: 18735800     Source Type: Journal    
DOI: 10.1016/j.knee.2013.07.002     Document Type: Article
Times cited : (34)

References (19)
  • 1
    • 0033743962 scopus 로고    scopus 로고
    • Primary constrained condylar knee arthroplasty for the arthritic valgus knee
    • Easley M.E., Insall J.N., Scuderi G.R., Bullek D.D. Primary constrained condylar knee arthroplasty for the arthritic valgus knee. Clin Orthop Relat Res 2000, 380:58-64.
    • (2000) Clin Orthop Relat Res , vol.380 , pp. 58-64
    • Easley, M.E.1    Insall, J.N.2    Scuderi, G.R.3    Bullek, D.D.4
  • 2
    • 33747881949 scopus 로고    scopus 로고
    • Ten-year survival and clinical results of constrained components in primary total knee arthroplasty
    • Lachiewicz P.F., Soileau E.S. Ten-year survival and clinical results of constrained components in primary total knee arthroplasty. J Arthroplasty 2006, 21(6):803-808.
    • (2006) J Arthroplasty , vol.21 , Issue.6 , pp. 803-808
    • Lachiewicz, P.F.1    Soileau, E.S.2
  • 3
    • 80755171221 scopus 로고    scopus 로고
    • Results of a second-generation constrained condylar prosthesis in primary total knee arthroplasty
    • Lachiewicz P.F., Soileau E.S. Results of a second-generation constrained condylar prosthesis in primary total knee arthroplasty. J Arthroplasty 2011, 26(8):1228-1231.
    • (2011) J Arthroplasty , vol.26 , Issue.8 , pp. 1228-1231
    • Lachiewicz, P.F.1    Soileau, E.S.2
  • 5
    • 0031841475 scopus 로고    scopus 로고
    • Complex primary and revision total knee arthroplasty using the condylar constrained prosthesis: an average 5-year follow-up
    • Hartford J.M., Goodman S.B., Schurman D.J., Knoblick G. Complex primary and revision total knee arthroplasty using the condylar constrained prosthesis: an average 5-year follow-up. J Arthroplasty 1998, 13(4):380-387.
    • (1998) J Arthroplasty , vol.13 , Issue.4 , pp. 380-387
    • Hartford, J.M.1    Goodman, S.B.2    Schurman, D.J.3    Knoblick, G.4
  • 6
    • 33644833559 scopus 로고    scopus 로고
    • Constraint in primary total knee arthroplasty
    • Morgan H., Battista V., Leopold S.S. Constraint in primary total knee arthroplasty. J Am Acad Orthop Surg 2005, 13(8):515-524.
    • (2005) J Am Acad Orthop Surg , vol.13 , Issue.8 , pp. 515-524
    • Morgan, H.1    Battista, V.2    Leopold, S.S.3
  • 7
    • 0026336234 scopus 로고
    • The role of fixation and bone quality on the mechanical stability of tibial knee components
    • Lee R.W., Volz R.G., Sheridan D.C. The role of fixation and bone quality on the mechanical stability of tibial knee components. Clin Orthop Relat Res 1991, 273:177-183.
    • (1991) Clin Orthop Relat Res , vol.273 , pp. 177-183
    • Lee, R.W.1    Volz, R.G.2    Sheridan, D.C.3
  • 8
    • 0021153444 scopus 로고
    • Tibial component fixation in deficient tibial bone stock
    • Brooks P.J., Walker P.S., Scott R.D. Tibial component fixation in deficient tibial bone stock. Clin Orthop Relat Res 1984, 184:302-308.
    • (1984) Clin Orthop Relat Res , vol.184 , pp. 302-308
    • Brooks, P.J.1    Walker, P.S.2    Scott, R.D.3
  • 9
    • 0031454020 scopus 로고    scopus 로고
    • The effect of tibial stem design on component micromotion in knee arthroplasty
    • Stern S.H., Wills R.D., Gilbert J.L. The effect of tibial stem design on component micromotion in knee arthroplasty. Clin Orthop Relat Res 1997, 345:44-52.
