메뉴 건너뛰기




Volumn 24, Issue 1, 2014, Pages 71-80

Methods to reduce the CO2 concentration of educational buildings utilizing internal ventilation by transferred air

Author keywords

Indoor air quality; Internal openings; Measurements; Modeling; School buildings; Transferred air

Indexed keywords

AIR QUALITY; CARBON DIOXIDE; ENERGY UTILIZATION; INDOOR AIR POLLUTION; SCHOOL BUILDINGS;

EID: 84892367005     PISSN: 09056947     EISSN: 16000668     Source Type: Journal    
DOI: 10.1111/ina.12059     Document Type: Article
Times cited : (5)

References (24)
  • 1
    • 0003842308 scopus 로고    scopus 로고
    • ASHRAE, Atlanta, GA, American Society of Heating, Refrigerating and Air conditioning Engineers Inc.
    • ASHRAE (1997) ASHRAE Handbook - Fundamentals, Atlanta, GA, American Society of Heating, Refrigerating and Air conditioning Engineers Inc.
    • (1997) ASHRAE Handbook - Fundamentals
  • 4
    • 85153162110 scopus 로고    scopus 로고
    • CENGas welding equipment - Pressure gouges used in welding, cutting and allied processes, Brussels, European Committee for Standardization (European Standard EN 562).
    • CEN (2003) Gas welding equipment - Pressure gouges used in welding, cutting and allied processes, Brussels, European Committee for Standardization (European Standard EN 562).
    • (2003)
  • 5
    • 85153162855 scopus 로고    scopus 로고
    • CENErgonomics of the thermal environment - Determination of the metabolic rate, Brussels, European Committee for Standardization (European Standard EN 8996).
    • CEN (2004) Ergonomics of the thermal environment - Determination of the metabolic rate, Brussels, European Committee for Standardization (European Standard EN 8996).
    • (2004)
  • 6
    • 85153167967 scopus 로고    scopus 로고
    • CENIndoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics, Brussels, European Committee for Standardization (European Standard EN 15251).
    • CEN (2007) Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics, Brussels, European Committee for Standardization (European Standard EN 15251).
    • (2007)
  • 8
  • 10
    • 38949126224 scopus 로고    scopus 로고
    • Single-sided natural ventilation driven by wind pressure and temperature difference
    • Larsen, T.S. and Heiselberg, P. (2008) Single-sided natural ventilation driven by wind pressure and temperature difference, Energy Build., 40, 1031-1040.
    • (2008) Energy Build. , vol.40 , pp. 1031-1040
    • Larsen, T.S.1    Heiselberg, P.2
  • 11
    • 26444480184 scopus 로고    scopus 로고
    • 2 concentrations in small commercial buildings
    • 2 concentrations in small commercial buildings, Build. Environ., 41, 184-194.
    • (2006) Build. Environ. , vol.41 , pp. 184-194
    • Lawrence, T.M.1    Braun, J.E.2
  • 12
    • 79960728953 scopus 로고    scopus 로고
    • 2 control and energy saving in buildings
    • 2 control and energy saving in buildings, Energy Build., 43, 2499-2508.
    • (2011) Energy Build. , vol.43 , pp. 2499-2508
    • Lu, T.1    Lu, X.2    Viljanen, M.3
  • 13
    • 13544255585 scopus 로고    scopus 로고
    • Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature
    • Mendell, M.J. and Heath, G.A. (2005) Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature, Indoor Air, 15, 27-52.
    • (2005) Indoor Air , vol.15 , pp. 27-52
    • Mendell, M.J.1    Heath, G.A.2
  • 14
    • 84855243982 scopus 로고    scopus 로고
    • 2-based demand-controlled ventilation strategy for multi-zone HVAC systems
    • 2-based demand-controlled ventilation strategy for multi-zone HVAC systems, Energy Build., 45, 72-81.
    • (2012) Energy Build. , vol.45 , pp. 72-81
    • Nassif, N.1
  • 15
    • 80053324199 scopus 로고    scopus 로고
    • 2-based demand controlled ventilation under new ASHRAE standard 62.1-2010: a case study for a gymnasium of an elementary school at West Lafayette, Indiana
    • 2-based demand controlled ventilation under new ASHRAE standard 62.1-2010: a case study for a gymnasium of an elementary school at West Lafayette, Indiana, Energy Build., 43, 3216-3225.
    • (2011) Energy Build. , vol.43 , pp. 3216-3225
    • Owen Ng, M.1    Qu, M.2    Zheng, P.3    Li, Z.4    Hang, Y.5
  • 16
    • 37349028760 scopus 로고    scopus 로고
    • A review on buildings energy consumption information
    • Pérez-Lombard, L., Ortiz, J. and Pout, C. (2008) A review on buildings energy consumption information, Energy Build., 40, 394-398.
    • (2008) Energy Build. , vol.40 , pp. 394-398
    • Pérez-Lombard, L.1    Ortiz, J.2    Pout, C.3
  • 17
    • 84892368582 scopus 로고    scopus 로고
    • REHVA, Brussels, Federation of European Heating, Ventilation and Air-conditioning Associations.
    • REHVA (2010) Indoor Environment and Energy Efficiency in Schools - Part 1 Principles, Brussels, Federation of European Heating, Ventilation and Air-conditioning Associations.
    • (2010) Indoor Environment and Energy Efficiency in Schools - Part 1 Principles
  • 19
    • 85153164465 scopus 로고    scopus 로고
    • Scientific basis for design of ventilation for health, productivity and good energy efficiency. In: Proceedings of the Indoor Air Congress, Copenhagen, Denmark.
    • Seppänen, O. (2008) Scientific basis for design of ventilation for health, productivity and good energy efficiency. In: Proceedings of the Indoor Air Congress, Copenhagen, Denmark.
    • (2008)
    • Seppänen, O.1
  • 20
    • 77956231624 scopus 로고    scopus 로고
    • 2-based adaptive demand-controlled ventilation strategy in a multi-zone office building
    • 2-based adaptive demand-controlled ventilation strategy in a multi-zone office building, Build. Environ., 46, 124-133.
    • (2011) Build. Environ. , vol.46 , pp. 124-133
    • Sun, Z.1    Wang, S.2    Ma, Z.3
  • 22
    • 85153156657 scopus 로고    scopus 로고
    • Wirepas Oy[Online], (Accessed January 2013).
    • Wirepas Oy (2010) [Online] http://wirepas.com. (Accessed January 2013).
    • (2010)
  • 23
    • 84870851406 scopus 로고    scopus 로고
    • Multi-zone building energy management using intelligent control and optimization
    • Yang, R. and Wang, L. (2012) Multi-zone building energy management using intelligent control and optimization, Sustain. Citi. Soc., 6, 16-21.
    • (2012) Sustain. Citi. Soc. , vol.6 , pp. 16-21
    • Yang, R.1    Wang, L.2
  • 24
    • 78651457750 scopus 로고    scopus 로고
    • Evaluation of four control strategies for building VAV air-conditioning systems
    • Yang, X.B., Jin, X.Q., Du, Z.M., Fan, B. and Chai, X.F. (2011) Evaluation of four control strategies for building VAV air-conditioning systems, Energy Build., 43, 414-422.
    • (2011) Energy Build. , vol.43 , pp. 414-422
    • Yang, X.B.1    Jin, X.Q.2    Du, Z.M.3    Fan, B.4    Chai, X.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.