메뉴 건너뛰기




Volumn 28, Issue 1, 2014, Pages 6-9

Variation in the femoral bow: A novel high-throughput analysis of 3922 femurs on cross-sectional imaging

Author keywords

Computed tomography; Ethnicity; Femoral curvature; Femur; Gender; Intramedullary implant

Indexed keywords

ADULT; AFRICAN AMERICAN; ALGORITHM; ANATOMIC LANDMARK; ARTICLE; ASIAN AMERICAN; BODY MASS; BODY POSITION; BONE BOWING; BONE LENGTH; BONE RADIOGRAPHY; CAUCASIAN; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL THICKNESS (BONE); ETHNIC GROUP; ETHNICITY; FEMALE; HIGH THROUGHPUT SCREENING; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; PICTURE ARCHIVING AND COMMUNICATION SYSTEM; PRIORITY JOURNAL; RACE DIFFERENCE; RETROSPECTIVE STUDY; SEX DIFFERENCE; AGED; ANATOMY; ANTHROPOMETRY; FEMUR; RADIOGRAPHY;

EID: 84891826032     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0b013e31829ff3c9     Document Type: Article
Times cited : (66)

References (10)
  • 1
    • 4444374995 scopus 로고    scopus 로고
    • Mismatch of current intramedullary nails with the anterior bow of the femur
    • Egol KA, Chang EY, Cvitkovic J, et al. Mismatch of current intramedullary nails with the anterior bow of the femur. J Orthop Trauma. 2004;18: 410-415.
    • (2004) J Orthop Trauma. , vol.18 , pp. 410-415
    • Egol, K.A.1    Chang, E.Y.2    Cvitkovic, J.3
  • 2
    • 0023268755 scopus 로고
    • Curvature of the femur and the proximal entry point for an intramedullary rod
    • Harper MC, Carson WL. Curvature of the femur and the proximal entry point for an intramedullary rod. Clin Orthop Relat Res. 1987;220:155-161.
    • (1987) Clin Orthop Relat Res. , vol.220 , pp. 155-161
    • Harper, M.C.1    Carson, W.L.2
  • 3
    • 0024046059 scopus 로고
    • Form and dimension of the bone marrow cavity of the human femur with reference to the fit of intramedullary implants [in German]
    • Zuber K, Schneider E, Eulenberger J, et al. Form and dimension of the bone marrow cavity of the human femur with reference to the fit of intramedullary implants [in German]. Unfallchirurg. 1988;91:314-319.
    • (1988) Unfallchirurg. , vol.91 , pp. 314-319
    • Zuber, K.1    Schneider, E.2    Eulenberger, J.3
  • 4
    • 0033159054 scopus 로고    scopus 로고
    • Anterior femoral curvature revisited: Race assessment from the femur
    • Ballard ME, Trudell MB. Anterior femoral curvature revisited: race assessment from the femur. J Forensic Sci. 1999;44:700-707.
    • (1999) J Forensic Sci. , vol.44 , pp. 700-707
    • Ballard, M.E.1    Trudell, M.B.2
  • 5
    • 0036839277 scopus 로고    scopus 로고
    • Temporal trends in femoral curvature and length in medieval and modern Scotland
    • Bruns W, Bruce M, Prescott G, et al. Temporal trends in femoral curvature and length in medieval and modern Scotland. Am J Phys Anthropol. 2002;119:224-230.
    • (2002) Am J Phys Anthropol. , vol.119 , pp. 224-230
    • Bruns, W.1    Bruce, M.2    Prescott, G.3
  • 6
    • 30344459122 scopus 로고    scopus 로고
    • The comparison of femoral curves and curves of contemporary intramedullary nails
    • Harma A, Germen B, Karakas HM, et al. The comparison of femoral curves and curves of contemporary intramedullary nails. Surg Radiol Anat. 2005;27:502-506.
    • (2005) Surg Radiol Anat. , vol.27 , pp. 502-506
    • Harma, A.1    Germen, B.2    Karakas, H.M.3
  • 7
    • 0030058597 scopus 로고    scopus 로고
    • Geometric mismatch of the Gamma nail to the Chinese femur
    • Leung KS, Procter P, Robioneck B, et al. Geometric mismatch of the Gamma nail to the Chinese femur. Clin Orthop Relat Res. 1996; 323:42-48.
    • (1996) Clin Orthop Relat Res. , vol.323 , pp. 42-48
    • Leung, K.S.1    Procter, P.2    Robioneck, B.3
  • 8
    • 0027223342 scopus 로고
    • Measurement of carpal bone geometry by computer analysis of three-dimensional CT images
    • Viegas SF, Hillman GR, Elder K, et al. Measurement of carpal bone geometry by computer analysis of three-dimensional CT images. J Hand Surg Am. 1993;18:341-349.
    • (1993) J Hand Surg Am. , vol.18 , pp. 341-349
    • Viegas, S.F.1    Hillman, G.R.2    Elder, K.3
  • 9
    • 85045417337 scopus 로고    scopus 로고
    • Mismatch of current intramedullary nails with the anterior bow of the femur [comment]
    • Zirkle L Jr. Mismatch of current intramedullary nails with the anterior bow of the femur [comment]. J Orthop Trauma. 2005;19:145.
    • (2005) J Orthop Trauma. , vol.19 , pp. 145
    • Zirkle Jr., L.1
  • 10
    • 84868190011 scopus 로고    scopus 로고
    • United States Census Bureau. Accessed April 22
    • United States Census Bureau. State and country quick facts. Available at: http://quickfacts.census.gov/qfd/states/26000.html. Accessed April 22, 2013.
    • (2013) State and Country Quick Facts


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.