메뉴 건너뛰기




Volumn 23, Issue 2, 2014, Pages 151-158

Evaluation of the role of glenosphere design and humeral component retroversion in avoiding scapular notching during reverse shoulder arthroplasty

Author keywords

Glenoid modularity; Humeral version; Reverse shoulder arthroplasty; Scapular notching

Indexed keywords

ABDUCTION; ADDUCTION; ADULT; AGED; ARTICLE; BONE RETROVERSION; CADAVER; CENTER OF ROTATION; CONTROLLED STUDY; EXPERIMENTAL DESIGN; FEMALE; GLENOID CAVITY; GLENOSPHERE; HUMAN; HUMAN TISSUE; HUMERAL COMPONENT RETROVERSION; HUMERUS HEAD; MALE; MIDDLE AGED; PRIORITY JOURNAL; RANGE OF MOTION; REVERSE SHOULDER ARTHROPLASTY; REVERSE SHOULDER PROSTHESIS; ROTATION; SCAPULAR NOTCHING; SHOULDER IMPINGEMENT SYNDROME; VERY ELDERLY;

EID: 84892369811     PISSN: 10582746     EISSN: 15326500     Source Type: Journal    
DOI: 10.1016/j.jse.2013.05.009     Document Type: Article
Times cited : (120)

