메뉴 건너뛰기




Volumn 30, Issue 1, 2014, Pages 135-142

Effects of changing physiologic conditions on the in vivo quantification of hemodynamic variables in cerebral aneurysms treated with flow diverting devices

Author keywords

Cerebral aneurysm; Computational fluid dynamics; Flow diversion; Flow quantification; Hemodynamics; X ray angiography

Indexed keywords

CEREBRAL ANEURYSMS; FLOW DIVERSION; FLOW QUANTIFICATION; HEMODYNAMIC CHANGES; LONG-TERM EFFECTS; PHYSIOLOGIC CONDITIONS; WALL SHEAR STRESS; X RAY ANGIOGRAPHY;

EID: 84891904277     PISSN: 20407939     EISSN: 20407947     Source Type: Journal    
DOI: 10.1002/cnm.2594     Document Type: Article
Times cited : (24)

References (16)
  • 1
    • 67651177821 scopus 로고    scopus 로고
    • Microsurgical management of incompletely coiled and recurrent aneurysms: trends, techniques, and observations on coil extrusion
    • Waldron JS, Halbach VV, Lawton MT. Microsurgical management of incompletely coiled and recurrent aneurysms: trends, techniques, and observations on coil extrusion. Neurosurgery 2009; 64(5):301-315.
    • (2009) Neurosurgery , vol.64 , Issue.5 , pp. 301-315
    • Waldron, J.S.1    Halbach, V.V.2    Lawton, M.T.3
  • 2
    • 14844337005 scopus 로고    scopus 로고
    • Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms
    • Lylyk P, Ferrario A, Pasbon B, Miranda C, Doroszuk G. Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. Journal of Neurosurgery 2005; 102(2):235-241.
    • (2005) Journal of Neurosurgery , vol.102 , Issue.2 , pp. 235-241
    • Lylyk, P.1    Ferrario, A.2    Pasbon, B.3    Miranda, C.4    Doroszuk, G.5
  • 4
    • 33745636588 scopus 로고    scopus 로고
    • Endovascular treatment of intracranial aneurysms with parent vessel reconstruction using balloon and self expandable stents
    • Szikora I., Berentei Z, Kulcsar Z, Barath K, Berez A, Bose A, Nyary I. Endovascular treatment of intracranial aneurysms with parent vessel reconstruction using balloon and self expandable stents. Acta Neurichirurgica 2006; 148: 711-723.
    • (2006) Acta Neurichirurgica , vol.148 , pp. 711-723
    • Szikora, I.1    Berentei, Z.2    Kulcsar, Z.3    Barath, K.4    Berez, A.5    Bose, A.6    Nyary, I.7
  • 5
    • 0031148733 scopus 로고    scopus 로고
    • Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity
    • Lieber BB, Stancampiano AP, Wakhloo AK. Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity. Annals of Biomedical Engineering 1997; 25(3):460-469.
    • (1997) Annals of Biomedical Engineering , vol.25 , Issue.3 , pp. 460-469
    • Lieber, B.B.1    Stancampiano, A.P.2    Wakhloo, A.K.3
  • 11
    • 84870941553 scopus 로고    scopus 로고
    • Effects of flow-diverting device oversizing on hemodynamics alteration in cerebral aneurysms
    • Mut F, Cebral JR. Effects of flow-diverting device oversizing on hemodynamics alteration in cerebral aneurysms. American Journal Of Neuroradiology 2012; 33(10):2010-2016.
    • (2012) American Journal Of Neuroradiology , vol.33 , Issue.10 , pp. 2010-2016
    • Mut, F.1    Cebral, J.R.2
  • 12
    • 17444420835 scopus 로고    scopus 로고
    • Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique
    • Cebral JR, Löhner R. Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique. IEEE Transactions in Medical Imaging 2005; 24(4):468-477.
    • (2005) IEEE Transactions in Medical Imaging , vol.24 , Issue.4 , pp. 468-477
    • Cebral, J.R.1    Löhner, R.2
  • 15
    • 20044391646 scopus 로고    scopus 로고
    • Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries
    • Ford MD., Alperin N, Lee SH, Holdsworth DW, Steinman DA. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiological Measurement 2005; 26: 477-488.
    • (2005) Physiological Measurement , vol.26 , pp. 477-488
    • Ford, M.D.1    Alperin, N.2    Lee, S.H.3    Holdsworth, D.W.4    Steinman, D.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.