메뉴 건너뛰기




Volumn 38, Issue 1, 2014, Pages 64-72

In Vitro Performance Analysis of a Novel Pulsatile Diagonal Pump in a Simulated Pediatric Mechanical Circulatory Support System

Author keywords

Diagonal pump; Pediatric mechanical circulatory support; Pediatrics; Pulsatile flow

Indexed keywords

HEMODYNAMICS; PULSATILE FLOW; PUMPS;

EID: 84891898991     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/aor.12181     Document Type: Article
Times cited : (12)

References (17)
  • 1
    • 84860704845 scopus 로고    scopus 로고
    • Facts and myths surrounding pediatric mechanical cardiovascular circulatory support research: a personal perspective
    • Ündar A. Facts and myths surrounding pediatric mechanical cardiovascular circulatory support research: a personal perspective. Artif Organs 2012;36:467-469.
    • (2012) Artif Organs , vol.36 , pp. 467-469
    • Ündar, A.1
  • 2
    • 80054104431 scopus 로고    scopus 로고
    • Mechanical circulatory support for end-stage heart failure in repaired and palliated congenital heart disease [Invited Review]
    • Clark JB, Pauliks LB, Myers JL, Ündar A. Mechanical circulatory support for end-stage heart failure in repaired and palliated congenital heart disease [Invited Review]. Curr Cardiol Rev 2011;7:102-109.
    • (2011) Curr Cardiol Rev , vol.7 , pp. 102-109
    • Clark, J.B.1    Pauliks, L.B.2    Myers, J.L.3    Ündar, A.4
  • 3
    • 84992905522 scopus 로고    scopus 로고
    • Heart transplantation for congenital heart disease [Invited Review]
    • Pauliks LB, Ündar A. Heart transplantation for congenital heart disease [Invited Review]. World J Pediatr Congenit Heart Surg 2011;2:603-608.
    • (2011) World J Pediatr Congenit Heart Surg , vol.2 , pp. 603-608
    • Pauliks, L.B.1    Ündar, A.2
  • 4
    • 40049111480 scopus 로고    scopus 로고
    • New devices for pediatric mechanical circulatory support [Invited Review]
    • Pauliks LB, Ündar A. New devices for pediatric mechanical circulatory support [Invited Review]. Curr Opin Cardiol 2008;23:91-96.
    • (2008) Curr Opin Cardiol , vol.23 , pp. 91-96
    • Pauliks, L.B.1    Ündar, A.2
  • 5
    • 84876363947 scopus 로고    scopus 로고
    • Current devices for pediatric extracorporeal life support and mechanical circulatory support systems in the United States
    • Undar A, Wang S. Current devices for pediatric extracorporeal life support and mechanical circulatory support systems in the United States. Biomed Mater Eng 2013;23:57-62.
    • (2013) Biomed Mater Eng , vol.23 , pp. 57-62
    • Undar, A.1    Wang, S.2
  • 7
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
    • Ündar A. Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. Artif Organs 2004;28:439-443.
    • (2004) Artif Organs , vol.28 , pp. 439-443
    • Ündar, A.1
  • 9
    • 83555176236 scopus 로고    scopus 로고
    • Venovenous extracorporeal membrane oxygenation for acute lung failure in adults
    • Schmid C, Philipp A, Hilker M, etal. Venovenous extracorporeal membrane oxygenation for acute lung failure in adults. J Heart Lung Transplant 2012;31:9-15.
    • (2012) J Heart Lung Transplant , vol.31 , pp. 9-15
    • Schmid, C.1    Philipp, A.2    Hilker, M.3
  • 10
    • 80052579088 scopus 로고    scopus 로고
    • First uses of a new diagonal pump in extracorporeal support systems for children and infants [German]
    • Tiedge S, Optenhöfel J. First uses of a new diagonal pump in extracorporeal support systems for children and infants [German]. Kardiotechnik 2011;20:72-76.
    • (2011) Kardiotechnik , vol.20 , pp. 72-76
    • Tiedge, S.1    Optenhöfel, J.2
  • 11
    • 84872367905 scopus 로고    scopus 로고
    • Novel pulsatile diagonal pump for pediatric extracorporeal life support system
    • Wang S, Kunselman AR, Ündar A. Novel pulsatile diagonal pump for pediatric extracorporeal life support system. Artif Organs 2013;37:37-47.
    • (2013) Artif Organs , vol.37 , pp. 37-47
    • Wang, S.1    Kunselman, A.R.2    Ündar, A.3
  • 12
    • 84891896251 scopus 로고    scopus 로고
    • Impact of pulsatile flow on hemodynamic energy in a Medos Deltastream DP3 pediatric extracorporeal life support system
    • doi: 10.1111/aor.12117.
    • Krawiec C, Wang S, Kunselman AR, Ündar A. Impact of pulsatile flow on hemodynamic energy in a Medos Deltastream DP3 pediatric extracorporeal life support system. Artif Organs 2013. doi: 10.1111/aor.12117.
    • (2013) Artif Organs
    • Krawiec, C.1    Wang, S.2    Kunselman, A.R.3    Ündar, A.4
  • 16
    • 28444472363 scopus 로고    scopus 로고
    • Synchronously counterpulsating extracorporeal life support enhances myocardial working conditions regardless of systemic perfusion pressure
    • Reesink KD, Sauren LD, Dekker AL, etal. Synchronously counterpulsating extracorporeal life support enhances myocardial working conditions regardless of systemic perfusion pressure. Eur J Cardiothorac Surg 2005;28:790-796.
    • (2005) Eur J Cardiothorac Surg , vol.28 , pp. 790-796
    • Reesink, K.D.1    Sauren, L.D.2    Dekker, A.L.3
  • 17
    • 70149109186 scopus 로고    scopus 로고
    • Initial results of clinical trial with a new left ventricular assist device (LVAD) providing synchronous pulsatile flow
    • Gazzoli F, Viganò M, Pagani F, etal. Initial results of clinical trial with a new left ventricular assist device (LVAD) providing synchronous pulsatile flow. Int J Artif Organs 2009;32:344-353.
    • (2009) Int J Artif Organs , vol.32 , pp. 344-353
    • Gazzoli, F.1    Viganò, M.2    Pagani, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.