Volumn 73, Issue , 2014, Pages 151-161

The relationship between filter pressure drop, indoor air quality, and energy consumption in rooftop HVAC units

Author keywords

Clean air delivery rate; Commercial buildings; Filtration; HVAC energy use; Packaged terminal air conditioner (PTAC)

Indexed keywords

CLEAN AIR; COMMERCIAL BUILDING; ENERGY USE; HEALTHY INDOOR ENVIRONMENTS; HIGH EFFICIENCY FILTER; INCREASE IN PRESSURE; INDOOR AIR QUALITY; PACKAGED TERMINAL AIR CONDITIONER (PTAC);

EID: 84892175049     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2013.12.010     Document Type: Article
Times cited : (126)

References (36)
  • 1
    • 84892154275 scopus 로고    scopus 로고
    • EIA. Available from:.
    • EIA. 2003. Available from:. http://www.eia.gov/emeu/cbecs/cbecs2003/detailed_tables_2003/detailed_tables_2003.html.
    • (2003)
  • 4
    • 0030262669 scopus 로고    scopus 로고
    • Effect of reduced evaporator airflow on the high temperature performance of air conditioners
    • Rodriguez A.G., O'Neal D., Davis M., Kondepudi S. Effect of reduced evaporator airflow on the high temperature performance of air conditioners. Energy Build 1996, 24:195-201.
    • (1996) Energy Build , vol.24 , pp. 195-201
    • Rodriguez, A.G.1    O'Neal, D.2    Davis, M.3    Kondepudi, S.4
  • 5
    • 0031388460 scopus 로고    scopus 로고
    • Impact of evaporator coil airflow in residential air-conditioning systems
    • Parker D.S., Sherwin J.R., Raustad R.A., Shirey D.B. Impact of evaporator coil airflow in residential air-conditioning systems. ASHRAE Tran 1997, 103:395-405.
    • (1997) ASHRAE Tran , vol.103 , pp. 395-405
    • Parker, D.S.1    Sherwin, J.R.2    Raustad, R.A.3    Shirey, D.B.4
  • 6
    • 33847156360 scopus 로고    scopus 로고
    • The impact of evaporator fouling and filtration on the performance of packaged air conditioners
    • Yang L., Braun J.E., Groll E.A. The impact of evaporator fouling and filtration on the performance of packaged air conditioners. Int J Refrig 2007, 30:506-514.
    • (2007) Int J Refrig , vol.30 , pp. 506-514
    • Yang, L.1    Braun, J.E.2    Groll, E.A.3
  • 7
    • 77954265980 scopus 로고    scopus 로고
    • Energy implications of filtration in residential and light-commercial buildings
    • Stephens B., Siegel J.A., Novoselac A. Energy implications of filtration in residential and light-commercial buildings. ASHRAE Tran 2010, 116:346-357.
    • (2010) ASHRAE Tran , vol.116 , pp. 346-357
    • Stephens, B.1    Siegel, J.A.2    Novoselac, A.3
  • 8
    • 77952037163 scopus 로고    scopus 로고
    • The effects of filtration on pressure drop and energy consumption in residential HVAC systems (RP-1299)
    • Stephens B., Novoselac A., Siegel J.A. The effects of filtration on pressure drop and energy consumption in residential HVAC systems (RP-1299). HVAC&R Res 2010, 16:315-329.
    • (2010) HVAC&R Res , vol.16 , pp. 315-329
    • Stephens, B.1    Novoselac, A.2    Siegel, J.A.3
  • 9
    • 77955860781 scopus 로고    scopus 로고
    • The effect of ventilation rate and filter performance on indoor particle concentration and fan power consumption in a residential housing unit
    • Noh K.-C., Hwang J. The effect of ventilation rate and filter performance on indoor particle concentration and fan power consumption in a residential housing unit. Indoor Built Environ 2010, 19:444-452.
    • (2010) Indoor Built Environ , vol.19 , pp. 444-452
    • Noh, K.-C.1    Hwang, J.2
  • 11
    • 84865593724 scopus 로고    scopus 로고
    • The impact of air filter pressure drop on the performance of typical air-conditioning systems
    • Nassif N. The impact of air filter pressure drop on the performance of typical air-conditioning systems. Build Simul 2012, 5:345-350.
    • (2012) Build Simul , vol.5 , pp. 345-350