References (31)
  • 1
    • 84878132561 scopus 로고    scopus 로고
    • Bony increased-offset reversed shoulder arthroplasty (BIO-RSA): the benefits of bony lateralization
    • Sauramps Médical, Montpellier, France, G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.)
    • Boileau P., Moineau G., Roussanne Y., O'Shea K. Bony increased-offset reversed shoulder arthroplasty (BIO-RSA): the benefits of bony lateralization. Shoulder concepts 2010: the glenoid 2010, 371-387. Sauramps Médical, Montpellier, France. G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.).
    • (2010) Shoulder concepts 2010: the glenoid , pp. 371-387
    • Boileau, P.1    Moineau, G.2    Roussanne, Y.3    O'Shea, K.4
  • 2
    • 13844322381 scopus 로고    scopus 로고
    • Grammont reverse prosthesis: design, rationale, and biomechanics
    • Boileau P., Watkinson D.J., Hatzidakis A.M., Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg 2005, 14(Suppl S):147S-161S. 10.1016/j.jse.2004.10.006.
    • (2005) J Shoulder Elbow Surg , vol.14 , Issue.SUPPL S
    • Boileau, P.1    Watkinson, D.J.2    Hatzidakis, A.M.3    Balg, F.4
  • 3
    • 0036185019 scopus 로고    scopus 로고
    • Early results of a reverse design prosthesis in the treatment of arthritis of the shoulder in elderly patients with a large rotator cuff tear
    • Boulahia A., Edwards T.B., Walch G., Baratta R.V. Early results of a reverse design prosthesis in the treatment of arthritis of the shoulder in elderly patients with a large rotator cuff tear. Orthopedics 2002, 25:129-133.
    • (2002) Orthopedics , vol.25 , pp. 129-133
    • Boulahia, A.1    Edwards, T.B.2    Walch, G.3    Baratta, R.V.4
  • 4
    • 64849102177 scopus 로고    scopus 로고
    • Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: range of motion and risk of scapular notching
    • Chou J., Malak S.F., Anderson I.A., Astley T., Poon P.C. Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: range of motion and risk of scapular notching. J Shoulder Elbow Surg 2009, 18:354-359. 10.1016/j.jse.2009.01.015.
    • (2009) J Shoulder Elbow Surg , vol.18 , pp. 354-359
    • Chou, J.1    Malak, S.F.2    Anderson, I.A.3    Astley, T.4    Poon, P.C.5
  • 5
    • 84888407667 scopus 로고    scopus 로고
    • Influence of the sphere diameter on radiographic and clinical results of RSA
    • Sauramps Médical, Montpellier, France, G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.)
    • De Wilde L. Influence of the sphere diameter on radiographic and clinical results of RSA. Shoulder concepts 2010: the glenoid 2010, 393-402. Sauramps Médical, Montpellier, France. G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.).
    • (2010) Shoulder concepts 2010: the glenoid , pp. 393-402
    • De Wilde, L.1
  • 6
    • 23044470389 scopus 로고    scopus 로고
    • The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients
    • Frankle M., Siegal S., Pupello D., Saleem A., Mighell M., Vasey M. The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients. J Bone Joint Surg Am 2005, 87:1697-1705. 10.2106/JBJS.D.02813.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1697-1705
    • Frankle, M.1    Siegal, S.2    Pupello, D.3    Saleem, A.4    Mighell, M.5    Vasey, M.6
  • 7
    • 70349755608 scopus 로고    scopus 로고
    • Glenoid morphology in reverse shoulder arthroplasty: classification and surgical implications
    • Frankle M.A., Teramoto A., Luo Z.P., Levy J.C., Pupello D. Glenoid morphology in reverse shoulder arthroplasty: classification and surgical implications. J Shoulder Elbow Surg 2009, 18:874-885. 10.1016/j.jse.2009.02.013.
    • (2009) J Shoulder Elbow Surg , vol.18 , pp. 874-885
    • Frankle, M.A.1    Teramoto, A.2    Luo, Z.P.3    Levy, J.C.4    Pupello, D.5
  • 9
    • 33746864860 scopus 로고    scopus 로고
    • Reverse total shoulder arthroplasty. Survivorship analysis of eighty replacements followed for five to ten years
    • Guery J., Favard L., Sirveaux F., Oudet D., Molé D., Walch G. Reverse total shoulder arthroplasty. Survivorship analysis of eighty replacements followed for five to ten years. J Bone Joint Surg Am 2006, 88:1742-1747. 10.2106/JBJS.E.00851.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 1742-1747
    • Guery, J.1    Favard, L.2    Sirveaux, F.3    Oudet, D.4    Molé, D.5    Walch, G.6
  • 10
    • 57349117150 scopus 로고    scopus 로고
    • Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors
    • Gutiérrez S., Comiskey C.A., Luo Z.P., Pupello D.R., Frankle M.A. Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors. J Bone Joint Surg Am 2008, 90:2606-2615. 10.2106/JBJS.H.00012.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 2606-2615
    • Gutiérrez, S.1    Comiskey, C.A.2    Luo, Z.P.3    Pupello, D.R.4    Frankle, M.A.5
  • 11
    • 46049091779 scopus 로고    scopus 로고
    • Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model
    • Gutiérrez S., Levy J.C., Frankle M.A., Cuff D., Keller T.S., Pupello D.R., et al. Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model. J Shoulder Elbow Surg 2008, 17:608-615. 10.1016/j.jse.2007.11.010.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 608-615