    • (1997) Clin Orthop Relat Res , vol.345 , pp. 44-52
    • Stern, S.H.1    Wills, R.D.2    Gilbert, J.L.3
  • 10
    • 85027942915 scopus 로고    scopus 로고
    • Rotational alignment in total knee arthroplasty: intraoperative inter- and intraobserver reliability of Whiteside's line
    • Vanin N., Panzica M., Dikos G., Krettek C., Hankemeier S. Rotational alignment in total knee arthroplasty: intraoperative inter- and intraobserver reliability of Whiteside's line. Arch Orthop Trauma Surg 2011, 131(11):1477-1480.
    • (2011) Arch Orthop Trauma Surg , vol.131 , Issue.11 , pp. 1477-1480
    • Vanin, N.1    Panzica, M.2    Dikos, G.3    Krettek, C.4    Hankemeier, S.5
  • 11
    • 84867855175 scopus 로고    scopus 로고
    • Aspirin for elective hip and knee arthroplasty: a multimodal thromboprophylaxis protocol
    • Vulcano E., Gesell M., Esposito A., Ma Y., Memtsoudis S.G., Gonzalez Della Valle A. Aspirin for elective hip and knee arthroplasty: a multimodal thromboprophylaxis protocol. Int Orthop 2012, 36(10):1995-2002.
    • (2012) Int Orthop , vol.36 , Issue.10 , pp. 1995-2002
    • Vulcano, E.1    Gesell, M.2    Esposito, A.3    Ma, Y.4    Memtsoudis, S.G.5    Gonzalez Della Valle, A.6
  • 13
    • 80755172134 scopus 로고    scopus 로고
    • Effect of body mass index on range of motion and manipulation after total knee arthroplasty
    • Gadinsky N.E., Ehrhardt J.K., Urband C., Westrich G.H. Effect of body mass index on range of motion and manipulation after total knee arthroplasty. J Arthroplasty 2011, 26(8):1194-1197.
    • (2011) J Arthroplasty , vol.26 , Issue.8 , pp. 1194-1197
    • Gadinsky, N.E.1    Ehrhardt, J.K.2    Urband, C.3    Westrich, G.H.4
  • 14
    • 16644394566 scopus 로고    scopus 로고
    • Factors affecting postoperative range of motion after total knee arthroplasty
    • Gatha N.M., Clarke H.D., Fuchs R., Scuderi G.R., Insall J.N. Factors affecting postoperative range of motion after total knee arthroplasty. J Knee Surg 2004, 17(4):196-202.
    • (2004) J Knee Surg , vol.17 , Issue.4 , pp. 196-202
    • Gatha, N.M.1    Clarke, H.D.2    Fuchs, R.3    Scuderi, G.R.4    Insall, J.N.5
  • 15
    • 33744984996 scopus 로고    scopus 로고
    • The role of constraint in total knee arthoplasty
    • Sculco T.P. The role of constraint in total knee arthoplasty. J Arthroplasty 2006, 21(4 Suppl. 1):54-56.
    • (2006) J Arthroplasty , vol.21 , Issue.4 SUPPL. 1 , pp. 54-56
    • Sculco, T.P.1
  • 18
    • 0030459128 scopus 로고    scopus 로고
    • Clinical and radiographic results of the Total Condylar III and Constrained Condylar total knee arthroplasty
    • Lachiewicz P.F., Falatyn S.P. Clinical and radiographic results of the Total Condylar III and Constrained Condylar total knee arthroplasty. J Arthroplasty 1996, 11(8):916-922.
    • (1996) J Arthroplasty , vol.11 , Issue.8 , pp. 916-922
    • Lachiewicz, P.F.1    Falatyn, S.P.2
  • 19
    • 0026348167 scopus 로고
    • Total knee arthroplasty using the total condylar III knee prosthesis
    • Chotivichit A.L., Cracchiolo A., Chow G.H., Dorey F. Total knee arthroplasty using the total condylar III knee prosthesis. J Arthroplasty 1991, 6(4):341-350.
    • (1991) J Arthroplasty , vol.6 , Issue.4 , pp. 341-350
    • Chotivichit, A.L.1    Cracchiolo, A.2    Chow, G.H.3    Dorey, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.