메뉴 건너뛰기




Volumn 71, Issue 2, 2014, Pages 880-884

Design, manufacture, and analysis of customized phantoms for enhanced quality control in small animal MRI systems

Author keywords

MRI; phantom; quality control

Indexed keywords

3D PRINTERS; ANIMALS; COMPUTER AIDED DESIGN; IMAGE ACQUISITION; MAGNETIC RESONANCE IMAGING; PHANTOMS; PRINTING PRESSES; QUALITY ASSURANCE; SOFTWARE DESIGN; SYSTEM STABILITY;

EID: 84892444092     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24678     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 66449112755 scopus 로고    scopus 로고
    • Measurement of MRI scanner performance with the ADNI phantom
    • Gunter JL, Bernstein MA, Borowski BJ, et al. Measurement of MRI scanner performance with the ADNI phantom. Med Phys 2009; 36: 2193-2205.
    • (2009) Med Phys , vol.36 , pp. 2193-2205
    • Gunter, J.L.1    Bernstein, M.A.2    Borowski, B.J.3
  • 2
    • 67651054994 scopus 로고    scopus 로고
    • Comparison of phantom and registration scaling corrections using the ADNI cohort
    • Clarkson MJ, Ourselin S, Nielsen C, et al. Comparison of phantom and registration scaling corrections using the ADNI cohort. Neuroimage 2009; 47: 1506-1513.
    • (2009) Neuroimage , vol.47 , pp. 1506-1513
    • Clarkson, M.J.1    Ourselin, S.2    Nielsen, C.3
  • 3
    • 33646173272 scopus 로고    scopus 로고
    • In vivo MRI and histological evaluation of brain atrophy in APP/PS1 transgenic mice
    • Delatour B, Guegan M, Volk A, et al. In vivo MRI and histological evaluation of brain atrophy in APP/PS1 transgenic mice. Neurobiol Aging 2006; 27: 835-847.
    • (2006) Neurobiol Aging , vol.27 , pp. 835-847
    • Delatour, B.1    Guegan, M.2    Volk, A.3
  • 4
    • 45849094758 scopus 로고    scopus 로고
    • Longitudinal neuroanatomical changes determined by deformation-based morphometry in a mouse model of Alzheimer's disease
    • Lau JC, Lerch JP, Sled JG, et al. Longitudinal neuroanatomical changes determined by deformation-based morphometry in a mouse model of Alzheimer's disease. Neuroimage 2008; 42: 19-27.
    • (2008) Neuroimage , vol.42 , pp. 19-27
    • Lau, J.C.1    Lerch, J.P.2    Sled, J.G.3
  • 5
    • 36048971978 scopus 로고    scopus 로고
    • Automated deformation analysis in the YAC128 Huntington disease mouse model
    • Lerch JP, Carroll JB, Spring S, et al. Automated deformation analysis in the YAC128 Huntington disease mouse model. Neuroimage 2008; 39: 32-39.
    • (2008) Neuroimage , vol.39 , pp. 32-39
    • Lerch, J.P.1    Carroll, J.B.2    Spring, S.3
  • 6
    • 33745139481 scopus 로고    scopus 로고
    • Longitudinal brain magnetic resonance imaging study of the alcohol-preferring rat. Part I: Adult brain growth
    • Sullivan EV, Adalsteinsson E, Sood R, et al. Longitudinal brain magnetic resonance imaging study of the alcohol-preferring rat. Part I: adult brain growth. Alcohol Clin Exp Res 2006; 30: 1234-1247.
    • (2006) Alcohol Clin Exp Res , vol.30 , pp. 1234-1247
    • Sullivan, E.V.1    Adalsteinsson, E.2    Sood, R.3
  • 7
    • 75249106883 scopus 로고    scopus 로고
    • Automated detection of brain atrophy patterns based on MRI for the prediction of Alzheimer's disease
    • Plant C, Teipel SJ, Oswald A, et al. Automated detection of brain atrophy patterns based on MRI for the prediction of Alzheimer's disease. Neuroimage 2010; 50: 162-174.
    • (2010) Neuroimage , vol.50 , pp. 162-174
    • Plant, C.1    Teipel, S.J.2    Oswald, A.3
  • 8
    • 79955466394 scopus 로고    scopus 로고
    • Structural MRI detects progressive regional brain atrophy and neuroprotective effects in N171-82Q Huntington's disease mouse model
    • Cheng Y, Peng Q, Hou Z, et al. Structural MRI detects progressive regional brain atrophy and neuroprotective effects in N171-82Q Huntington's disease mouse model. Neuroimage 2011; 56: 1027-1034.
    • (2011) Neuroimage , vol.56 , pp. 1027-1034
    • Cheng, Y.1    Peng, Q.2    Hou, Z.3
  • 10
    • 77349112444 scopus 로고    scopus 로고
    • A volume resolution phantom for MRI
    • Moon SY, Hornak JP,. A volume resolution phantom for MRI. Magn Reson Imaging 2010; 28: 286-289.
    • (2010) Magn Reson Imaging , vol.28 , pp. 286-289
    • Moon, S.Y.1    Hornak, J.P.2
  • 11
    • 77957330186 scopus 로고    scopus 로고
    • Highly accurate inverse consistent registration: A robust approach
    • Reuter M, Rosas HD, Fischl B,. Highly accurate inverse consistent registration: a robust approach. Neuroimage 2010; 53: 1181-1196. Bioengineering
    • (2010) Neuroimage , vol.53 , pp. 1181-1196
    • Reuter, M.1    Rosas, H.D.2    Fischl, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.