    • Gutiérrez, S.1    Levy, J.C.2    Frankle, M.A.3    Cuff, D.4    Keller, T.S.5    Pupello, D.R.6
  • 12
    • 34247854969 scopus 로고    scopus 로고
    • Center of rotation affects abduction range of motion of reverse shoulder arthroplasty
    • Gutiérrez S., Levy J.C., Lee W.E., Keller T.S., Maitland M.E. Center of rotation affects abduction range of motion of reverse shoulder arthroplasty. Clin Orthop Relat Res 2007, 458:78-82. 10.1097/BLO.0b013e31803d0f57.
    • (2007) Clin Orthop Relat Res , vol.458 , pp. 78-82
    • Gutiérrez, S.1    Levy, J.C.2    Lee, W.E.3    Keller, T.S.4    Maitland, M.E.5
  • 13
    • 84892370006 scopus 로고    scopus 로고
    • Reverse total shoulder arthroplasty and glenoid notching
    • Sauramps Médical, Montpellier, France, G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.)
    • Jost B., Gerber C. Reverse total shoulder arthroplasty and glenoid notching. Shoulder concepts 2010: the glenoid 2010, 323-327. Sauramps Médical, Montpellier, France. G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.).
    • (2010) Shoulder concepts 2010: the glenoid , pp. 323-327
    • Jost, B.1    Gerber, C.2
  • 14
    • 67449106130 scopus 로고    scopus 로고
    • Reverse shoulder arthroplasty: does reduced medialisation improve radiological and clinical results?
    • Kalouche I., Sevivas N., Wahegaonker A., Sauzieres P., Katz D., Valenti P. Reverse shoulder arthroplasty: does reduced medialisation improve radiological and clinical results?. Acta Orthop Belg 2009, 75:158-166.
    • (2009) Acta Orthop Belg , vol.75 , pp. 158-166
    • Kalouche, I.1    Sevivas, N.2    Wahegaonker, A.3    Sauzieres, P.4    Katz, D.5    Valenti, P.6
  • 15
    • 46049086371 scopus 로고    scopus 로고
    • Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, part one: the twelve-mm rule
    • Kelly J.D., Humphrey C.S., Norris T.R. Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, part one: the twelve-mm rule. J Shoulder Elbow Surg 2008, 17:589-594. 10.1016/j.jse.2007.08.013.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 589-594
    • Kelly, J.D.1    Humphrey, C.S.2    Norris, T.R.3
  • 16
    • 37149019008 scopus 로고    scopus 로고
    • Scapular notching in reverse shoulder arthroplasty. Reverse shoulder arthroplasty
    • Sauramps Médical, Paris, France, G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.)
    • Lévigne C., Boileau P., Favard L. Scapular notching in reverse shoulder arthroplasty. Reverse shoulder arthroplasty. Reverse shoulder arthroplasty 2006, 353-372. Sauramps Médical, Paris, France. G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.).
    • (2006) Reverse shoulder arthroplasty , pp. 353-372
    • Lévigne, C.1    Boileau, P.2    Favard, L.3
  • 18
    • 41649085888 scopus 로고    scopus 로고
    • Excentered scapulohumeral osteoarthritis [in French]
    • doi: RCO-10-2007-93-S6-0035-1040-101019-200520033
    • Molé D., Favard L. Excentered scapulohumeral osteoarthritis [in French]. Rev Chir Orthop Réparatrice Appar Mot 2007, 93(Suppl):37-94. doi: RCO-10-2007-93-S6-0035-1040-101019-200520033.
    • (2007) Rev Chir Orthop Réparatrice Appar Mot , vol.93 , Issue.SUPPL , pp. 37-94
    • Molé, D.1    Favard, L.2
  • 19
    • 25444490893 scopus 로고    scopus 로고
    • Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis
    • Nyffeler R.W., Werner C.M., Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg 2005, 14:524-528. 10.1016/j.jse.2004.09.010.
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 524-528
    • Nyffeler, R.W.1    Werner, C.M.2    Gerber, C.3
  • 20
    • 9144221439 scopus 로고    scopus 로고
    • Analysis of a retrieved Delta III total shoulder prosthesis
    • Nyffeler R.W., Werner C.M., Simmen B.R., Gerber C. Analysis of a retrieved Delta III total shoulder prosthesis. J Bone Joint Surg Br 2004, 86:1187-1191. 10.1302/0301-620X.86B8.15228.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 1187-1191
    • Nyffeler, R.W.1    Werner, C.M.2    Simmen, B.R.3    Gerber, C.4
  • 21
    • 68749108180 scopus 로고    scopus 로고
    • An evaluation of the relationships between reverse shoulder design parameters and range of motion, impingement, and stability
    • Roche C., Flurin P.H., Wright T., Crosby L.A., Mauldin M., Zuckerman J.D. An evaluation of the relationships between reverse shoulder design parameters and range of motion, impingement, and stability. J Shoulder Elbow Surg 2009, 18:734-741. 10.1016/j.jse.2008.12.008.
    • (2009) J Shoulder Elbow Surg , vol.18 , pp. 734-741
    • Roche, C.1    Flurin, P.H.2    Wright, T.3    Crosby, L.A.4    Mauldin, M.5    Zuckerman, J.D.6
  • 22
    • 33847633584 scopus 로고    scopus 로고
    • Predictors of scapular notching in patients managed with the Delta III reverse shoulder replacement