    • Nassif, N.1
  • 13
    • 0034581450 scopus 로고    scopus 로고
    • Using extended surface air filters in heating ventilation and air conditioning systems: reducing utility and maintenance costs while benefiting the environment
    • American Council for an Energy-Efficient Economy
    • Chimack M.J., Sellers D. Using extended surface air filters in heating ventilation and air conditioning systems: reducing utility and maintenance costs while benefiting the environment. Proceedings from the 2000 summer study on energy efficiency in buildings 2000, American Council for an Energy-Efficient Economy.
    • (2000) Proceedings from the 2000 summer study on energy efficiency in buildings
    • Chimack, M.J.1    Sellers, D.2
  • 14
    • 33644681944 scopus 로고    scopus 로고
    • Achieving "excellent" indoor air quality in commercial offices equipped with air-handling unit - respirable suspended particulate
    • Lam K.S., Chan F.S., Fung W.Y., Lui B.S.S., Lau L.W.L. Achieving "excellent" indoor air quality in commercial offices equipped with air-handling unit - respirable suspended particulate. Indoor Air 2006, 16:86-97.
    • (2006) Indoor Air , vol.16 , pp. 86-97
    • Lam, K.S.1    Chan, F.S.2    Fung, W.Y.3    Lui, B.S.S.4    Lau, L.W.L.5
  • 15
    • 0036987752 scopus 로고    scopus 로고
    • Performance and costs of particle air filtration technologies
    • Fisk W.J., Faulkner D., Palonen J., Seppanen O. Performance and costs of particle air filtration technologies. Indoor Air 2002, 12:223-234.
    • (2002) Indoor Air , vol.12 , pp. 223-234
    • Fisk, W.J.1    Faulkner, D.2    Palonen, J.3    Seppanen, O.4
  • 16
  • 17
    • 45249103518 scopus 로고    scopus 로고
    • Is the use of particle air filtration justified? Costs and benefits of filtration with regard to health effects, building cleaning and occupant productivity
    • Bekö G., Clausen G., Weschler C.J. Is the use of particle air filtration justified? Costs and benefits of filtration with regard to health effects, building cleaning and occupant productivity. Build Environ 2008, 43:1647-1657.
    • (2008) Build Environ , vol.43 , pp. 1647-1657
    • Bekö, G.1    Clausen, G.2    Weschler, C.J.3
  • 19
    • 77950789919 scopus 로고    scopus 로고
    • Delivering sustainability promise to HVAC air filtration. Part I: classification of energy efficiency for air filters
    • Sun C., Woodman D. Delivering sustainability promise to HVAC air filtration. Part I: classification of energy efficiency for air filters. ASHRAE Tran 2009, 115:581-587.
    • (2009) ASHRAE Tran , vol.115 , pp. 581-587
    • Sun, C.1    Woodman, D.2
  • 20
    • 79952677066 scopus 로고    scopus 로고
    • Delivering sustainability promise to HVAC air filtration. Part II: life cycle sustainability of air filters
    • Sun C. Delivering sustainability promise to HVAC air filtration. Part II: life cycle sustainability of air filters. ASHRAE Tran 2010, 116:25-32.
    • (2010) ASHRAE Tran , vol.116 , pp. 25-32
    • Sun, C.1
  • 21
    • 84857042276 scopus 로고    scopus 로고
    • Predicting the energy use and operation cost of HVAC air filters
    • Montgomery J.F., Green S.I., Bartlett K. Predicting the energy use and operation cost of HVAC air filters. Energy Build 2012, 47:643-650.
    • (2012) Energy Build , vol.47 , pp. 643-650
    • Montgomery, J.F.1    Green, S.I.2    Bartlett, K.3
  • 22
    • 84884250337 scopus 로고    scopus 로고
    • HVAC filtration for controlling infectious airborne disease transmission in indoor environments: predicting risk reductions and operational costs
    • Azimi P., Stephens B. HVAC filtration for controlling infectious airborne disease transmission in indoor environments: predicting risk reductions and operational costs. Build Environ 2013, 70:150-160.
