메뉴 건너뛰기




Volumn 50, Issue 1, 2014, Pages 27-31

Dräger VN500's oscillatory performance has a frequency-dependent threshold

Author keywords

high frequency oscillatory ventilation; infant; mechanical ventilation; neonate

Indexed keywords

AIRWAY; AIRWAY PRESSURE; ARTICLE; HIGH FREQUENCY OSCILLATION; HIGH FREQUENCY VENTILATOR; HUMAN; HUMIDITY; INFANT; LUNG; OSCILLATOR; PRIORITY JOURNAL; TIDAL VOLUME;

EID: 84891887722     PISSN: 10344810     EISSN: 14401754     Source Type: Journal    
DOI: 10.1111/jpc.12398     Document Type: Article
Times cited : (16)

References (12)
  • 1
    • 0037194696 scopus 로고    scopus 로고
    • Ventilation with small tidal volumes
    • Slutsky AS, Drazen JM,. Ventilation with small tidal volumes. N. Engl. J. Med. 2002; 347: 630-631.
    • (2002) N. Engl. J. Med. , vol.347 , pp. 630-631
    • Slutsky, A.S.1    Drazen, J.M.2
  • 2
    • 0031957576 scopus 로고    scopus 로고
    • Effect of the TI/TE ratio on mean intratracheal pressure in high-frequency oscillatory ventilation
    • Thome U, Pohlandt F,. Effect of the TI/TE ratio on mean intratracheal pressure in high-frequency oscillatory ventilation. J. Appl. Physiol. 1998; 84: 1520-1527.
    • (1998) J. Appl. Physiol. , vol.84 , pp. 1520-1527
    • Thome, U.1    Pohlandt, F.2
  • 4
    • 0025040482 scopus 로고
    • Proximal, tracheal, and alveolar pressures during high-frequency oscillatory ventilation in a normal rabbit model
    • Gerstmann DR, Fouke JM, Winter DC, Taylor AF, A deLemos R,. Proximal, tracheal, and alveolar pressures during high-frequency oscillatory ventilation in a normal rabbit model. Pediatr. Res. 1990; 28: 367-373.
    • (1990) Pediatr. Res. , vol.28 , pp. 367-373
    • Gerstmann, D.R.1    Fouke, J.M.2    Winter, D.C.3    Taylor, A.F.4    Delemos R, A.5
  • 5
    • 0030615188 scopus 로고    scopus 로고
    • Assessment of high-frequency neonatal ventilator performances
    • et al.
    • Jouvet P, Hubert P, Isabey D, et al. Assessment of high-frequency neonatal ventilator performances. Intensive Care Med. 1997; 23: 208-213.
    • (1997) Intensive Care Med. , vol.23 , pp. 208-213
    • Jouvet, P.1    Hubert, P.2    Isabey, D.3
  • 6
    • 0034780524 scopus 로고    scopus 로고
    • Reliable tidal volume estimates at the airway opening with an infant monitor during high-frequency oscillatory ventilation
    • Scalfaro P, Pillow JJ, Sly PD, Cotting J,. Reliable tidal volume estimates at the airway opening with an infant monitor during high-frequency oscillatory ventilation. Crit. Care Med. 2001; 29: 1925-1930.
    • (2001) Crit. Care Med. , vol.29 , pp. 1925-1930
    • Scalfaro, P.1    Pillow, J.J.2    Sly, P.D.3    Cotting, J.4
  • 7
    • 0031746090 scopus 로고    scopus 로고
    • Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators
    • Hatcher D, Watanabe H, Ashbury T, Vincent S, Fisher J, Froese A,. Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators. Crit. Care Med. 1998; 26: 1081-1088.
    • (1998) Crit. Care Med. , vol.26 , pp. 1081-1088
    • Hatcher, D.1    Watanabe, H.2    Ashbury, T.3    Vincent, S.4    Fisher, J.5    Froese, A.6
  • 9
    • 0021340725 scopus 로고
    • Mechanisms of gas transport during ventilation by high-frequency oscillation
    • Chang HK,. Mechanisms of gas transport during ventilation by high-frequency oscillation. J. Appl. Physiol. 1984; 56: 553-563.
    • (1984) J. Appl. Physiol. , vol.56 , pp. 553-563
    • Chang, H.K.1
  • 10
    • 65749316343 scopus 로고
    • High frequency ventilation
    • Froese AB,. High frequency ventilation. Can. J. Anaesth. 1987; 34: 37-40.
    • (1987) Can. J. Anaesth. , vol.34 , pp. 37-40
    • Froese, A.B.1
  • 11
    • 0027935397 scopus 로고
    • Understanding the pressure cost of ventilation: Why does high-frequency ventilation work?
    • Venegas JG, Fredberg JJ,. Understanding the pressure cost of ventilation: why does high-frequency ventilation work? Crit. Care Med. 1994; 22: S49.
    • (1994) Crit. Care Med. , vol.22
    • Venegas, J.G.1    Fredberg, J.J.2
  • 12
    • 33846807068 scopus 로고    scopus 로고
    • Trends in use and outcome of newborn infants treated with high frequency ventilation in Australia and New Zealand, 1996-2003
    • Tingay DG, Mills JF, Morley CJ, Pellicano A, Dargaville PA,. Trends in use and outcome of newborn infants treated with high frequency ventilation in Australia and New Zealand, 1996-2003. J. Paediatr. Child Health 2007; 43: 160-166.
    • (2007) J. Paediatr. Child Health , vol.43 , pp. 160-166
    • Tingay, D.G.1    Mills, J.F.2    Morley, C.J.3    Pellicano, A.4    Dargaville, P.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.