    • Simovitch R., Zumstein M., Lohri E., Helmy M., Gerber C. Predictors of scapular notching in patients managed with the Delta III reverse shoulder replacement. J Bone Joint Surg Am 2007, 89:588-600. 10.2106/JBJS.F.00226.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 588-600
    • Simovitch, R.1    Zumstein, M.2    Lohri, E.3    Helmy, M.4    Gerber, C.5
  • 23
    • 84892372910 scopus 로고    scopus 로고
    • Use of the Grammont prosthesis for treating shoulder arthritis with rotator cuff damage
    • A multicenter series of 42 cases [in French]. Dissertation, Medicine, L'Université de Nancy I;
    • Sirveaux F. Use of the Grammont prosthesis for treating shoulder arthritis with rotator cuff damage. A multicenter series of 42 cases [in French]. Dissertation, Medicine, L'Université de Nancy I;1997.
    • (1997)
    • Sirveaux, F.1
  • 24
    • 2342430784 scopus 로고    scopus 로고
    • Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders
    • Sirveaux F., Favard L., Oudet D., Huquet D., Walch G., Molé D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br 2004, 86:388-395. 10.1302/0301-620X.86B3.14024.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 388-395
    • Sirveaux, F.1    Favard, L.2    Oudet, D.3    Huquet, D.4    Walch, G.5    Molé, D.6
  • 25
    • 79955791678 scopus 로고    scopus 로고
    • Effect of humeral component version on impingement in reverse total shoulder arthroplasty
    • Stephenson D., Oh J., McGarry M., Rick Hatch G.F., Lee T. Effect of humeral component version on impingement in reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2011, 20(4):652-658. 10.1016/j.jse.2010.08.020.
    • (2011) J Shoulder Elbow Surg , vol.20 , Issue.4 , pp. 652-658
    • Stephenson, D.1    Oh, J.2    McGarry, M.3    Rick Hatch, G.F.4    Lee, T.5
  • 26
    • 84892364505 scopus 로고    scopus 로고
    • Biomechanical rationale for BIO-RSA and metallic lateralization
    • Sauramps Médical, Montpellier, France, G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.)
    • Terrier A., Farron A. Biomechanical rationale for BIO-RSA and metallic lateralization. Shoulder concepts 2010: the glenoid 2010, 365-370. Sauramps Médical, Montpellier, France. G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.).
    • (2010) Shoulder concepts 2010: the glenoid , pp. 365-370
    • Terrier, A.1    Farron, A.2
  • 27
    • 56549101458 scopus 로고    scopus 로고
    • Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis
    • Torrens C., Corrales M., Gonzalez G., Solano A., Caceres E. Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis. J Orthop Surg Res 2008, 3:49. 10.1186/1749-799X-3-49.
    • (2008) J Orthop Surg Res , vol.3 , pp. 49
    • Torrens, C.1    Corrales, M.2    Gonzalez, G.3    Solano, A.4    Caceres, E.5
  • 28
    • 0346694505 scopus 로고    scopus 로고
    • Delta 3 reversed prosthesis for osteoarthritis with massive rotator cuff tear: long term results
    • Sauramps Médical, Paris, France, G. Walch, P. Boileau, D. Molé (Eds.)
    • Valenti P.H., Boutens D., Nérot C. Delta 3 reversed prosthesis for osteoarthritis with massive rotator cuff tear: long term results. 2000 Shoulder prostheses. Two to ten years follow-up 2001, 253-259. Sauramps Médical, Paris, France. G. Walch, P. Boileau, D. Molé (Eds.).
    • (2001) 2000 Shoulder prostheses. Two to ten years follow-up , pp. 253-259
    • Valenti, P.H.1    Boutens, D.2    Nérot, C.3
  • 29
    • 84892366116 scopus 로고    scopus 로고
    • Lateralization in the design of the reverse shoulder arthroplasty. Is it dangerous? Is it useful?
    • Sauramps Médical, Montpellier, France, G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.)
    • Valenti P., Katz D., Sauzières P., Kilinc A. Lateralization in the design of the reverse shoulder arthroplasty. Is it dangerous? Is it useful?. Shoulder concepts 2010: the glenoid 2010, 353-364. Sauramps Médical, Montpellier, France. G. Walch, P. Boileau, D. Molé, L. Favard, C. Lévigne, F. Sirveaux (Eds.).
    • (2010) Shoulder concepts 2010: the glenoid , pp. 353-364
    • Valenti, P.1    Katz, D.2    Sauzières, P.3    Kilinc, A.4
  • 30
    • 42749092913 scopus 로고    scopus 로고
    • Invitro and finite element analysis of glenoid bone/baseplate interaction in the reverse shoulder design
    • Virani N.A., Harman M., Li K., Levy J., Pupello D.R., Frankle M.A. Invitro and finite element analysis of glenoid bone/baseplate interaction in the reverse shoulder design. J Shoulder Elbow Surg 2008, 17:509-521. 10.1016/j.jse.2007.11.003.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 509-521
    • Virani, N.A.1    Harman, M.2    Li, K.3    Levy, J.4    Pupello, D.R.5    Frankle, M.A.6
  • 31
    • 21444449860 scopus 로고    scopus 로고
    • Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis
    • Werner C.M., Steinmann P.A., Gilbart M., Gerber C. Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. JBone Joint Surg Am 2005, 87:1476-1486. 10.2106/JBJS.D.02342.
    • (2005) JBone Joint Surg Am , vol.87 , pp. 1476-1486
    • Werner, C.M.1    Steinmann, P.A.2    Gilbart, M.3    Gerber, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.