    • (2013) Build Environ , vol.70 , pp. 150-160
    • Azimi, P.1    Stephens, B.2
  • 23
    • 70449530834 scopus 로고    scopus 로고
    • Can combining economizers with improved filtration save energy and protect equipment in data centers?
    • Shehabi A., Ganguly S., Gundel L.A., Horvath A., Kirchstetter T.W., Lunden M.M., et al. Can combining economizers with improved filtration save energy and protect equipment in data centers?. Build Environ 2010, 45(3):718-726.
    • (2010) Build Environ , vol.45 , Issue.3 , pp. 718-726
    • Shehabi, A.1    Ganguly, S.2    Gundel, L.A.3    Horvath, A.4    Kirchstetter, T.W.5    Lunden, M.M.6
  • 25
    • 84892185931 scopus 로고    scopus 로고
    • Personal communication with Dr. James Braun
    • Personal communication with Dr. James Braun. 2013.
    • (2013)
  • 26
    • 84892175000 scopus 로고    scopus 로고
    • Personal communication with Dr. Nabil Nassif
    • Personal communication with Dr. Nabil Nassif. 2013.
    • (2013)
  • 29
    • 84876099348 scopus 로고
    • Fractional aerosol filtration efficiency of in-duct ventilation air cleaners
    • Hanley J.T., Ensor D.S., Smith D.D., Sparks L.E. Fractional aerosol filtration efficiency of in-duct ventilation air cleaners. Indoor Air 1994, 4:169-178.
    • (1994) Indoor Air , vol.4 , pp. 169-178
    • Hanley, J.T.1    Ensor, D.S.2    Smith, D.D.3    Sparks, L.E.4
  • 30
    • 52649091063 scopus 로고    scopus 로고
    • Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems
    • MacIntosh D.L., Myatt T.A., Ludwig J.F., Baker B.J., Suh H.H., Spengler J.D. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems. JAir Waste Manag 2008, 58:1474-1482.
    • (2008) JAir Waste Manag , vol.58 , pp. 1474-1482
    • MacIntosh, D.L.1    Myatt, T.A.2    Ludwig, J.F.3    Baker, B.J.4    Suh, H.H.5    Spengler, J.D.6
  • 31
    • 0022935099 scopus 로고
    • Energy use implications of methods to maintain heat exchanger coil cleanliness
    • Krafthefter B., Bonne U. Energy use implications of methods to maintain heat exchanger coil cleanliness. ASHRAE Tran 1986, 92:420-431.
    • (1986) ASHRAE Tran , vol.92 , pp. 420-431
    • Krafthefter, B.1    Bonne, U.2
  • 32
    • 84892145690 scopus 로고    scopus 로고
    • Is there a downside to high-MERV filters?
    • Available from:
    • Springer D. Is there a downside to high-MERV filters? Available from:. http://www.homeenergy.org/show/article/id/667.
    • Springer, D.1
  • 33
    • 27644532780 scopus 로고    scopus 로고
    • Filter bypass: implications for filter efficiency
    • Ward M., Siegel J.A. Filter bypass: implications for filter efficiency. ASHRAE Tran 2005, 111:1091-1100.
    • (2005) ASHRAE Tran , vol.111 , pp. 1091-1100
    • Ward, M.1    Siegel, J.A.2
  • 34
    • 70449464566 scopus 로고    scopus 로고
    • Implications of filter bypass
    • VerShaw J. Implications of filter bypass. ASHRAE Tran 2009, 115:191-198.
    • (2009) ASHRAE Tran , vol.115 , pp. 191-198
    • VerShaw, J.1
  • 35
    • 0031847924 scopus 로고    scopus 로고
    • Aerosol loading performance of electret filter media
    • Barrett L.W., Rousseau A.D. Aerosol loading performance of electret filter media. Am Ind Hyg Assoc 1998, 59:532-539.
    • (1998) Am Ind Hyg Assoc , vol.59 , pp. 532-539
    • Barrett, L.W.1    Rousseau, A.D.2
  • 36
    • 84892140799 scopus 로고    scopus 로고
    • Effects of particle loading on electrically charged filters in an HVAC system
    • University of Minnesota, School of Public Health, Division of Environmental and Occupational health
    • Raynor PC, Chae SJ. Effects of particle loading on electrically charged filters in an HVAC system. University of Minnesota, School of Public Health, Division of Environmental and Occupational health. 200.
    • Raynor, P.C.1    Chae, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.