메뉴 건너뛰기




Volumn 477, Issue 1, 2013, Pages

Monitoring heart rate variability online using e-health oriented 3G mobile telephone services

Author keywords

Cardiac Arrhythmia; FLEEM; Mobile phone; Prevention; Tool

Indexed keywords

BLOOD PRESSURE; CELLULAR TELEPHONES; DIAGNOSIS; DISEASES; HEART; MOBILE PHONES; RISK PERCEPTION; TELEPHONE SETS; TOOLS;

EID: 84891781495     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/477/1/012036     Document Type: Conference Paper
Times cited : (6)

References (13)
  • 1
    • 0029928495 scopus 로고    scopus 로고
    • Chairman of Writing Committee of Task Force of the European Society of Cardiology and the North American Society of Pacing Electrophysiology): Heart Rate Variability
    • Malik, M et al 1996 (Chairman of Writing Committee of Task Force of the European Society of Cardiology and the North American Society of Pacing Electrophysiology): Heart Rate Variability: Standards Meas., Physiological Interpretation, Clinical Use. Circulation 93 1043-1065
    • (1996) Standards Meas., Physiological Interpretation, Clinical Use. Circulation , vol.93 , pp. 1043-1065
    • Malik, M.1
  • 2
    • 0029928495 scopus 로고    scopus 로고
    • Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
    • 10.1161/01.CIR.93.5.1043 0009-7322
    • Camm A J, M Malik et al 1996 Heart rate variability: standards of measurement, physiological interpretation, and clinical use Circulation 93 (5) 1043-1065
    • (1996) Circulation , vol.93 , Issue.5 , pp. 1043-1065
    • Camm, A.J.1    Malik, M.2
  • 5
    • 0141509903 scopus 로고    scopus 로고
    • Comparison of detrended fluctuations and spectral analysis for heart rate variability in sleep and sleep apnea
    • Penzel, T, Kantelhardt, JW, Grote, L, Peter, JH and Bunde, A Comparison of detrended fluctuations and spectral analysis for heart rate variability in sleep and sleep apnea IEEE Trans. Biomedical Eng. 50 1143-1151
    • IEEE Trans. Biomedical Eng. , vol.50 , pp. 1143-1151
    • Penzel, T.1    Kantelhardt, J.W.2    Grote, L.3    Peter, J.H.4    Bunde, A.5
  • 7
    • 34247554783 scopus 로고    scopus 로고
    • Comparison of the ratio of the standard deviation of the r-r interval and the root mean squared successivedifferences (SD/rMSSD) to the low frequency-to-high frequency (LF/HF) ratio in a patient population and normal healthy controls
    • Sollers J J, T W Buchanan, S M Mowrer, L K Hill and J F Thayer 2007 Comparison of the ratio of the standard deviation of the r-r interval and the root mean squared successivedifferences (SD/rMSSD) to the low frequency-to-high frequency (LF/HF) ratio in a patient population and normal healthy controls Biomedical Sci. Instrum. 43 158-163
    • (2007) Biomedical Sci. Instrum. , vol.43 , pp. 158-163
    • Sollers, J.J.1    Buchanan, T.W.2    Mowrer, S.M.3    Hill, L.K.4    Thayer, J.F.5
  • 8
    • 84891808349 scopus 로고    scopus 로고
    • Monitoring System of Assessment of Energy Expenditure to Human in Free-living Condition by Mean of Information and Communication Technologies
    • Lopez, LJR and Goroso DG 2010 Monitoring System of Assessment of Energy Expenditure to Human in Free-living Condition by Mean of Information and Communication Technologies Proc. Med-e-Tel, Luxembourg (Lu) 550-555 ISBN 2179-3220
    • (2010) Proc. Med-e-Tel, Luxembourg (Lu) , pp. 550-555
    • Lopez, L.1    Goroso, D.G.2
  • 9
    • 84891756499 scopus 로고    scopus 로고
    • Sensor Network for Assessment of Energy Expenditure design based on Android
    • 1680-0737
    • Lopez L J R, DG Goroso e LM Battistella 2011 Sensor Network for Assessment of Energy Expenditure design based on Android IFMBE Proc. 3 130-134
    • (2011) IFMBE Proc. , vol.3 , pp. 130-134
    • Lopez, L.J.R.1    Goroso, L.M.2    Battistella, E.D.G.3
  • 10
    • 84891771015 scopus 로고    scopus 로고
    • Relationship between triaxial stand-alone and embedded accelerometers in a mobile phone for Healthcare Applications
    • Lopez L J R, DG Goroso e LM Battistella 2012 Relationship between triaxial stand-alone and embedded accelerometers in a mobile phone for Healthcare Applications Medical Engnnering Phys.
    • (2012) Medical Engnnering Phys.
    • Lopez, L.J.R.1    Goroso, L.M.2    Battistella, E.D.G.3
  • 11
    • 0019827638 scopus 로고
    • Power spectrum analysis of heart rate fluctuations: A quantitative probe of beat-to-beat cardiovascular control
    • 10.1126/science.6166045 0036-8075
    • Akselrod, S, Gordon, D, Ubel, FA, Shannon, DC, Berger, AC and Cohen, RJ 1981 Power spectrum analysis of heart rate fluctuations: a quantitative probe of beat-to-beat cardiovascular control Science 213 220-222
    • (1981) Science , vol.213 , Issue.4504 , pp. 220-222
    • Akselrod, S.1    Gordon, D.2    Ubel, F.A.3    Shannon, D.C.4    Berger, A.C.5    Cohen, R.J.6
  • 12
    • 0036703124 scopus 로고    scopus 로고
    • Heart rate variability as a clinical tool
    • 1129-471X
    • Malliani A, Montano N 2002 Heart rate variability as a clinical tool Ital Heart J. 3 (8) 439-45
    • (2002) Ital Heart J. , vol.3 , Issue.8 , pp. 439-445
    • Malliani, A.1    Montano, N.2
  • 13
    • 56949084180 scopus 로고    scopus 로고
    • Heart rate variability explored in the frequency domain: A tool to investigate the link between heart and behavior
    • 10.1016/j.neubiorev.2008.07.006 0149-7634
    • Montano N et al 2009 Heart rate variability explored in the frequency domain: a tool to investigate the link between heart and behavior Neurosci Biobehav Rev. 33 (2) 71-80
    • (2009) Neurosci Biobehav Rev. , vol.33 , Issue.2 , pp. 71-80
    • Montano, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.